{"title":"Lux Meters","description":"Digital lux meters and light meters for illumination measurement in workplaces and studios.","products":[{"product_id":"lutron-lx-101a-digital-lux-meter","title":"Lutron LX-101A Digital Lux Meter","description":"\u003cdiv class=\"powr-chat\" id=\"1abb102c_1753877895\"\u003e\u003c\/div\u003e\n\u003ch2\u003eLutron LX-101A Digital Lux Meter\u003c\/h2\u003e\n\u003ch2\u003eLutron LX-101A Digital Lux Meter: Professional Light Measurement Device\u003c\/h2\u003e\nThe Lutron LX-101A Digital Lux Meter is a precision instrument designed for accurate measurement of light intensity across various professional applications. This compact, portable device provides reliable illumination readings to ensure optimal lighting conditions in workplaces, studios, educational institutions, and industrial environments.\n\u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy Measurement\u003c\/strong\u003e - Provides precise light intensity readings in lux units\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDigital Display\u003c\/strong\u003e - Clear, easy-to-read LCD screen for instant measurement results\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePortable Design\u003c\/strong\u003e - Lightweight, compact construction for convenient field use\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSimple Operation\u003c\/strong\u003e - User-friendly interface requires minimal training\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProfessional Calibration\u003c\/strong\u003e - Factory calibrated for reliable, consistent readings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range\u003c\/strong\u003e - Suitable for various lighting conditions from dim to bright environments\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuick Response Time\u003c\/strong\u003e - Rapid readings for efficient light assessment\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDurable Construction\u003c\/strong\u003e - Built to withstand regular professional use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLutron LX-101A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLux (lx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCIE photopic curve (human eye response)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon photodiode with filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDurable plastic housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003ch4\u003ePhotography \u0026amp; Videography Lutron LX-101A Digital Lux Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLighting Setup\u003c\/strong\u003e - Ensure optimal light levels for photography and video recording\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStudio Calibration\u003c\/strong\u003e - Maintain consistent lighting conditions for professional shooting\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOn-location Assessment\u003c\/strong\u003e - Quickly evaluate ambient light before setup\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProduct Photography\u003c\/strong\u003e - Achieve precise lighting for product showcase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWorkplace Safety \u0026amp; Compliance Lutron LX-101A Digital Lux Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOSHA Compliance\u003c\/strong\u003e - Verify illumination meets workplace safety standards\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOffice Lighting\u003c\/strong\u003e - Ensure optimal lighting for employee comfort and productivity\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEmergency Lighting\u003c\/strong\u003e - Test adequacy of emergency illumination systems\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBuilding Inspections\u003c\/strong\u003e - Document lighting conditions for regulatory compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEducational \u0026amp; Research Applications Lutron LX-101A Digital Lux Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eScience Experiments\u003c\/strong\u003e - Measure light intensity for plant growth studies\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eClassroom Environment\u003c\/strong\u003e - Assess lighting adequacy for educational settings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLaboratory Work\u003c\/strong\u003e - Monitor light conditions for experiments and research\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eField Studies\u003c\/strong\u003e - Portable solution for environmental light measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIndustrial \u0026amp; Commercial Use Lutron LX-101A Digital Lux Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eManufacturing Quality Control\u003c\/strong\u003e - Ensure proper lighting for inspection areas\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRetail Environments\u003c\/strong\u003e - Optimize display and merchandise lighting\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eArchitectural Assessments\u003c\/strong\u003e - Evaluate lighting design in buildings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnergy Efficiency\u003c\/strong\u003e - Support lighting system optimization for energy savings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose the Lutron LX-101A?\u003c\/h3\u003e\n\u003ch4\u003eTrusted Brand Quality Lutron LX-101A Digital Lux Meter\u003c\/h4\u003e\nLutron is a recognized leader in measurement instrumentation, known for producing reliable, accurate devices for professional use. The LX-101A represents Lutron's commitment to quality and precision in every measurement tool they manufacture.\n\u003ch4\u003eUser-Friendly Design Lutron LX-101A Digital Lux Meter\u003c\/h4\u003e\nDesigned with simplicity in mind, the LX-101A provides instant, clear readings without complex setup or calibration processes. This allows professionals from various fields to use the device with minimal training, making it accessible for both specialists and occasional users.\n\u003ch4\u003eVersatile Application Lutron LX-101A Digital Lux Meter\u003c\/h4\u003e\nFrom photography studios to industrial workplaces, educational institutions to architectural assessments, the LX-101A serves a wide range of applications where precise light measurement is essential. Its portable nature makes it convenient for both fixed location monitoring and field work.\n\u003ch4\u003eCost-Effective Solution Lutron LX-101A Digital Lux Meter\u003c\/h4\u003e\nThe Lutron LX-101A offers professional-grade light measurement capabilities at an accessible price point, making it an excellent investment for businesses, educational institutions, and individual professionals who need reliable illumination data without the cost of more complex photometric equipment.\n\u003ch3\u003eOperating Instructions Lutron LX-101A Digital Lux Meter\u003c\/h3\u003e\n\u003col\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePreparation\u003c\/strong\u003e - Remove the protective cover from the light sensor before use\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePower On\u003c\/strong\u003e - Press the power button to activate the meter\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePositioning\u003c\/strong\u003e - Place the sensor in the area where you want to measure light intensity\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eReading\u003c\/strong\u003e - View the measurement directly on the LCD display in lux units\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompletion\u003c\/strong\u003e - Power off the device and replace the sensor cover when finished\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMaintenance Tips Lutron LX-101A Digital Lux Meter\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003eAlways replace the protective sensor cover when not in use to prevent dust accumulation and damage\u003c\/li\u003e\n \t\u003cli\u003eStore in a dry, cool place away from direct sunlight when not in use\u003c\/li\u003e\n \t\u003cli\u003eClean the sensor surface gently with a soft, dry cloth if necessary\u003c\/li\u003e\n \t\u003cli\u003eReplace batteries promptly when the low battery indicator appears\u003c\/li\u003e\n \t\u003cli\u003eAvoid exposing the sensor to extremely bright light sources that could potentially damage the photodiode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Light Levels Lutron LX-101A Digital Lux Meter\u003c\/h3\u003e\nThe Lutron LX-101A helps you verify that illumination meets recommended standards for different environments:\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003cth\u003eRecommended Illuminance (lux)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffice Workspaces\u003c\/td\u003e\n\u003ctd\u003e300-500 lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecision Manufacturing\u003c\/td\u003e\n\u003ctd\u003e1000-2000 lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorridors and Hallways\u003c\/td\u003e\n\u003ctd\u003e100-200 lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClassrooms\u003c\/td\u003e\n\u003ctd\u003e300-500 lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Areas\u003c\/td\u003e\n\u003ctd\u003e500-700 lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetailed Drawing\/Design\u003c\/td\u003e\n\u003ctd\u003e1000-1500 lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat's Included Lutron LX-101A Digital Lux Meter\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003eLutron LX-101A Digital Lux Meter\u003c\/li\u003e\n \t\u003cli\u003eLight sensor with protective cover\u003c\/li\u003e\n \t\u003cli\u003eBatteries\u003c\/li\u003e\n \t\u003cli\u003eUser manual with operating instructions\u003c\/li\u003e\n \t\u003cli\u003eProtective carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAbout Lutron Electronic Lutron LX-101A Digital Lux Meter\u003c\/h3\u003e\nLutron Electronic Enterprise Co., Ltd. is a respected manufacturer of precision measurement instruments. With decades of experience in developing reliable testing equipment, Lutron has established a global reputation for producing high-quality meters for electrical, environmental, and industrial applications. Their products are widely used by professionals who require accurate measurements for critical decision-making.\n\u003ch3\u003eSummary Lutron LX-101A Digital Lux Meter\u003c\/h3\u003e\nThe Lutron LX-101A Digital Lux Meter is an essential tool for professionals who need accurate light intensity measurements. With its user-friendly design, reliable performance, and versatile applications, this device provides valuable data for optimizing lighting conditions across various environments. Whether you're a photographer setting up studio lighting, a safety inspector verifying workplace illumination, or a researcher monitoring light conditions, the LX-101A delivers the precision and convenience you need for professional light measurement.","brand":"Lutron","offers":[{"title":"Default Title","offer_id":51460961992950,"sku":"LUT-LUX-101A","price":4130.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Lutron_LX-101A_Digital_Lux_Meter__27126.1754460171.386.513_ba915b52-de42-4ed6-b8f5-438a044e043c.jpg?v=1786598829"},{"product_id":"lutron-lx-102-digital-light-meter","title":"Lutron LX-102 Digital Light Meter","description":"\u003cdiv class=\"powr-chat\" id=\"1abb102c_1753877895\"\u003e\u003c\/div\u003e\n\u003ch2\u003eLutron LX-102 Digital Light Meter\u003c\/h2\u003e\n\u003ch2\u003eLutron LX-102 Digital Light Meter with Analog Output\u003c\/h2\u003e\nThe Lutron LX-102 Digital Light Meter is a professional-grade illuminance measurement device designed for precise light intensity readings across various applications. This ISO-9001, CE, and IEC1010 certified instrument offers exceptional accuracy and reliability for photographers, safety inspectors, architects, and researchers who require dependable light level measurements.