{"title":"Melting Point Apparatus","description":"Digital melting point apparatus for pharmaceutical, chemical and quality-control melting point determination.","products":[{"product_id":"auto-melting-point-apparatus","title":"Auto Melting Point Apparatus Digital Lab Temperature Tester","description":"\u003cdiv class=\"powr-chat\" id=\"1abb102c_1753877895\"\u003e\u003c\/div\u003e\n\u003ch2\u003eAuto Melting Point Apparatus Digital Lab Temperature Tester\u003c\/h2\u003e\n\u003ch2\u003eAuto Melting Point Apparatus: Precision Crystalline Sample Analysis\u003c\/h2\u003e\nThe Auto Melting Point Apparatus is a sophisticated laboratory instrument specifically designed to determine the melting point temperature of crystalline samples with enhanced accuracy and reproducibility. Utilizing the latest microcontroller technology and advanced engineering techniques, this ISO 9001:2000 certified instrument delivers reliable results for pharmaceutical, chemical, and educational applications.\n\u003ch3\u003eKey Features \u0026amp; Benefits Auto Melting Point Apparatus\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAdvanced Digital Display\u003c\/strong\u003e - 4-digit seven segment LED display (Model 1935) or 3-digit display (Model 1934) for precise temperature readings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWide Temperature Range\u003c\/strong\u003e - Testing capability from ambient to 300°C for diverse sample analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSuperior Accuracy\u003c\/strong\u003e - ±1°C at 20°C and ±2.5°C at 300°C for reliable results\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProgrammable Plateau Temperature\u003c\/strong\u003e - Set temperature just below expected melting point for optimized testing\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAdjustable Ramp Rates\u003c\/strong\u003e - Programmable on a scale of 1-10 to customize heating progression\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMemory Storage\u003c\/strong\u003e - Retain up to 100 test results even when powered off\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePlatinum Resistance Sensor\u003c\/strong\u003e - High-quality Pt100 sensor for accurate temperature measurement\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUser-Friendly Interface\u003c\/strong\u003e - Soft touch membrane keys for intuitive operation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuick Cooling System\u003c\/strong\u003e - Integrated fan for rapid cooling between tests\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAudio-Visual Indicators\u003c\/strong\u003e - Clear status LEDs (PLATEAU, °C, RAMP, RUN, END, READY \u0026amp; RECALL) with audible alerts\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCapillary Cleaning Feature\u003c\/strong\u003e - Normal\/Clean rotary switch for safe removal of broken capillaries\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOptimized Heating Block\u003c\/strong\u003e - Aluminum block design for consistent heat distribution\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eResolution Options\u003c\/strong\u003e - 0.1°C resolution (Model 1935) or 1°C resolution (Model 1934)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eISO 9001:2000 Certification\u003c\/strong\u003e - Guaranteed quality construction and performance\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e1-Year Warranty\u003c\/strong\u003e - Comprehensive coverage for reliability and peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1935 (4-digit display, 0.1°C resolution)\n1934 (3-digit display, 1°C resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Sample at a Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient to 300°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1°C at 20°C\n±2.5°C at 300°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlatinum Resistance Pt100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRamp Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable at Scale of 1-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlateau Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModel 1935: 4-Digit Seven Segment LED Display\nModel 1934: 3-Digit Seven Segment LED Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModel 1935: 0.1°C\nModel 1934: 1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft Touch Membrane Keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLATEAU, °C, RAMP, RUN, END, READY \u0026amp; RECALL LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 100 Results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 230 V ±10%, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.0 Kg (Approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBox of Capillaries, Operation Manual \u0026amp; Dust Cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003ch4\u003eIntelligent Testing Process Auto Melting Point Apparatus\u003c\/h4\u003e\nThe Auto Melting Point Apparatus employs a sophisticated testing methodology that optimizes both speed and accuracy:\n\u003col\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSample Preparation\u003c\/strong\u003e - The crystalline sample is placed within capillary tubes\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCapillary Placement\u003c\/strong\u003e - Sample tube is inserted into the aluminum heating block within the heating chamber\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eParameter Programming\u003c\/strong\u003e - User sets the plateau temperature (just below expected melting point) and desired ramp rate\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRapid Initial Heating\u003c\/strong\u003e - System quickly heats to the programmed plateau temperature\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eControlled