\n\u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProfessional Certification\u003c\/strong\u003e - ISO-9001, CE, and IEC1010 certified for guaranteed quality and safety\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDual Measurement Units\u003c\/strong\u003e - Measures in both Lux (0-50,000) and Foot-candle (0-5,000)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMulti-Range Capability\u003c\/strong\u003e - Three selectable ranges for precise readings across lighting conditions\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy\u003c\/strong\u003e - ±5% accuracy for reliable light intensity measurements\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSeparate Light Sensor\u003c\/strong\u003e - Detachable sensor for optimal positioning and measurement flexibility\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eC.I.E. Photopic Compliance\u003c\/strong\u003e - Exclusive photodiode \u0026amp; color correction filter matching human eye response\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCOS Correction Factor\u003c\/strong\u003e - Ensures accurate readings at different light angles\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Hold Function\u003c\/strong\u003e - Freezes measurements on display for easy recording\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAnalog Output\u003c\/strong\u003e - 0.1 mV\/digit (max 200.0 mV) for connecting to recording devices\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFast Response\u003c\/strong\u003e - Approximately 0.4 second sampling time for quick readings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eClear LCD Display\u003c\/strong\u003e - 13mm (0.5\") digits visible even in bright ambient light\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLow Power Consumption\u003c\/strong\u003e - Approximately DC 2 mA for extended battery life\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLow Battery Indicator\u003c\/strong\u003e - Built-in warning system when replacement is needed\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLSI-Circuit Design\u003c\/strong\u003e - High reliability and durability for professional use\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Lightweight\u003c\/strong\u003e - Only 220g (0.52 LB) with batteries for portable convenience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Lutron LX-102 Digital Light Meter\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLutron LX-102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 mm (0.5\") LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLux, Foot-candle, Data hold, Analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLux: 0-2,000 \/ 0-20,000 \/ 0-50,000 (3 ranges)\nFoot-candle: 0-200 \/ 0-2,000 \/ 0-5,000 (3 ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLux: 1 Lux \/ 10 Lux \/ 100 Lux\nFoot-candle: 0.1 Ft-cd \/ 1 Ft-cd \/ 10 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(5% + 2 digits) at 23°C ± 5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZero Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndication of \"1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.4 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Structure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExclusive photodiode \u0026amp; color correction filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\/1 digit, Max. 200.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 80% R.H.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 9V battery, 006P, MN1604 (PP3) or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately DC 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain Instrument: 163 × 70 × 30 mm (6.4 × 2.8 × 1.2 inch)\nSensor probe: 82 × 55 × 7 mm (3.2 × 2.2 × 0.3 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220g (0.52 LB) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstruction manual (1 PC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO-9001, CE, IEC1010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMeasurement Ranges \u0026amp; Accuracy Lutron LX-102 Digital Light Meter\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eLux Measurement\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eFoot-candle Measurement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2,000 Lux\u003c\/td\u003e\n\u003ctd\u003e1 Lux\u003c\/td\u003e\n\u003ctd\u003e±(5% + 2d)\u003c\/td\u003e\n\u003ctd\u003e200 Ft-candle\u003c\/td\u003e\n\u003ctd\u003e0.1 Ft-candle\u003c\/td\u003e\n\u003ctd\u003e±(5% + 2d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20,000 Lux\u003c\/td\u003e\n\u003ctd\u003e10 Lux\u003c\/td\u003e\n\u003ctd\u003e±(5% + 2d)\u003c\/td\u003e\n\u003ctd\u003e2,000 Ft-candle\u003c\/td\u003e\n\u003ctd\u003e1 Ft-candle\u003c\/td\u003e\n\u003ctd\u003e±(5% + 2d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50,000 Lux\u003c\/td\u003e\n\u003ctd\u003e100 Lux\u003c\/td\u003e\n\u003ctd\u003e±(5% + 2d)\u003c\/td\u003e\n\u003ctd\u003e5,000 Ft-candle\u003c\/td\u003e\n\u003ctd\u003e10 Ft-candle\u003c\/td\u003e\n\u003ctd\u003e±(5% + 2d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003ch4\u003ePhotography \u0026amp; Videography Lutron LX-102 Digital Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStudio Lighting Setup\u003c\/strong\u003e - Precisely measure illumination for optimal exposure settings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLocation Assessment\u003c\/strong\u003e - Evaluate ambient lighting conditions before shoots\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCinematography\u003c\/strong\u003e - Ensure consistent lighting across film and video sets\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProduct Photography\u003c\/strong\u003e - Maintain standardized lighting for product catalogs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIndustrial \u0026amp; Workplace Safety\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRegulatory Compliance\u003c\/strong\u003e - Verify illumination meets OSHA and other safety standards\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProduction Areas\u003c\/strong\u003e - Ensure proper lighting for manufacturing and assembly\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOffice Environments\u003c\/strong\u003e - Optimize lighting for employee productivity and comfort\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuality Control Stations\u003c\/strong\u003e - Confirm adequate lighting for inspection processes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eArchitectural \u0026amp; Environmental Design\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBuilding Commissioning\u003c\/strong\u003e - Verify lighting installations meet design specifications\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnergy Audits\u003c\/strong\u003e - Identify opportunities for lighting optimization and energy savings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eExhibition Spaces\u003c\/strong\u003e - Set appropriate lighting levels for museums and galleries\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLandscape Lighting\u003c\/strong\u003e - Measure illumination for outdoor architectural features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eResearch \u0026amp; Education\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eScientific Research\u003c\/strong\u003e - Monitor light conditions for experiments and studies\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHorticulture\u003c\/strong\u003e - Measure light intensity for plant growth research\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEducational Facilities\u003c\/strong\u003e - Ensure proper illumination in classrooms and laboratories\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnvironmental Studies\u003c\/strong\u003e - Track natural and artificial light levels in various settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Features Explained\u003c\/h3\u003e\n\u003ch4\u003eProfessional Sensor Technology Lutron LX-102 Digital Light Meter\u003c\/h4\u003e\nThe LX-102 employs an exclusive photodiode with specialized color correction filter that precisely matches the C.I.E. photopic curve—the international standard for human eye light response. This ensures the meter measures light intensity as it would be perceived by the human eye rather than just physical radiation, providing more relevant readings for practical applications.\n\nThe sensor's COS correction factor standardization further enhances accuracy by accounting for the angle at which light strikes the sensor surface. This means measurements remain consistent even when light comes from different directions, not just perpendicular to the sensor.\n\u003ch4\u003eDetachable Sensor Design Lutron LX-102 Digital Light Meter\u003c\/h4\u003e\nThe separate light sensor design offers significant advantages over fixed-sensor meters:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFlexible Positioning\u003c\/strong\u003e - Place the sensor exactly where measurement is needed while keeping the display visible\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eReduced Interference\u003c\/strong\u003e - Prevent your body from casting shadows or reflecting light onto the measurement area\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAccess to Difficult Locations\u003c\/strong\u003e - Measure in tight spaces or awkward positions while easily reading the display\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMore Accurate Results\u003c\/strong\u003e - Position the sensor for optimal readings without compromising visibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eData Hold \u0026amp; Analog Output Lutron LX-102 Digital Light Meter\u003c\/h4\u003e\nThe data hold function allows users to freeze the current reading on the display, making it easier to record measurements in challenging positions or when taking multiple readings in sequence.\n\nFor continuous monitoring or recording of light conditions over time, the LX-102 provides an analog output signal (0.1 mV per digit, maximum 200.0 mV) that can be connected to data loggers, chart recorders, or other recording devices. This feature is particularly valuable for:\n\u003cul\u003e\n \t\u003cli\u003eLong-term environmental studies\u003c\/li\u003e\n \t\u003cli\u003eLight variation analysis throughout the day\u003c\/li\u003e\n \t\u003cli\u003eAutomated quality control processes\u003c\/li\u003e\n \t\u003cli\u003eResearch requiring continuous light level documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Light Levels Lutron LX-102 Digital Light Meter\u003c\/h3\u003e\nThe Lutron LX-102 Digital Light Meter helps verify that illumination meets recommended standards for different environments:\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\/Activity\u003c\/th\u003e\n\u003cth\u003eRecommended Illuminance (Lux)\u003c\/th\u003e\n\u003cth\u003eFoot-candle Equivalent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Staircases, Storage Areas\u003c\/td\u003e\n\u003ctd\u003e50-100 Lux\u003c\/td\u003e\n\u003ctd\u003e5-10 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimple Orientation, Short Visits\u003c\/td\u003e\n\u003ctd\u003e100-150 Lux\u003c\/td\u003e\n\u003ctd\u003e10-15 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Areas with Occasional Visual Tasks\u003c\/td\u003e\n\u003ctd\u003e150-250 Lux\u003c\/td\u003e\n\u003ctd\u003e15-25 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarehouses, Homes, Theaters, Archives\u003c\/td\u003e\n\u003ctd\u003e250-350 Lux\u003c\/td\u003e\n\u003ctd\u003e25-35 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Offices, Classrooms, Supermarkets\u003c\/td\u003e\n\u003ctd\u003e350-500 Lux\u003c\/td\u003e\n\u003ctd\u003e35-50 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratories, Technical Drawing, Precision Work\u003c\/td\u003e\n\u003ctd\u003e500-750 Lux\u003c\/td\u003e\n\u003ctd\u003e50-75 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual Tasks of Medium Contrast\u003c\/td\u003e\n\u003ctd\u003e750-1,000 Lux\u003c\/td\u003e\n\u003ctd\u003e75-100 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual Tasks of Low Contrast\u003c\/td\u003e\n\u003ctd\u003e1,000-2,000 Lux\u003c\/td\u003e\n\u003ctd\u003e100-200 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance of Visual Tasks of Low Contrast\u003c\/td\u003e\n\u003ctd\u003e2,000-5,000 Lux\u003c\/td\u003e\n\u003ctd\u003e200-500 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance of Visual Tasks Requiring Extreme Accuracy\u003c\/td\u003e\n\u003ctd\u003e5,000-10,000 Lux\u003c\/td\u003e\n\u003ctd\u003e500-1,000 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercast Day (Outdoor)\u003c\/td\u003e\n\u003ctd\u003e10,000-25,000 Lux\u003c\/td\u003e\n\u003ctd\u003e1,000-2,500 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Sunlight (Outdoor)\u003c\/td\u003e\n\u003ctd\u003e32,000-100,000 Lux\u003c\/td\u003e\n\u003ctd\u003e3,200-10,000 Ft-cd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperating Instructions Lutron LX-102 Digital Light Meter\u003c\/h3\u003e\n\u003col\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePower On\u003c\/strong\u003e - Turn on the meter using the power switch\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRange Selection\u003c\/strong\u003e - Choose the appropriate