Temperature Ramping\u003c\/strong\u003e - Once plateau is reached, temperature increases at the programmed rate until melting occurs\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnd Point Detection\u003c\/strong\u003e - The final melting point temperature is displayed with visual (\"END\" LED) and audible indicators\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eResult Storage\u003c\/strong\u003e - Temperature reading can be stored in memory (up to 100 results)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRapid Cooling\u003c\/strong\u003e - Integrated fan allows quick cooling for subsequent tests\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003eAdvanced Control Features Auto Melting Point Apparatus\u003c\/h4\u003e\nThe microcontroller-based system provides several advantages for precise melting point determination:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTwo-Phase Heating\u003c\/strong\u003e - Rapid heating to plateau followed by precise controlled ramping maximizes efficiency and accuracy\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProgrammable Ramp Rates\u003c\/strong\u003e - Adjustable heating rates (scale 1-10) allow customization for different sample types\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOptimized Heating Block\u003c\/strong\u003e - Aluminum block design ensures uniform heat distribution around the capillary tube\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePlatinum Resistance Sensing\u003c\/strong\u003e - High-quality Pt100 sensor provides accurate temperature monitoring throughout the heating cycle\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eIntuitive Status Indicators\u003c\/strong\u003e - Clear LED indicators (PLATEAU, °C, RAMP, RUN, END, READY \u0026amp; RECALL) show current operation phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications Auto Melting Point Apparatus\u003c\/h3\u003e\n\u003ch4\u003ePharmaceutical Research \u0026amp; Quality Control\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRaw Material Verification\u003c\/strong\u003e - Confirm identity and purity of pharmaceutical ingredients\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompound Characterization\u003c\/strong\u003e - Determine physical properties of new synthesized compounds\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuality Control\u003c\/strong\u003e - Verify consistency and purity of manufactured products\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStability Testing\u003c\/strong\u003e - Monitor changes in physical properties during stability studies\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePolymorphism Detection\u003c\/strong\u003e - Identify different crystalline forms of the same compound\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eChemical Analysis \u0026amp; Research Auto Melting Point Apparatus\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOrganic Compound Identification\u003c\/strong\u003e - Characterize synthesized or isolated organic materials\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePurity Assessment\u003c\/strong\u003e - Evaluate sample purity through melting point depression\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEutectic Mixture Analysis\u003c\/strong\u003e - Determine composition of binary mixtures\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eNew Material Development\u003c\/strong\u003e - Characterize properties of newly developed compounds\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuality Verification\u003c\/strong\u003e - Confirm specifications of purchased chemicals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEducational Applications Auto Melting Point Apparatus\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eChemistry Laboratory Instruction\u003c\/strong\u003e - Teach fundamental analytical techniques to students\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eResearch Methods Training\u003c\/strong\u003e - Demonstrate proper material characterization procedures\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStudent Research Projects\u003c\/strong\u003e - Support undergraduate and graduate research activities\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompound Identification Exercises\u003c\/strong\u003e - Enhance laboratory curriculum with identification challenges\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePhysical Property Demonstrations\u003c\/strong\u003e - Illustrate concepts of phase changes and crystalline structures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eGeneral Laboratory Use Auto Melting Point Apparatus\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWax and Polymer Analysis\u003c\/strong\u003e - Determine melting points of various industrial materials\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFood Science Applications\u003c\/strong\u003e - Analyze crystalline food components like fats and sugars\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eForensic Analysis\u003c\/strong\u003e - Aid in identification of unknown crystalline substances\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuality Assurance Programs\u003c\/strong\u003e - Support general laboratory QA\/QC procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Advantages for Laboratory Use\u003c\/h3\u003e\n\u003ch4\u003eTime-Efficient Testing Auto Melting Point Apparatus\u003c\/h4\u003e\nThe Auto Melting Point Apparatus streamlines the testing process through several innovative features:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTwo-Phase Heating System\u003c\/strong\u003e - Rapid initial heating followed by precise controlled ramping saves time\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProgrammable Parameters\u003c\/strong\u003e - Store frequently used testing protocols for quick setup\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eIntegrated Cooling Fan\u003c\/strong\u003e - Reduces downtime between consecutive tests\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuick Sample Loading\u003c\/strong\u003e - Simple capillary tube insertion system\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEasy Cleaning Procedure\u003c\/strong\u003e - Normal\/Clean rotary switch for quick removal of broken capillaries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnhanced Accuracy \u0026amp; Reliability Auto Melting Point Apparatus\u003c\/h4\u003e\nSeveral design elements contribute to superior measurement performance:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePlatinum Resistance Temperature Sensor\u003c\/strong\u003e - Industry-standard Pt100 sensor for precise readings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOptimized Heating Block\u003c\/strong\u003e - Uniform heat distribution throughout the sample area\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eControlled Ramp Rates\u003c\/strong\u003e - Customizable heating progression based on sample properties\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Display\u003c\/strong\u003e - Clear temperature readings with 0.1°C resolution (Model 1935)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMicrocontroller Regulation\u003c\/strong\u003e - Digital precision throughout the heating cycle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eUser-Friendly Operation Auto Melting Point Apparatus\u003c\/h4\u003e\nDesigned for intuitive use in busy laboratory environments:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMembrane Keypad\u003c\/strong\u003e - Durable, easy-to-clean soft touch controls\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStatus Indicator LEDs\u003c\/strong\u003e - Clear visual cues for current operation phase\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAudible Alerts\u003c\/strong\u003e - End-of-test notification without constant monitoring\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eResult Storage\u003c\/strong\u003e - Convenient access to previous test data\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSimple Parameter Adjustment\u003c\/strong\u003e - Intuitive up\/down keys for quick setting changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eData Management Capabilities Auto Melting Point Apparatus\u003c\/h4\u003e\nComprehensive result handling features support laboratory documentation needs:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e100-Result Memory\u003c\/strong\u003e - Store multiple test results for later review\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eNon-Volatile Storage\u003c\/strong\u003e - Results retained even when power is off\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSimple Recall Function\u003c\/strong\u003e - Easy access to stored data\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eClear Visual Display\u003c\/strong\u003e - Bright LED readout of current and stored results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperating Instructions Auto Melting Point Apparatus\u003c\/h3\u003e\n\u003col\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eInstrument Preparation\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003ePlace the instrument on a stable, level surface\u003c\/li\u003e\n \t\u003cli\u003eConnect to power supply (AC 230V ±10%, 50Hz)\u003c\/li\u003e\n \t\u003cli\u003eSwitch on the power and allow system to initialize\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSample Preparation\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eCrush the crystalline sample into a fine powder\u003c\/li\u003e\n \t\u003cli\u003eFill the capillary tube with 2-3mm of sample\u003c\/li\u003e\n \t\u003cli\u003eTap the tube gently to settle the sample at the bottom\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eParameter Setting\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003ePress the 'Plateau' key and use 'Up'\/'Down' keys to set temperature slightly below expected melting point\u003c\/li\u003e\n \t\u003cli\u003ePress the 'Ramp' key and use 'Up'\/'Down' keys to set the desired heating rate (1-10)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTest Execution\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eInsert the prepared capillary tube into the heating block\u003c\/li\u003e\n \t\u003cli\u003eStart the test cycle - 'RUN' LED will illuminate\u003c\/li\u003e\n \t\u003cli\u003eSystem will heat rapidly to plateau temperature then ramp at programmed rate\u003c\/li\u003e\n \t\u003cli\u003eObserve the sample through viewing window for melting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eResult Management\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eWhen melting occurs, the 'END' LED will illuminate with audible alerts\u003c\/li\u003e\n \t\u003cli\u003eFinal temperature will be displayed on the LED screen\u003c\/li\u003e\n \t\u003cli\u003eTo store result, press 'Store\/Recall' key\u003c\/li\u003e\n \t\u003cli\u003eTo review stored results, use 'Store\/Recall' key in combination with 'Up'\/'Down' keys\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSystem Reset\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eAllow system to cool with built-in fan before next test\u003c\/li\u003e\n \t\u003cli\u003eIf capillary breaks, use 'Normal'\/'Clean' rotary switch to flush broken glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMaintenance \u0026amp; Care Auto Melting Point Apparatus\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRegular Cleaning\u003c\/strong\u003e - Keep the heating chamber and viewing window clean for optimal visibility\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCapillary Management\u003c\/strong\u003e - Promptly remove broken capillaries using the Clean function\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eVentilation\u003c\/strong\u003e - Ensure adequate airflow around the instrument for proper cooling\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDust Protection\u003c\/strong\u003e - Use the included dust cover when not in operation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePeriodic Verification\u003c\/strong\u003e - Check temperature accuracy with known standard materials\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eKeyboard Care\u003c\/strong\u003e - Clean membrane keypad with slightly damp cloth; avoid solvents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAbout Electronics India Auto Melting Point Apparatus\u003c\/h3\u003e\nElectronics India is an ISO 9001:2000 certified manufacturer of precision laboratory and analytical equipment. With a comprehensive product range that includes spectrophotometers, analytical instruments, testing apparatus, and laboratory equipment, the company has established a reputation for delivering reliable, high-quality instruments for research, educational, and industrial applications.\n\nTheir commitment to quality is demonstrated through ISO certification and comprehensive warranty coverage. Electronics India continues to develop innovative solutions for analytical testing needs across pharmaceutical, chemical, educational, and research sectors.\n\u003ch3\u003eAdditional Products in the Electronics India Range\u003c\/h3\u003e\nElectronics India offers a complete line of analytical and testing equipment including:\n\u003cul\u003e\n \t\u003cli\u003eUV\/VIS Spectrophotometers (Single and Double Beam)\u003c\/li\u003e\n \t\u003cli\u003eSemi-Auto Analyzers\u003c\/li\u003e\n \t\u003cli\u003eFlame Photometers and Hemoglobin Meters\u003c\/li\u003e\n \t\u003cli\u003ePhoto Colorimeters and Fluorometers\u003c\/li\u003e\n \t\u003cli\u003epH, Conductivity, TDS, DO, and Salinity Meters\u003c\/li\u003e\n \t\u003cli\u003eDissolution and Disintegration Test Apparatus\u003c\/li\u003e\n \t\u003cli\u003eFriability Test Apparatus\u003c\/li\u003e\n \t\u003cli\u003eTurbidity Meters and Nephelometers\u003c\/li\u003e\n \t\u003cli\u003eKarl Fischer Moisture Titrators\u003c\/li\u003e\n \t\u003cli\u003eWater \u0026amp; Soil Analysis Kits\u003c\/li\u003e\n \t\u003cli\u003ePortable Testing Equipment\u003c\/li\u003e\n \t\u003cli\u003eVarious Microscopes (Student, Binocular, Medical, Co-Axial)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ: Auto Melting Point Apparatus\u003c\/h3\u003e\n\u003ch4\u003eWhy is the plateau temperature function important? Auto Melting Point Apparatus\u003c\/h4\u003e\nThe plateau temperature function allows the system to rapidly heat to a temperature just below the expected melting point, then switch to a slower, more controlled heating rate. This two-phase approach saves time during the initial heating while ensuring the critical melting transition occurs during a precisely controlled temperature ramp for maximum accuracy.\n\u003ch4\u003eWhat is the difference between Models 1935 and 1934? Auto Melting Point Apparatus\u003c\/h4\u003e\nThe primary differences are in display resolution and precision. Model 1935 features a 4-digit display with 0.1°C resolution for more precise readings, while Model 1934 has a 3-digit display with 1°C resolution. Both models share the same fundamental features, temperature range, and memory capabilities.\n\u003ch4\u003eHow does the memory function work? Auto Melting Point Apparatus\u003c\/h4\u003e\nThe apparatus can store up to 100 melting point results in its non-volatile memory, which retains data even when powered off. Users can access these stored results using the 'Store\/Recall' key in combination with the 'Up'\/'Down' keys, allowing comparison of current readings with previous tests.\n\u003ch4\u003eWhat safety features does the apparatus include? Auto Melting Point Apparatus\u003c\/h4\u003e\nSafety features include the specialized cleaning function for safely removing broken capillaries, integrated cooling fan to reduce surface temperatures between tests, clear status indicators to show current operation phase, and a durable design with no exposed heating elements.\n\u003ch4\u003eIs temperature calibration possible? Auto Melting Point Apparatus\u003c\/h4\u003e\nWhile the instrument comes factory calibrated, periodic verification using known standard materials with established melting points is recommended. For full recalibration, please contact the manufacturer or authorized service representative.\n\u003ch3\u003eSummary Auto Melting Point Apparatus\u003c\/h3\u003e\nThe Auto Melting Point Apparatus by Electronics India represents a significant advancement in melting point determination technology for laboratory applications. With its microcontroller-based design, programmable plateau temperatures, adjustable ramp rates, and comprehensive data storage capabilities, this instrument delivers the precision and reliability required for pharmaceutical, chemical, and educational testing environments.\n\nAvailable in two models—the high-resolution 1935 (0.1°C resolution) and standard 1934 (1°C resolution)—the apparatus accommodates various laboratory requirements and budgetary considerations while maintaining essential functionality. The innovative two-phase heating approach with programmable parameters optimizes both testing efficiency and result accuracy.\n\nKey advantages include the wide temperature range (ambient to 300°C), platinum resistance temperature sensing, intuitive user interface with membrane keys, and capacity to store up to 100 test results. The system's audio-visual indicators, integrated cooling fan, and specialized cleaning function further enhance usability in busy laboratory settings.