Lux or Foot-candle range according to the environment\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSensor Positioning\u003c\/strong\u003e - Place the sensor in the location where you want to measure illumination\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStabilization\u003c\/strong\u003e - Allow a brief moment for the reading to stabilize\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eReading\u003c\/strong\u003e - Observe the measurement on the LCD display\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Hold\u003c\/strong\u003e - If needed, press the HOLD button to freeze the current reading\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMultiple Measurements\u003c\/strong\u003e - For comprehensive assessment, take readings at multiple points in the area\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRecording\u003c\/strong\u003e - Document the readings manually or connect to external devices via analog output\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMaintenance Tips Lutron LX-102 Digital Light Meter\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSensor Care\u003c\/strong\u003e - Keep the photodiode sensor surface clean and free from dust or scratches\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBattery Management\u003c\/strong\u003e - Replace the 9V battery when the low battery indicator appears\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStorage\u003c\/strong\u003e - Store in a dry place away from extreme temperatures when not in use\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCalibration\u003c\/strong\u003e - For continued accuracy, perform occasional zero adjustment using the internal adjustment function\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCleaning\u003c\/strong\u003e - Wipe the meter body with a slightly damp cloth if necessary; avoid solvents\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSensor Protection\u003c\/strong\u003e - When not in use, protect the sensor from direct light exposure to prevent degradation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAbout Lutron Electronic Lutron LX-102 Digital Light Meter\u003c\/h3\u003e\nLutron Electronic is a leading manufacturer of professional test and measurement instruments, known worldwide for their quality, reliability, and innovation. With ISO-9001 certification, Lutron maintains strict quality control standards throughout their manufacturing processes. Their comprehensive product range includes light meters, environmental meters, sound level meters, anemometers, and various other testing equipment for industrial, commercial, and research applications.\n\u003ch3\u003eComparison with Other Light Meters Lutron LX-102 Digital Light Meter\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eLutron LX-102\u003c\/th\u003e\n\u003cth\u003eBasic Light Meters\u003c\/th\u003e\n\u003cth\u003ePremium Light Meters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0-50,000 Lux \/ 0-5,000 Ft-cd\u003c\/td\u003e\n\u003ctd\u003eTypically 0-20,000 Lux\u003c\/td\u003e\n\u003ctd\u003eSimilar or slightly higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(5% + 2 digits)\u003c\/td\u003e\n\u003ctd\u003e±10% or less\u003c\/td\u003e\n\u003ctd\u003e±3-4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eC.I.E. photopic compliant\u003c\/td\u003e\n\u003ctd\u003eBasic photodiode\u003c\/td\u003e\n\u003ctd\u003eSimilar compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Design\u003c\/td\u003e\n\u003ctd\u003eDetachable\u003c\/td\u003e\n\u003ctd\u003eOften fixed\u003c\/td\u003e\n\u003ctd\u003eUsually detachable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eRarely available\u003c\/td\u003e\n\u003ctd\u003eOften available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eISO-9001, CE, IEC1010\u003c\/td\u003e\n\u003ctd\u003eVaries, often minimal\u003c\/td\u003e\n\u003ctd\u003eSimilar certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Price Range\u003c\/td\u003e\n\u003ctd\u003eMid-range\u003c\/td\u003e\n\u003ctd\u003eLow-cost\u003c\/td\u003e\n\u003ctd\u003eHigh-end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat's in the Box Lutron LX-102 Digital Light Meter\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003eLutron LX-102 Digital Light Meter main unit\u003c\/li\u003e\n \t\u003cli\u003eDetachable light sensor probe\u003c\/li\u003e\n \t\u003cli\u003e9V battery (depending on region)\u003c\/li\u003e\n \t\u003cli\u003eInstruction manual\u003c\/li\u003e\n \t\u003cli\u003eProtective carrying case (in some regions)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose the Lutron LX-102?\u003c\/h3\u003e\n\u003ch4\u003eProfessional Quality \u0026amp; Reliability Lutron LX-102 Digital Light Meter\u003c\/h4\u003e\nWith ISO-9001, CE, and IEC1010 certifications, the LX-102 meets international quality and safety standards. The LSI-circuit design and professional sensor technology ensure consistent, reliable performance for critical light measurement applications.\n\u003ch4\u003eExcellent Value for Professional Features Lutron LX-102 Digital Light Meter\u003c\/h4\u003e\nThe LX-102 offers features typically found in more expensive models—including multiple ranges, separate sensor, data hold, and analog output—at a competitive price point. This makes it an excellent choice for professionals who need accurate light measurements without investing in laboratory-grade equipment.\n\u003ch4\u003eVersatile Application Range Lutron LX-102 Digital Light Meter\u003c\/h4\u003e\nWith its wide measurement range (0-50,000 Lux), dual unit display (Lux\/Foot-candle), and flexible sensor positioning, the LX-102 is suitable for virtually any lighting measurement scenario. From dim emergency lighting to bright outdoor conditions, this single instrument handles diverse measurement needs.\n\u003ch4\u003eUser-Friendly Operation Lutron LX-102 Digital Light Meter\u003c\/h4\u003e\nDesigned for straightforward operation with clear display readings and simple controls, the LX-102 requires minimal training. The data hold function, quick sampling time (0.4 second), and detachable sensor make it convenient to use even in challenging measurement environments.\n\u003ch3\u003eSummary Lutron LX-102 Digital Light Meter\u003c\/h3\u003e\nThe Lutron LX-102 Digital Light Meter is a professional-grade illuminance measurement tool that offers exceptional accuracy, versatility, and ease of use. With its ISO-9001 certification, C.I.E. photopic compliant sensor, and multiple measurement ranges, this meter delivers reliable light intensity readings for photography, workplace safety assessment, architectural design, and research applications.\n\nKey advantages include the detachable sensor for optimal positioning, data hold functionality for convenient recording, and analog output capability for continuous monitoring. The compact design and clear LCD display make it highly portable and easy to use in various environments.\n\nWhether you're a professional photographer setting up studio lighting, a safety inspector verifying workplace illumination standards, or a researcher monitoring environmental light conditions, the Lutron LX-102 provides the precision, features, and reliability needed for accurate light measurement at a competitive price point.","brand":"Lutron","offers":[{"title":"Default Title","offer_id":51460962517238,"sku":"LUT-LUX-102","price":7080.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Lutron_LX-102_Digital_Light_Meter__37620.1754460353.386.513_fd244790-2cc9-46e9-b431-280c21bf8496.jpg?v=1786598842"},{"product_id":"lutron-lx-1102-professional-light-meter","title":"Lutron LX-1102 Professional Light Meter","description":"\u003cdiv class=\"powr-chat\" id=\"1abb102c_1753877895\"\u003e\u003c\/div\u003e\n\u003ch2\u003eLutron LX-1102 Professional Light Meter\u003c\/h2\u003e\n\u003ch2\u003eLutron LX-1102 Professional Digital Light Meter\u003c\/h2\u003e\nThe Lutron LX-1102 is a high-precision digital light meter designed for professional illuminance measurement across various applications. This ISO-9001, CE, and IEC1010 certified instrument delivers exceptional accuracy with 5 measurement ranges spanning from 0.01 Lux to 400,000 Lux, making it suitable for everything from low-light environments to bright outdoor conditions.\n\u003ch3\u003eKey Features \u0026amp; Benefits Lutron LX-1102 Professional Light Meter\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range\u003c\/strong\u003e - 5 selectable ranges: 40.00\/400.0\/4,000\/40,000\/400,000 Lux for comprehensive light measurement\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh Resolution\u003c\/strong\u003e - Precise readings from 0.01 Lux to 100 Lux (0.01 Ft-cd to 10 Ft-cd)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProfessional Certification\u003c\/strong\u003e - ISO-9001, CE, and IEC1010 certified for guaranteed quality and safety\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAdvanced Sensor Technology\u003c\/strong\u003e - Exclusive photodiode with color correction filter matching C.I.E. photopic standard\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCosine Correction\u003c\/strong\u003e - Sensor meets cosine angular incidence standards for accurate readings at different angles\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSeparate Light Sensor\u003c\/strong\u003e - Detachable sensor allows for optimal positioning during measurement\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDual Unit Display\u003c\/strong\u003e - Switch between Lux and Foot-candle (Ft-cd) measurements\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLarge LCD Display\u003c\/strong\u003e - Clear 52 x 38 mm screen with 4 digits and bargraph indicator\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Hold Function\u003c\/strong\u003e - Freeze current readings for easy recording\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePeak Hold\u003c\/strong\u003e - Capture and hold maximum light intensity peaks\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMemory Function\u003c\/strong\u003e - Store maximum and minimum values with recall capability\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eZero Adjustment\u003c\/strong\u003e - External adjustment button for calibration (40.00 Lux range only)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAuto Power Off\u003c\/strong\u003e - Conserves battery life with optional manual power off\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRS-232 Output\u003c\/strong\u003e - Computer interface for data logging and analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWater-Resistant Panel\u003c\/strong\u003e - Front panel protection for durability in various environments\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRubber Function Keys\u003c\/strong\u003e - User-friendly, durable operation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLow Battery Indicator\u003c\/strong\u003e - Built-in warning system when replacement is needed\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompact Design\u003c\/strong\u003e - Lightweight (220g\/0.48 LB) and portable for field use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Lutron LX-1102 Professional Light Meter\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLutron LX-1102 Professional Light Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge LCD display, 52 x 38 mm, 4 digits with bargraph indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ranges: 40.00\/400.0\/4,000\/40,000\/400,000 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLux, Foot-candle (Ft-cd)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExclusive photodiode \u0026amp; color correction filter, spectrum meets C.I.E. photopic standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZero Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal adjustment by pushing button (40.00 Lux range only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePeak Hold, Data Hold, Memory (Max \u0026amp; Min) with Recall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver range: \"- - - -\", Under range: \"_ _ _ _\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto or manual power off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232 serial data output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 9V battery, 006P, MN1604 (PP3) or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. DC 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 g\/0.48 LB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain instrument: 200 x 68 x 30 mm (7.9 x 2.7 x 1.2 inch)\nSensor probe: 82 x 55 x 7 mm (3.2 x 2.2 x 0.3 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessories Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstruction Manual (1 PC), Light Sensor with protection cover (1 PC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 cable (UPCB-02), Application Software (SW-U801-WIN), Hard carrying case (CA-06), Soft carrying case (CA-05A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMeasurement Accuracy\u003c\/h3\u003e\n\u003ch4\u003eLux Measurement\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eIn-range Display\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40.00 Lux\u003c\/td\u003e\n\u003ctd\u003e0 - 40.00 Lux\u003c\/td\u003e\n\u003ctd\u003e0.01 Lux\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e±(3% rdg + 0.5% F.S.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400.0 Lux\u003c\/td\u003e\n\u003ctd\u003e36.0 - 400.0 Lux\u003c\/td\u003e\n\u003ctd\u003e0.1 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4,000 Lux\u003c\/td\u003e\n\u003ctd\u003e360 - 4,000 Lux\u003c\/td\u003e\n\u003ctd\u003e1 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40,000 Lux\u003c\/td\u003e\n\u003ctd\u003e3,600 - 40,000 Lux\u003c\/td\u003e\n\u003ctd\u003e10 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400,000 Lux\u003c\/td\u003e\n\u003ctd\u003e10,000 - 400,000 Lux\u003c\/td\u003e\n\u003ctd\u003e100 Lux\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100,000 Lux: ±(3% rdg + 0.5% F.S.)\n≥100,000 Lux: for reference only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFoot-candle (Fc) Measurement\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eIn-range Display\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.000 Fc\u003c\/td\u003e\n\u003ctd\u003e0 - 3.720 Fc\u003c\/td\u003e\n\u003ctd\u003e0.001 Fc\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e±(3% rdg + 0.5% F.S.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40.00 Fc\u003c\/td\u003e\n\u003ctd\u003e3.35 - 37.20 Fc\u003c\/td\u003e\n\u003ctd\u003e0.01 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400.0 Fc\u003c\/td\u003e\n\u003ctd\u003e33.5 - 372.0 Fc\u003c\/td\u003e\n\u003ctd\u003e0.1 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4,000 Fc\u003c\/td\u003e\n\u003ctd\u003e335 - 3,720 Fc\u003c\/td\u003e\n\u003ctd\u003e1 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40,000 Fc\u003c\/td\u003e\n\u003ctd\u003e930 - 37,200 Fc\u003c\/td\u003e\n\u003ctd\u003e10 Fc\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;9,300 Fc: ±(3% rdg + 0.5% F.S.)\n≥9,300 Fc: for reference only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cem\u003eNote: Accuracy tested by a standard parallel light tungsten lamp of 2856 K degree temperature.\u003c\/em\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003ch4\u003ePhotography \u0026amp; Videography Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProfessional Studio Setup\u003c\/strong\u003e - Precisely measure illumination levels for optimal exposure\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOn-Location Assessment\u003c\/strong\u003e - Evaluate ambient lighting conditions before shooting\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFilm \u0026amp; Video Production\u003c\/strong\u003e - Ensure consistent lighting across scenes\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProduct Photography\u003c\/strong\u003e - Maintain standardized lighting for product catalogs\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLight Continuity\u003c\/strong\u003e - Monitor lighting consistency during extended shoots\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIndustrial \u0026amp; Workplace Safety Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOSHA Compliance\u003c\/strong\u003e - Verify illumination meets workplace safety standards\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFactory Floor Assessment\u003c\/strong\u003e - Ensure adequate lighting for manufacturing processes\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOffice Space Evaluation\u003c\/strong\u003e - Optimize lighting for employee productivity and comfort\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEmergency Lighting Testing\u003c\/strong\u003e - Validate emergency illumination systems\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuality Control Areas\u003c\/strong\u003e - Confirm proper lighting for inspection processes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eArchitectural \u0026amp; Environmental Design Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBuilding Commissioning\u003c\/strong\u003e - Verify lighting installations meet design specifications\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnergy Efficiency Audits\u003c\/strong\u003e - Identify opportunities for lighting optimization\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eExhibition \u0026amp; Museum Lighting\u003c\/strong\u003e - Set appropriate illumination for displays and artifacts\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLandscape \u0026amp; Outdoor Lighting\u003c\/strong\u003e - Measure illumination for exterior architectural features\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRetail Environment Assessment\u003c\/strong\u003e - Optimize lighting for merchandise displays\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eResearch \u0026amp; Education Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eScientific Research\u003c\/strong\u003e - Monitor light conditions for experiments and studies\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAgricultural \u0026amp; Horticultural Studies\u003c\/strong\u003e - Measure light intensity for plant growth research\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEducational Facilities\u003c\/strong\u003e - Ensure proper illumination in classrooms and laboratories\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnvironmental Studies\u003c\/strong\u003e - Track natural and artificial light levels over time\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Logging \u0026amp; Analysis\u003c\/strong\u003e - Connect to computer systems for extended light studies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Features Explained\u003c\/h3\u003e\n\u003ch4\u003eProfessional Sensor Technology Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\nThe LX-1102 employs an exclusive photodiode with specialized color correction filter that precisely matches the C.I.E. photopic curve—the international standard that corresponds to human eye light response. This ensures the meter measures light intensity as perceived by the human eye rather than just physical radiation, providing more relevant readings for practical applications.\n\nThe sensor's cosine correction factor standardization further enhances accuracy by accounting for the angle at which light strikes the sensor surface. This means measurements remain consistent even when light comes from different directions, not just perpendicular to the sensor.\n\u003ch4\u003eFive-Range Measurement System Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\nWith its five selectable measurement ranges, the LX-1102 offers unprecedented flexibility across the entire spectrum of illumination levels:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e40.00 Lux Range\u003c\/strong\u003e - Ultra-high resolution (0.01 Lux) for measuring very low light levels in emergency lighting, night environments, or dark rooms\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e400.0 Lux Range\u003c\/strong\u003e - Suitable for normal indoor lighting assessment in offices, schools, and homes\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e4,000 Lux Range\u003c\/strong\u003e - Ideal for brighter indoor environments, workplace safety verification, and commercial spaces\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e40,000 Lux Range\u003c\/strong\u003e - Perfect for measuring bright indoor lighting, covered outdoor areas, and partially shaded daylight\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e400,000 Lux Range\u003c\/strong\u003e - Capable of measuring full daylight, direct sunlight, and extremely bright artificial lighting\u003c\/li\u003e\n\u003c\/ul\u003e\nThis extensive range capability eliminates the need for multiple meters or accessories, making the LX-1102 suitable for virtually any lighting measurement application.\n\u003ch4\u003eAdvanced Data Functions Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\nThe LX-1102 offers several sophisticated data handling features that enhance its utility for professional applications:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePeak Hold\u003c\/strong\u003e - Captures and displays the maximum light intensity detected, particularly useful for measuring flash or pulsed lighting\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Hold\u003c\/strong\u003e - Freezes the current reading on the display for easy recording, especially helpful in hard-to-reach measurement locations\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMemory Function\u003c\/strong\u003e - Stores maximum and minimum values during a measurement session, with recall capability to review the range of illumination detected\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRS-232 Data Output\u003c\/strong\u003e - Connect to computers for real-time data logging, extended monitoring, or integration with other measurement systems\u003c\/li\u003e\n\u003c\/ul\u003e\nThese features make the LX-1102 particularly valuable for detailed light studies, quality control applications, and situations requiring documentation of lighting conditions over time.\n\u003ch3\u003eRecommended Light Levels Lutron LX-1102 Professional Light Meter\u003c\/h3\u003e\nThe Lutron LX-1102 helps verify that illumination meets recommended standards for different environments:\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\/Activity\u003c\/th\u003e\n\u003cth\u003eRecommended Illuminance (Lux)\u003c\/th\u003e\n\u003cth\u003eFoot-candle Equivalent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Staircases, Storage Areas\u003c\/td\u003e\n\u003ctd\u003e50-100 Lux\u003c\/td\u003e\n\u003ctd\u003e5-10 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorridors, Hallways\u003c\/td\u003e\n\u003ctd\u003e100-150 Lux\u003c\/td\u003e\n\u003ctd\u003e10-15 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarehouses, Homes, Theaters\u003c\/td\u003e\n\u003ctd\u003e150-250 Lux\u003c\/td\u003e\n\u003ctd\u003e15-25 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Office Work, Classrooms\u003c\/td\u003e\n\u003ctd\u003e250-500 Lux\u003c\/td\u003e\n\u003ctd\u003e25-50 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetailed Office Work, Libraries\u003c\/td\u003e\n\u003ctd\u003e500-750 Lux\u003c\/td\u003e\n\u003ctd\u003e50-75 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratories, Technical Drawing\u003c\/td\u003e\n\u003ctd\u003e750-1,000 Lux\u003c\/td\u003e\n\u003ctd\u003e75-100 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecision Assembly, Detailed Inspection\u003c\/td\u003e\n\u003ctd\u003e1,000-2,000 Lux\u003c\/td\u003e\n\u003ctd\u003e100-200 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Assembly, Fine Engraving\u003c\/td\u003e\n\u003ctd\u003e2,000-5,000 Lux\u003c\/td\u003e\n\u003ctd\u003e200-500 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecision Mechanisms, Microsurgery\u003c\/td\u003e\n\u003ctd\u003e5,000-10,000 Lux\u003c\/td\u003e\n\u003ctd\u003e500-1,000 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercast Day (Outdoor)\u003c\/td\u003e\n\u003ctd\u003e10,000-25,000 Lux\u003c\/td\u003e\n\u003ctd\u003e1,000-2,500 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Daylight (Outdoor, No Direct Sun)\u003c\/td\u003e\n\u003ctd\u003e25,000-50,000 Lux\u003c\/td\u003e\n\u003ctd\u003e2,500-5,000 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Sunlight\u003c\/td\u003e\n\u003ctd\u003e50,000-100,000+ Lux\u003c\/td\u003e\n\u003ctd\u003e5,000-10,000+ Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperating Instructions Lutron LX-1102 Professional Light Meter\u003c\/h3\u003e\n\u003col\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePower On\u003c\/strong\u003e - Turn on the meter and allow it to stabilize\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRange Selection\u003c\/strong\u003e - Select the appropriate measurement range based on expected illumination level\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUnit Selection\u003c\/strong\u003e - Choose between