\n\nAs an ISO 9001:2000 certified product with a comprehensive one-year warranty, the Auto Melting Point Apparatus delivers professional-grade performance for melting point determination across a wide range of crystalline samples. Its balance of technological sophistication, user-friendly operation, and reliable construction makes it an excellent choice for any laboratory requiring precise melting point analysis.","brand":"Electronics India","offers":[{"title":"EI1934","offer_id":51461006786806,"sku":"EI1934\/1935-EI","price":62422.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Auto_Melting_Point_Apparatus_Digital_Lab_Temperature_Tester__27873.1754463225.386.513_c68410be-94df-48e3-b7ba-75a2e848f665.jpg?v=1786598885"},{"product_id":"digital-melting-point-apparatus","title":"Digital Melting Point Apparatus","description":"\u003cdiv class=\"powr-chat\" id=\"1abb102c_1753877895\"\u003e\u003c\/div\u003e\n\u003ch2\u003eDigital Melting Point Apparatus\u003c\/h2\u003e\n\u003ch2\u003eDigital Melting Point Apparatus: Precision Temperature Analysis for Laboratory Applications\u003c\/h2\u003e\nThe Digital Melting Point Apparatus is a sophisticated laboratory instrument specifically designed for accurate measurement of melting points and melting ranges of solid samples. This ISO 9001:2000 certified equipment delivers exceptional precision for pharmaceutical, chemical, and educational laboratories requiring reliable crystalline sample analysis.\n\u003ch3\u003eKey Features \u0026amp; Benefits Digital Melting Point Apparatus\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh-Precision Temperature Display\u003c\/strong\u003e - 4-digit seven segment red LED display with model-specific resolution (0.1°C in model 935, 1°C in model 934)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWide Temperature Range\u003c\/strong\u003e - Testing capability from ambient to 300°C for diverse sample analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSilicon Oil Bath System\u003c\/strong\u003e - 200ml capacity bath with Teflon cover ensures uniform heat distribution\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eIntegrated Magnetic Stirrer\u003c\/strong\u003e - Built-in stirring capability with adjustable speed for consistent temperature throughout the oil bath\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSpecialized Teflon Cover\u003c\/strong\u003e - Features 5 strategic openings for capillaries (3), boiling point tube (1), and thermometer (1)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnhanced Visibility\u003c\/strong\u003e - Large magnifier and glare-free background illuminator for strain-free sample observation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePrecision Heating Control\u003c\/strong\u003e - Electronic controller with indicator for precise adjustment of heating rate\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePlatinum Resistance Sensor\u003c\/strong\u003e - PT-100 RTD sensor for accurate temperature measurement\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSimple Operation\u003c\/strong\u003e - Intuitive Start\/Stop\/Clear controls for straightforward testing procedure\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTemperature Range Selector\u003c\/strong\u003e - High\/Low range selector switch for optimized measurement control\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMemory Function\u003c\/strong\u003e - Display retains last measured temperature reading for reference\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSpecial Immersion Heater\u003c\/strong\u003e - Designed specifically for optimal oil bath heating characteristics\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompact Design\u003c\/strong\u003e - Space-efficient laboratory footprint (315 × 290 × 230mm)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eISO 9001:2000 Certification\u003c\/strong\u003e - Guaranteed quality construction and performance\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e1-Year Warranty\u003c\/strong\u003e - Comprehensive coverage for reliability and peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Digital Melting Point Apparatus\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e935 (0.1°C resolution)\n934 (1°C resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-300°C on a 4-digit LED display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModel 935: 0.1°C\nModel 934: 1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePT-100 RTD sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOil Bath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon oil bath - 200 ml capacity\nTeflon cover with three capillary holes, one boiling point tube hole, and one thermometer hole\nIncludes special oil immersion heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStirrer Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControllable with front knob\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapillary Glass Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12mm long, 0.8 to 1.1mm internal diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFine powder properly dried at a temperature considerably below its melting point, 4 to 6 mm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 × 290 × 230mm (L×B×H) (Approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V ±10% AC, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Kg. (Approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStart, Stop, Clear switches\nHigh\/Low range temperature selector\nHeating rate controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit seven segment red LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 9001:2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIncluded Accessories Digital Melting Point Apparatus\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003eBox of Capillaries\u003c\/li\u003e\n \t\u003cli\u003eGlass Tubes for Liquid Sample (6 × 75 mm) - 2 Nos.