Lux or Foot-candle (Ft-cd) display\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eZero Adjustment\u003c\/strong\u003e - If using the 40.00 Lux range, perform zero adjustment in a dark environment using the adjustment button\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSensor Positioning\u003c\/strong\u003e - Place the light sensor in the location where you want to measure illumination\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eReading\u003c\/strong\u003e - Observe the measurement on the LCD display and the bargraph indicator\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Functions\u003c\/strong\u003e - Use Data Hold to freeze readings, Peak Hold to capture maximum values, or Memory function to store min\/max readings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Output\u003c\/strong\u003e - If required, connect to a computer via optional RS-232 cable for data logging\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePower Off\u003c\/strong\u003e - Turn off manually or allow auto power off to conserve battery\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMaintenance Tips Lutron LX-1102 Professional Light Meter\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSensor Care\u003c\/strong\u003e - Keep the photodiode sensor clean and protected with the included cover when not in use\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBattery Management\u003c\/strong\u003e - Replace the 9V battery when the low battery indicator appears\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCalibration\u003c\/strong\u003e - Perform occasional zero adjustment using the adjustment button to maintain accuracy\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStorage\u003c\/strong\u003e - Store in a dry, dust-free environment away from direct sunlight\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCleaning\u003c\/strong\u003e - Use a soft, dry cloth to clean the meter body and display; avoid solvents\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWater Resistance\u003c\/strong\u003e - While the front panel is water-resistant, avoid exposing the entire instrument to moisture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncluded and Optional Accessories\u003c\/h3\u003e\n\u003ch4\u003eStandard Included Accessories Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLight Sensor with Protection Cover\u003c\/strong\u003e - The high-quality sensor module with protective cap to prevent damage when not in use\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eInstruction Manual\u003c\/strong\u003e - Comprehensive guide to operation, specifications, and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional Accessories Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRS232 Cable (UPCB-02)\u003c\/strong\u003e - Connect the meter to a computer for data logging and analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eApplication Software (SW-U801-WIN)\u003c\/strong\u003e - Windows-compatible software for data capture and analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHard Carrying Case (CA-06)\u003c\/strong\u003e - Durable protective case for secure transportation and storage\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSoft Carrying Case (CA-05A)\u003c\/strong\u003e - Lightweight pouch for convenient carrying and protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAbout Lutron Electronic Lutron LX-1102 Professional Light Meter\u003c\/h3\u003e\nLutron Electronic is a leading manufacturer of professional test and measurement instruments with ISO-9001 certification. Their comprehensive product range includes light meters, sound level meters, environmental meters, and various other precision measuring devices for industrial, commercial, educational, and research applications. With a focus on quality, innovation, and usability, Lutron instruments are trusted by professionals worldwide for their accuracy, reliability, and value.\n\u003ch3\u003eWhy Choose the Lutron LX-1102 Professional Light Meter?\u003c\/h3\u003e\n\u003ch4\u003eSuperior Measurement Range \u0026amp; Accuracy Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\nWith five selectable ranges spanning from ultra-low light (0.01 Lux resolution) to extremely bright conditions (up to 400,000 Lux), the LX-1102 offers unmatched versatility. The ±3% accuracy is exceptional for its class, ensuring reliable measurements for critical applications. The high-quality sensor with C.I.E. photopic compliance and cosine correction delivers readings that accurately reflect human-perceived illumination.\n\u003ch4\u003eAdvanced Professional Features Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\nThe comprehensive data functions—including Peak Hold, Data Hold, and Memory with Min\/Max recall—provide capabilities typically found only in more expensive instruments. The RS-232 computer interface extends functionality for data logging and analysis, making this meter suitable for research and documentation requirements.\n\u003ch4\u003eQuality Construction \u0026amp; Usability Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\nThe water-resistant front panel, rubber function keys, and durable construction ensure reliability in various environments. The large LCD display with bargraph indicator provides clear visibility of readings, while the separate light sensor design allows for optimal measurement positioning without awkward handling of the main unit.\n\u003ch4\u003eInternational Certification Lutron LX-1102 Professional Light Meter\u003c\/h4\u003e\nWith ISO-9001, CE, and IEC1010 certifications, the LX-1102 meets international quality and safety standards. These certifications provide assurance that the instrument has been manufactured under strict quality control protocols and complies with relevant safety requirements for electrical measuring equipment.\n\u003ch3\u003eSummary Lutron LX-1102 Professional Light Meter\u003c\/h3\u003e\nThe Lutron LX-1102 Professional Digital Light Meter represents an exceptional combination of measurement range, accuracy, and advanced functionality in a compact, user-friendly package. With its five measurement ranges spanning from 0.01 Lux to 400,000 Lux, high-quality sensor technology, and comprehensive data handling capabilities, this meter is suitable for virtually any illumination measurement application.\n\nWhether you're a professional photographer setting up studio lighting, a safety inspector verifying workplace illumination standards, an architect validating lighting design, or a researcher conducting environmental light studies, the LX-1102 provides the precision, features, and reliability needed for accurate light intensity assessment. The optional RS-232 interface and software further extend its capabilities for data logging and analysis applications.\n\nManufactured by Lutron Electronic, a recognized leader in test and measurement instruments, and certified to ISO-9001, CE, and IEC1010 standards, the LX-1102 offers professional quality at a competitive price point. Its robust construction, intuitive operation, and comprehensive feature set make it an excellent investment for anyone requiring dependable illuminance measurements across a wide range of applications.","brand":"Lutron","offers":[{"title":"Default Title","offer_id":51460963139830,"sku":"LUT-LUX-1102","price":8850.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Lutron_LX-1102_Professional_Light_Meter__37444.1754460967.386.513_54118f7b-3f3a-4f42-ae1d-47e8e70067d9.jpg?v=1786598856"},{"product_id":"lutron-lx-1108-4-light-type-digital-light-meter","title":"Lutron LX-1108 4-Light Type Digital Light Meter","description":"\u003cdiv class=\"powr-chat\" id=\"1abb102c_1753877895\"\u003e\u003c\/div\u003e\n\u003ch2\u003eLutron LX-1108 4-Light Type Digital Light Meter\u003c\/h2\u003e\n\u003ch2\u003eLutron LX-1108 Professional Digital Light Meter with 4-Light Type Selection\u003c\/h2\u003e\nThe Lutron LX-1108 is an advanced digital light meter designed for professional light measurement across various lighting technologies. This ISO-9001, CE, and IEC1010 certified instrument delivers exceptional accuracy with 5 measurement ranges spanning from 0.01 Lux to 400,000 Lux, making it the ideal choice for lighting professionals, photographers, safety inspectors, and researchers who require precise illuminance readings for different light sources.\n\u003ch3\u003eKey Features \u0026amp; Benefits Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e4-Light Type Selection\u003c\/strong\u003e - Specialized calibration for Tungsten, Fluorescent, Sodium, and Mercury light sources\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWide Measurement Range\u003c\/strong\u003e - 5 selectable ranges: 40.00\/400.0\/4,000\/40,000\/400,000 Lux for comprehensive light measurement\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh Resolution\u003c\/strong\u003e - Precise readings from 0.01 Lux to 100 Lux (0.01 Ft-cd to 10 Ft-cd)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProfessional Certification\u003c\/strong\u003e - ISO-9001, CE, and IEC1010 certified for guaranteed quality and safety\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAdvanced Sensor Technology\u003c\/strong\u003e - Exclusive photodiode with color correction filter matching C.I.E. photopic standard\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCosine Correction\u003c\/strong\u003e - Sensor meets cosine angular incidence standards for accurate readings at different angles\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSeparate Light Sensor\u003c\/strong\u003e - Detachable sensor allows for optimal positioning during measurement\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDual Unit Display\u003c\/strong\u003e - Switch between Lux and Foot-candle (Ft-cd) measurements\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLarge LCD Display\u003c\/strong\u003e - Clear 52 x 38 mm screen with 4 digits and bargraph indicator\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Hold Function\u003c\/strong\u003e - Freeze current readings for easy recording\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePeak Hold\u003c\/strong\u003e - Capture and hold maximum light intensity peaks\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMemory Function\u003c\/strong\u003e - Store maximum and minimum values with recall capability\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eZero Adjustment\u003c\/strong\u003e - External adjustment button for calibration (40.00 Lux range only)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAuto Power Off\u003c\/strong\u003e - Conserves battery life with optional manual power off\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRS-232 Output\u003c\/strong\u003e - Computer interface for data logging and analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWater-Resistant Panel\u003c\/strong\u003e - Front panel protection for durability in various environments\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRubber Function Keys\u003c\/strong\u003e - User-friendly, durable operation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLow Battery Indicator\u003c\/strong\u003e - Built-in warning system when replacement is needed\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompact Design\u003c\/strong\u003e - Lightweight (220g\/0.48 LB) and portable for field use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLutron LX-1108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge LCD display, 52 x 38 mm, 4 digits with bargraph indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ranges: 40.00\/400.0\/4,000\/40,000\/400,000 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLux, Foot-candle (Ft-cd)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Type Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTungsten, Fluorescent, Sodium, Mercury lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExclusive photodiode \u0026amp; color correction filter, spectrum meets C.I.E. photopic standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZero Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal adjustment by pushing button (40.00 Lux range only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePeak Hold, Data Hold, Memory (Max \u0026amp; Min) with Recall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver range: \"- - - -\", Under range: \"_ _ _ _\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto or manual power off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232 serial data output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 9V battery, 006P, MN1604 (PP3) or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. DC 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 g\/0.48 LB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain instrument: 200 x 68 x 30 mm (7.9 x 2.7 x 1.2 inch)\nSensor probe: 82 x 55 x 7 mm (3.2 x 2.2 x 0.3 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessories Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstruction Manual (1 PC), Light Sensor with protection cover (1 PC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 cable (UPCB-02), USB cable (USB-01), Application Software (SW-U801-WIN), Hard carrying case (CA-06), Soft carrying case (CA-05A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMeasurement Accuracy\u003c\/h3\u003e\n\u003ch4\u003eLux Measurement Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eIn-range Display\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40.00 Lux\u003c\/td\u003e\n\u003ctd\u003e0 - 40.00 Lux\u003c\/td\u003e\n\u003ctd\u003e0.01 Lux\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e±(3% rdg + 0.5% F.S.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400.0 Lux\u003c\/td\u003e\n\u003ctd\u003e36.0 - 400.0 Lux\u003c\/td\u003e\n\u003ctd\u003e0.1 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4,000 Lux\u003c\/td\u003e\n\u003ctd\u003e360 - 4,000 Lux\u003c\/td\u003e\n\u003ctd\u003e1 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40,000 Lux\u003c\/td\u003e\n\u003ctd\u003e3,600 - 40,000 Lux\u003c\/td\u003e\n\u003ctd\u003e10 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400,000 Lux\u003c\/td\u003e\n\u003ctd\u003e10,000 - 400,000 Lux\u003c\/td\u003e\n\u003ctd\u003e100 Lux\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100,000 Lux: ±(3% rdg + 0.5% F.S.)\n≥100,000 Lux: for reference only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFoot-candle (Fc) Measurement Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eIn-range Display\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.000 Fc\u003c\/td\u003e\n\u003ctd\u003e0 - 3.720 Fc\u003c\/td\u003e\n\u003ctd\u003e0.001 Fc\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e±(3% rdg + 0.5% F.S.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40.00 Fc\u003c\/td\u003e\n\u003ctd\u003e3.35 - 37.20 Fc\u003c\/td\u003e\n\u003ctd\u003e0.01 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400.0 Fc\u003c\/td\u003e\n\u003ctd\u003e33.5 - 372.0 Fc\u003c\/td\u003e\n\u003ctd\u003e0.1 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4,000 Fc\u003c\/td\u003e\n\u003ctd\u003e335 - 3,720 Fc\u003c\/td\u003e\n\u003ctd\u003e1 Fc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40,000 Fc\u003c\/td\u003e\n\u003ctd\u003e930 - 37,200 Fc\u003c\/td\u003e\n\u003ctd\u003e10 Fc\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;9,300 Fc: ±(3% rdg + 0.5% F.S.)\n≥9,300 Fc: for reference only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cem\u003eNote: Accuracy tested by a standard parallel light tungsten lamp of 2856 K degree temperature.\u003c\/em\u003e\n\u003ch3\u003e4-Light Type Selection: A Unique Advantage\u003c\/h3\u003e\nThe LX-1108's standout feature is its specialized 4-light type selection capability, which allows for accurate measurements across different lighting technologies:\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLight Type\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eCommon Applications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTungsten\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTraditional incandescent lighting with warmer color temperature\u003c\/td\u003e\n\u003ctd\u003eResidential lighting, photography studios, theatrical lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFluorescent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGas-discharge lighting with different spectral characteristics\u003c\/td\u003e\n\u003ctd\u003eOffice spaces, commercial buildings, schools, retail environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSodium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh\/low pressure sodium vapor lighting with distinctive yellow spectrum\u003c\/td\u003e\n\u003ctd\u003eStreet lighting, security lighting, industrial facilities, warehouses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMercury\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMercury vapor lighting with blue-green spectrum\u003c\/td\u003e\n\u003ctd\u003eIndustrial spaces, gymnasiums, parking lots, outdoor area lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\nThis multi-type capability ensures accurate readings regardless of light source, as different lighting technologies produce light with varying spectral distributions that can affect measurement accuracy with standard light meters. The LX-1108 compensates for these variations, providing true readings for each specific light type.\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003ch4\u003eProfessional Photography \u0026amp; Videography Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMixed Lighting Environments\u003c\/strong\u003e - Accurately measure different light sources in the same setting\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStudio Setup\u003c\/strong\u003e - Precisely calibrate tungsten lighting for portrait and product photography\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLocation Shoots\u003c\/strong\u003e - Evaluate ambient fluorescent, sodium, or mercury lighting before setting up\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCinematography\u003c\/strong\u003e - Ensure consistent lighting across scenes with different light sources\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLight Continuity\u003c\/strong\u003e - Monitor lighting consistency during extended shoots with changing conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eArchitectural \u0026amp; Environmental Lighting Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBuilding Commissioning\u003c\/strong\u003e - Verify various lighting installations meet design specifications\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLighting Retrofits\u003c\/strong\u003e - Compare illumination levels before and after upgrading lighting systems\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMixed-Use Spaces\u003c\/strong\u003e - Measure different lighting technologies throughout diverse environments\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOutdoor Lighting Assessment\u003c\/strong\u003e - Accurately evaluate sodium and mercury vapor street lighting\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnergy Efficiency Audits\u003c\/strong\u003e - Document illumination levels across different lighting technologies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIndustrial \u0026amp; Workplace Safety Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOSHA Compliance\u003c\/strong\u003e - Verify illumination meets workplace safety standards in varied lighting\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eManufacturing Facilities\u003c\/strong\u003e - Ensure adequate lighting across production areas with different light types\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuality Control\u003c\/strong\u003e - Maintain optimal lighting for inspection processes under specific light sources\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEmergency Lighting Testing\u003c\/strong\u003e - Validate emergency illumination systems\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMixed Industrial Environments\u003c\/strong\u003e - Measure both indoor fluorescent and outdoor sodium\/mercury lighting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eResearch \u0026amp; Education Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLighting Technology Studies\u003c\/strong\u003e - Compare illumination efficiency across different light sources\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHorticultural Research\u003c\/strong\u003e - Measure light intensity for plant growth under various light types\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnvironmental Impact Studies\u003c\/strong\u003e - Document lighting levels from different technologies\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEducational Demonstrations\u003c\/strong\u003e - Teach principles of illumination with various light sources\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLight Pollution Research\u003c\/strong\u003e - Measure intensity of different outdoor lighting technologies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Features Explained\u003c\/h3\u003e\n\u003ch4\u003eProfessional Sensor Technology Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\nThe LX-1108 employs an exclusive photodiode with specialized color correction filter that precisely matches the C.I.E. photopic curve—the international standard that corresponds to human eye light response. This ensures the meter measures light intensity as perceived by the human eye rather than just physical radiation, providing more relevant readings for practical applications.\n\nThe sensor's cosine correction factor standardization further enhances accuracy by accounting for the angle at which light strikes the sensor surface. This means measurements remain consistent even when light comes from different directions, not just perpendicular to the sensor.\n\u003ch4\u003eFive-Range Measurement System Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\nWith its five selectable measurement ranges, the LX-1108 offers exceptional flexibility across the entire spectrum of illumination levels:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e40.00 Lux Range\u003c\/strong\u003e - Ultra-high resolution (0.01 Lux) for measuring very low light levels in emergency lighting, night environments, or dark rooms\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e400.0 Lux Range\u003c\/strong\u003e - Suitable for normal indoor lighting assessment in offices, schools, and homes\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e4,000 Lux Range\u003c\/strong\u003e - Ideal for brighter indoor environments, workplace safety verification, and commercial spaces\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e40,000 Lux Range\u003c\/strong\u003e - Perfect for measuring bright indoor lighting, covered outdoor areas, and partially shaded daylight\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e400,000 Lux Range\u003c\/strong\u003e - Capable of measuring full daylight, direct sunlight, and extremely bright artificial lighting\u003c\/li\u003e\n\u003c\/ul\u003e\nThis extensive range capability eliminates the need for multiple meters or accessories, making the LX-1108 suitable for virtually any lighting measurement application across different lighting technologies.\n\u003ch4\u003eAdvanced Data Functions Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\nThe LX-1108 offers several sophisticated data handling features that enhance its utility for professional applications:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePeak Hold\u003c\/strong\u003e - Captures and displays the maximum light intensity detected, particularly useful for measuring flash or pulsed lighting\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Hold\u003c\/strong\u003e - Freezes the current reading on the display for easy recording, especially helpful in hard-to-reach measurement locations\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMemory Function\u003c\/strong\u003e - Stores maximum and minimum values during a measurement session, with recall capability to review the range of illumination detected\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRS-232 Data Output\u003c\/strong\u003e - Connect to computers for real-time data logging, extended monitoring, or integration with other measurement systems\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOptional USB Connectivity\u003c\/strong\u003e - Available with the optional USB-01 cable for modern computer connections\u003c\/li\u003e\n\u003c\/ul\u003e\nThese features make the LX-1108 particularly valuable for detailed light studies comparing different lighting technologies, quality control applications, and situations requiring documentation of lighting conditions over time.