\u003c\/li\u003e\n \t\u003cli\u003eMagnetic Capsule\u003c\/li\u003e\n \t\u003cli\u003eBottle of Silicon Oil - 250 ml\u003c\/li\u003e\n \t\u003cli\u003eGlass Cylindrical Beaker with Teflon cover fitted with immersion heater\u003c\/li\u003e\n \t\u003cli\u003eInstruction Manual\u003c\/li\u003e\n \t\u003cli\u003eDust Cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003ch4\u003ePrecision Testing Process Digital Melting Point Apparatus\u003c\/h4\u003e\nThe Digital Melting Point Apparatus employs a methodical approach to melting point determination:\n\u003col\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSample Preparation\u003c\/strong\u003e - The solid sample is finely powdered and dried at a temperature well below its melting point\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCapillary Loading\u003c\/strong\u003e - A 4-6mm column of sample is loaded into glass capillary tubes\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBath Setup\u003c\/strong\u003e - The silicon oil bath is filled and the magnetic stirrer activated to ensure uniform temperature distribution\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCapillary Placement\u003c\/strong\u003e - Sample-filled capillaries are inserted into the designated holes in the Teflon cover\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTemperature Control\u003c\/strong\u003e - The heating rate is adjusted using the electronic controller\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMeasurement Initiation\u003c\/strong\u003e - The 'Start' switch is pressed to begin temperature monitoring\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSample Observation\u003c\/strong\u003e - The sample is viewed through the magnifier and illuminator to observe phase changes\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eResult Recording\u003c\/strong\u003e - When melting occurs, the 'Stop' switch is pressed to capture the temperature reading\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTemperature Display\u003c\/strong\u003e - The 4-digit LED display shows the temperature at which the sample melted\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003eSilicon Oil Bath Technology Digital Melting Point Apparatus\u003c\/h4\u003e\nThe heart of the Digital Melting Point Apparatus is its sophisticated oil bath system:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUniform Heat Distribution\u003c\/strong\u003e - The 200ml silicon oil bath provides consistent temperature throughout the testing environment\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eIntegrated Magnetic Stirring\u003c\/strong\u003e - Continuous stirring eliminates temperature gradients within the oil bath\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSpecialized Immersion Heater\u003c\/strong\u003e - Custom-designed heater ensures optimal heat transfer to the oil\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePrecise Temperature Control\u003c\/strong\u003e - Electronic controller allows fine adjustment of heating rate\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePT-100 RTD Sensor\u003c\/strong\u003e - Professional-grade platinum resistance temperature detector provides accurate readings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTeflon Cover Design\u003c\/strong\u003e - Strategic placement of openings allows proper alignment of capillaries for observation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003ch4\u003ePharmaceutical Quality Control Digital Melting Point Apparatus\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRaw Material Verification\u003c\/strong\u003e - Confirm identity and purity of pharmaceutical ingredients\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBatch Quality Testing\u003c\/strong\u003e - Ensure consistent quality of manufactured compounds\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUSP\/EP\/JP Compliance\u003c\/strong\u003e - Meet pharmacopeia requirements for melting point determination\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStability Testing\u003c\/strong\u003e - Monitor physical property changes during stability studies\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePolymorphism Detection\u003c\/strong\u003e - Identify different crystalline forms of the same compound\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eChemical Analysis \u0026amp; Research\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompound Identification\u003c\/strong\u003e - Characterize synthesized or isolated compounds\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePurity Assessment\u003c\/strong\u003e - Evaluate sample purity through melting range analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEutectic Mixture Analysis\u003c\/strong\u003e - Determine composition through melting behavior\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCrystallization Studies\u003c\/strong\u003e - Analyze crystallization patterns and properties\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuality Verification\u003c\/strong\u003e - Confirm specifications of purchased chemicals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEducational Applications Digital Melting Point Apparatus\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLaboratory Instruction\u003c\/strong\u003e - Teach fundamental analytical techniques to students\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePhysical Chemistry