\n\u003ch3\u003eRecommended Light Levels Across Different Light Sources\u003c\/h3\u003e\nThe Lutron LX-1108's 4-light type selection capability is especially valuable when verifying that different lighting technologies meet recommended standards:\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003cth\u003eRecommended Illuminance\u003c\/th\u003e\n\u003cth\u003eCommon Light Source\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarehouses, Corridors\u003c\/td\u003e\n\u003ctd\u003e100-200 Lux\u003c\/td\u003e\n\u003ctd\u003eSodium or Mercury\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Office Areas\u003c\/td\u003e\n\u003ctd\u003e300-500 Lux\u003c\/td\u003e\n\u003ctd\u003eFluorescent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetailed Office Work\u003c\/td\u003e\n\u003ctd\u003e500-750 Lux\u003c\/td\u003e\n\u003ctd\u003eFluorescent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotography Studios\u003c\/td\u003e\n\u003ctd\u003e750-1,500 Lux\u003c\/td\u003e\n\u003ctd\u003eTungsten or Fluorescent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecision Assembly\u003c\/td\u003e\n\u003ctd\u003e1,000-2,000 Lux\u003c\/td\u003e\n\u003ctd\u003eFluorescent or Tungsten\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetailed Inspection\u003c\/td\u003e\n\u003ctd\u003e2,000-5,000 Lux\u003c\/td\u003e\n\u003ctd\u003eFluorescent or Tungsten\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Parking\u003c\/td\u003e\n\u003ctd\u003e20-50 Lux\u003c\/td\u003e\n\u003ctd\u003eSodium or Mercury\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStreet Lighting\u003c\/td\u003e\n\u003ctd\u003e5-30 Lux\u003c\/td\u003e\n\u003ctd\u003eSodium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetail Display Areas\u003c\/td\u003e\n\u003ctd\u003e750-1,500 Lux\u003c\/td\u003e\n\u003ctd\u003eMixed (Tungsten \u0026amp; Fluorescent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSports Facilities\u003c\/td\u003e\n\u003ctd\u003e300-750 Lux\u003c\/td\u003e\n\u003ctd\u003eMercury or Fluorescent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperating Instructions Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h3\u003e\n\u003col\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePower On\u003c\/strong\u003e - Turn on the meter and allow it to stabilize\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLight Type Selection\u003c\/strong\u003e - Choose the appropriate light source type (Tungsten, Fluorescent, Sodium, or Mercury)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRange Selection\u003c\/strong\u003e - Select the appropriate measurement range based on expected illumination level\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUnit Selection\u003c\/strong\u003e - Choose between Lux or Foot-candle (Ft-cd) display\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eZero Adjustment\u003c\/strong\u003e - If using the 40.00 Lux range, perform zero adjustment in a dark environment using the adjustment button\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSensor Positioning\u003c\/strong\u003e - Place the light sensor in the location where you want to measure illumination\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eReading\u003c\/strong\u003e - Observe the measurement on the LCD display and the bargraph indicator\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Functions\u003c\/strong\u003e - Use Data Hold to freeze readings, Peak Hold to capture maximum values, or Memory function to store min\/max readings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Output\u003c\/strong\u003e - If required, connect to a computer via optional RS-232 or USB cable for data logging\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePower Off\u003c\/strong\u003e - Turn off manually or allow auto power off to conserve battery\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMaintenance Tips Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSensor Care\u003c\/strong\u003e - Keep the photodiode sensor clean and protected with the included cover when not in use\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBattery Management\u003c\/strong\u003e - Replace the 9V battery when the low battery indicator appears\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCalibration\u003c\/strong\u003e - Perform occasional zero adjustment using the adjustment button to maintain accuracy\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStorage\u003c\/strong\u003e - Store in a dry, dust-free environment away from direct sunlight\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCleaning\u003c\/strong\u003e - Use a soft, dry cloth to clean the meter body and display; avoid solvents\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWater Resistance\u003c\/strong\u003e - While the front panel is water-resistant, avoid exposing the entire instrument to moisture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncluded and Optional Accessories\u003c\/h3\u003e\n\u003ch4\u003eStandard Included Accessories Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLight Sensor with Protection Cover\u003c\/strong\u003e - The high-quality sensor module with protective cap to prevent damage when not in use\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eInstruction Manual\u003c\/strong\u003e - Comprehensive guide to operation, specifications, and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional Accessories Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRS232 Cable (UPCB-02)\u003c\/strong\u003e - Connect the meter to a computer for data logging and analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUSB Cable (USB-01)\u003c\/strong\u003e - Modern computer connection option for data transfer\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eApplication Software (SW-U801-WIN)\u003c\/strong\u003e - Windows-compatible software for data capture and analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHard Carrying Case (CA-06)\u003c\/strong\u003e - Durable protective case for secure transportation and storage\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSoft Carrying Case (CA-05A)\u003c\/strong\u003e - Lightweight pouch for convenient carrying and protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAbout Lutron Electronic Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h3\u003e\nLutron Electronic is a leading manufacturer of professional test and measurement instruments with ISO-9001 certification. Their comprehensive product range includes light meters, sound level meters, environmental meters, and various other precision measuring devices for industrial, commercial, educational, and research applications. With a focus on quality, innovation, and usability, Lutron instruments are trusted by professionals worldwide for their accuracy, reliability, and value.\n\u003ch3\u003eComparison with Standard Light Meters Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eLutron LX-1108\u003c\/th\u003e\n\u003cth\u003eStandard Light Meters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Type Selection\u003c\/td\u003e\n\u003ctd\u003e4 types (Tungsten, Fluorescent, Sodium, Mercury)\u003c\/td\u003e\n\u003ctd\u003eTypically single calibration (usually Tungsten)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0.01 to 400,000 Lux (5 ranges)\u003c\/td\u003e\n\u003ctd\u003eTypically narrower range with fewer selection options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eAs fine as 0.01 Lux\u003c\/td\u003e\n\u003ctd\u003eOften limited to 1 Lux or 0.1 Lux minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% rdg + 0.5% F.S.)\u003c\/td\u003e\n\u003ctd\u003eTypically ±5% or less accurate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Functions\u003c\/td\u003e\n\u003ctd\u003ePeak Hold, Data Hold, Min\/Max Memory\u003c\/td\u003e\n\u003ctd\u003eOften limited to basic Data Hold only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputer Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232 and optional USB\u003c\/td\u003e\n\u003ctd\u003eRarely available in mid-range meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLarge LCD with bargraph\u003c\/td\u003e\n\u003ctd\u003eBasic numeric display only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Design\u003c\/td\u003e\n\u003ctd\u003eSeparate for optimal positioning\u003c\/td\u003e\n\u003ctd\u003eOften integrated into meter body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhy Choose the Lutron LX-1108?\u003c\/h3\u003e\n\u003ch4\u003eUnmatched Versatility Across Light Sources Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\nThe LX-1108's unique 4-light type selection capability sets it apart from standard light meters. By providing calibrated measurements for Tungsten, Fluorescent, Sodium, and Mercury lighting, this meter delivers accurate readings regardless of the light source—a critical feature in environments with mixed lighting technologies or for professionals who work across different settings.\n\u003ch4\u003eSuperior Measurement Range \u0026amp; Accuracy Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\nWith five selectable ranges spanning from ultra-low light (0.01 Lux resolution) to extremely bright conditions (up to 400,000 Lux), the LX-1108 offers exceptional versatility. The ±3% accuracy is superior for its class, ensuring reliable measurements for critical applications across all selected light types.\n\u003ch4\u003eAdvanced Professional Features Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\nThe comprehensive data functions—including Peak Hold, Data Hold, and Memory with Min\/Max recall—provide capabilities typically found only in more expensive instruments. The RS-232 computer interface with optional USB connectivity extends functionality for data logging and analysis, making this meter suitable for research and documentation requirements.\n\u003ch4\u003eQuality Construction \u0026amp; International Certification Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h4\u003e\nWith ISO-9001, CE, and IEC1010 certifications, the LX-1108 meets international quality and safety standards. The water-resistant front panel, rubber function keys, and durable construction ensure reliability in various environments, while the separate light sensor design allows for optimal measurement positioning.\n\u003ch3\u003eSummary Lutron LX-1108 4-Light Type Digital Light Meter\u003c\/h3\u003e\nThe Lutron LX-1108 Professional Digital Light Meter with 4-Light Type Selection represents the pinnacle of versatility and accuracy in illuminance measurement. Its unique ability to calibrate readings for Tungsten, Fluorescent, Sodium, and Mercury light sources ensures precise measurements across various lighting technologies, making it the ideal instrument for professionals who work with multiple light types. Lutron LX-1108 4-Light Type Digital Light Meter\n\nWith five measurement ranges spanning from 0.01 Lux to 400,000 Lux, high-quality sensor technology, and comprehensive data handling capabilities, the LX-1108 is suitable for virtually any illumination measurement application. The separate sensor design, large LCD display with bargraph, and user-friendly interface make it easy to use in various environments.\n\nWhether you're a lighting designer evaluating mixed lighting installations, a photographer working across different light sources, a safety inspector verifying workplace illumination standards in varied facilities, or a researcher studying different lighting technologies, the Lutron LX-1108 provides the specialized capabilities, precision, and reliability needed for accurate light intensity assessment across all common lighting types. Lutron LX-1108 4-Light Type Digital Light Meter\n\nManufactured by Lutron Electronic, a recognized leader in test and measurement instruments, and certified to ISO-9001, CE, and IEC1010 standards, the LX-1108 offers professional-grade features at a competitive price point, making it an excellent investment for any professional requiring reliable illuminance measurements across different lighting technologies.","brand":"Lutron","offers":[{"title":"Default Title","offer_id":51460963434742,"sku":"LUT-LUX-1108","price":14160.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Lutron_LX-1108_4-Light_Type_Digital_Light_Meter__92122.1754461223.386.513_12ccae48-ce90-460a-8af9-d10162e53cef.jpg?v=1786598863"},{"product_id":"workzone-lx-101-digital-lux-meter","title":"WORKZONE LX-101 Digital Lux Meter","description":"\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"281\"\u003e\u003cspan style=\"font-size: 14pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"281\" class=\"ng-star-inserted\"\u003eProduct Description: WORKZONE Digital Lux Meter (Model LX-101):\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"343\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"351\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"351\" class=\"ng-star-inserted\"\u003eThe WORKZONE LX-101 Digital Lux Meter is a professional-grade instrument designed for accurate and reliable measurement of illuminance\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"485\" class=\"ng-star-inserted\"\u003e. This device is suitable for a wide variety of applications, including auditing light levels in living quarters, offices, workshops, and industrial environments, ensuring optimal lighting conditions\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"684\" class=\"ng-star-inserted\"\u003e. Its design incorporates advanced technology to deliver precise and easy-to-read measurements\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"778\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"351\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"779\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"779\" class=\"ng-star-inserted\"\u003eKey Features and Benefits:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"779\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"804\"\u003e\n\u003cstrong class=\"ng-star-inserted\" data-start-index=\"804\"\u003ePrecision and Accuracy\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"826\" class=\"ng-star-inserted\"\u003e \u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"827\" class=\"ng-star-inserted\"\u003eThe LX-101 offers precise and easy readout across a wide range of measurement capabilities\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"917\" class=\"ng-star-inserted\"\u003e. It employs an \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"933\"\u003eexclusive photo diode and color correction filter\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"982\" class=\"ng-star-inserted\"\u003e, ensuring the spectrum meets C.I.E. photopic standards, resulting in high accuracy in measuring\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1078\" class=\"ng-star-inserted\"\u003e. The measurement accuracy is tested by a standard parallel light tungsten lamp of 2856 K temperature\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1179\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"804\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1180\"\u003e\n\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1180\"\u003eDurable and User-Friendly Design\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1212\" class=\"ng-star-inserted\"\u003e \u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1213\" class=\"ng-star-inserted\"\u003eThis digital lux meter uses \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1241\"\u003eLSI-circuit technology\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1263\" class=\"ng-star-inserted\"\u003e which provides exceptional durability and high reliability\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1322\" class=\"ng-star-inserted\"\u003e. The unit is compact, light-weight, and designed for excellent operation, making it pocket size and easy to carry out\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1440\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1180\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1441\"\u003e\n\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1441\"\u003eAdvanced Sensor Technology\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1467\" class=\"ng-star-inserted\"\u003e \u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1468\" class=\"ng-star-inserted\"\u003eA key feature is the \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1489\"\u003eseparate light sensor\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1510\" class=\"ng-star-inserted\"\u003e, which allows the user to position the sensor optimally for accurate light measurement, ensuring proper light readings even in hard-to-reach areas\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1657\" class=\"ng-star-inserted\"\u003e. The separate sensor is connected to the main instrument via a coiled cable\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1733\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1441\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1734\"\u003e\n\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1734\"\u003eClear Digital Readout\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1755\" class=\"ng-star-inserted\"\u003e \u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1756\" class=\"ng-star-inserted\"\u003eThe instrument is equipped with an LCD display that provides \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1817\"\u003elow power consumption\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1838\" class=\"ng-star-inserted\"\u003e and ensures a clear readout, even when operating in high ambient light environments\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1922\" class=\"ng-star-inserted\"\u003e. The unit also features a \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1949\"\u003ebuilt-in low battery indicator\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1979\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1734\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"1980\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1980\" class=\"ng-star-inserted\"\u003eOperational Details:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"1980\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1999\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"1999\" class=\"ng-star-inserted\"\u003eThe meter operates across three ranges up to 50,000 Lux\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2054\" class=\"ng-star-inserted\"\u003e. Measurement requires selecting the proper range (2,000 Lux, 20,000 Lux, or 50,000 Lux) and facing the light sensor towards the light source\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2195\" class=\"ng-star-inserted\"\u003e. The reading is displayed directly on the screen\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2244\" class=\"ng-star-inserted\"\u003e. The sampling time for the measurement is approximately 2 seconds\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2310\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2311\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"2393\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2393\" class=\"ng-star-inserted\"\u003eTechnical Specifications (WORKZONE LX-101):\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"2393\"\u003e \u003c\/div\u003e\n\u003ctable class=\"ng-star-inserted\" data-start-index=\"2435\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2435\"\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2435\" class=\"ng-star-inserted\"\u003eSpecification\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2448\"\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2448\" class=\"ng-star-inserted\"\u003eDetail\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2454\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2454\"\u003eModel Number\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2466\"\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2466\" class=\"ng-star-inserted\"\u003eLX-101\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2472\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2472\"\u003eType of Product\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2487\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2487\" class=\"ng-star-inserted\"\u003eDigital Lux Meter\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2504\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2504\"\u003eMeasurement Range\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2521\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2521\" class=\"ng-star-inserted\"\u003e0 to 50,000 Lux (3 ranges)\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2547\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2547\"\u003eRange A\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2554\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2554\" class=\"ng-star-inserted\"\u003e0 to 1,999 Lux\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2568\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2568\"\u003eRange B\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2575\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2575\" class=\"ng-star-inserted\"\u003e2,000 to 19,990 Lux\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2594\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2594\"\u003eRange C\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2601\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2601\" class=\"ng-star-inserted\"\u003e20,000 to 50,000 Lux\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2621\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2621\"\u003eResolution (Range-dependent)\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2649\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2649\" class=\"ng-star-inserted\"\u003e1 Lux (Range A), 10 Lux (Range B), 100 Lux (Range C)\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2701\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2701\"\u003eAccuracy (23±5°C)\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2718\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2718\" class=\"ng-star-inserted\"\u003e± (5% + 2 digits) across all ranges\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2753\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2753\"\u003eDisplay\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2760\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2760\" class=\"ng-star-inserted\"\u003eDigital LCD (Max. indication 1999)\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2794\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2794\"\u003eSensor\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2800\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2800\" class=\"ng-star-inserted\"\u003eExclusive photo diode \u0026amp; color correction filter\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2847\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2847\"\u003eSampling Time\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2860\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2860\" class=\"ng-star-inserted\"\u003e2 Seconds\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2869\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2869\"\u003eOver-input Indication\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2890\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2890\" class=\"ng-star-inserted\"\u003eIndication of \"1\"\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2907\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2907\"\u003ePower Supply\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2919\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2919\" class=\"ng-star-inserted\"\u003eDC 9V Battery (006P, MN 1604, PP3, or equivalent)\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2968\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2968\"\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2989\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"2989\" class=\"ng-star-inserted\"\u003e0 to 50°C (32 to 122°F)\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3012\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3012\"\u003eOperating Humidity\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3030\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"3030\" class=\"ng-star-inserted\"\u003eLess than 80% R.H.\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3048\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3048\"\u003ePower Consumption\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3065\"\u003e\n\u003cspan _ngcontent-ng-c1374534054=\"\" data-start-index=\"3065\" class=\"ng-star-inserted\"\u003eApprox. DC 2 mA\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-45\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1374534054=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Workzone","offers":[{"title":"Default Title","offer_id":51460974936310,"sku":"WZ-LUX- LX 101","price":2655.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/China_LX_101_LUX_METER__35320.1759835559.386.513.jpg?v=1786599172"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/collections\/lux-meters.png?v=1786700878","url":"https:\/\/scispectrum.in\/collections\/lux-meters.oembed","provider":"SciSpectrum Lab Essentials","version":"1.0","type":"link"}