Demonstrations\u003c\/strong\u003e - Illustrate principles of phase transitions\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOrganic Chemistry Labs\u003c\/strong\u003e - Support compound identification and purity assessment\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStudent Research Projects\u003c\/strong\u003e - Provide reliable equipment for undergraduate and graduate research\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTechnique Development\u003c\/strong\u003e - Build skills in physical property determination\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIndustrial Quality Control\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWax and Polymer Testing\u003c\/strong\u003e - Determine melting characteristics of industrial materials\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFood Science Applications\u003c\/strong\u003e - Analyze fats, lipids, and crystalline food components\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMaterial Verification\u003c\/strong\u003e - Confirm consistency of incoming materials\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProduct Development\u003c\/strong\u003e - Characterize properties of new formulations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Advantages for Laboratory Use\u003c\/h3\u003e\n\u003ch4\u003eSuperior Accuracy \u0026amp; Precision Digital Melting Point Apparatus\u003c\/h4\u003e\nThe Digital Melting Point Apparatus delivers exceptional measurement quality through several key design features:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Digital Display\u003c\/strong\u003e - Model 935 provides 0.1°C resolution for detailed analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePT-100 RTD Sensor\u003c\/strong\u003e - Laboratory-grade platinum resistance sensor ensures accurate readings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUniform Oil Bath Heating\u003c\/strong\u003e - Magnetic stirring eliminates temperature gradients\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eControlled Heating Rate\u003c\/strong\u003e - Adjustable heating allows optimization for different sample types\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnhanced Visibility\u003c\/strong\u003e - Magnifier and glare-free illumination for precise observation of phase changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eUser-Friendly Operation Digital Melting Point Apparatus\u003c\/h4\u003e\nDesigned for straightforward use in busy laboratory environments:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eIntuitive Controls\u003c\/strong\u003e - Simple Start\/Stop\/Clear operation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eClear Digital Readout\u003c\/strong\u003e - Bright LED display shows temperature readings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMemory Feature\u003c\/strong\u003e - Last temperature reading is retained until cleared\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAdjustable Stirring Speed\u003c\/strong\u003e - Front knob control for easy adjustment\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh\/Low Range Selector\u003c\/strong\u003e - Optimizes measurement for different temperature ranges\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eVisual Indicators\u003c\/strong\u003e - Pilot lamp shows operational status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePractical Laboratory Design Digital Melting Point Apparatus\u003c\/h4\u003e\nEngineered for the realities of daily laboratory use:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompact Footprint\u003c\/strong\u003e - Efficient use of valuable bench space\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eComplete Accessory Package\u003c\/strong\u003e - All necessary components included\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMultiple Sample Testing\u003c\/strong\u003e - Three capillary positions allow simultaneous testing\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBoiling Point Capability\u003c\/strong\u003e - Dedicated position for boiling point tube\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDurable Construction\u003c\/strong\u003e - Built for continuous laboratory operation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eProtective Dust Cover\u003c\/strong\u003e - Safeguards instrument when not in use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperating Instructions Digital Melting Point Apparatus\u003c\/h3\u003e\n\u003col\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eInstrument Setup\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003ePlace the apparatus on a flat, stable surface\u003c\/li\u003e\n \t\u003cli\u003eFill the bath with silicon oil to the appropriate level (approximately 200ml)\u003c\/li\u003e\n \t\u003cli\u003eConnect to power supply (230V ±10% AC, 50Hz)\u003c\/li\u003e\n \t\u003cli\u003eTurn on the instrument using the ON\/OFF switch (pilot lamp will illuminate)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSample Preparation\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eGrind the solid sample into a fine powder\u003c\/li\u003e\n \t\u003cli\u003eEnsure sample is completely dry (pre-dry if necessary at temperature well below melting point)\u003c\/li\u003e\n \t\u003cli\u003ePack capillary tube by gently tapping open end into the powdered sample\u003c\/li\u003e\n \t\u003cli\u003eEnsure sample column height is 4-6mm at bottom of capillary\u003c\/li\u003e\n \t\u003cli\u003eTap capillary on hard surface to compact the sample at the closed end\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTesting Procedure\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eInsert loaded capillaries into designated holes in the Teflon cover\u003c\/li\u003e\n \t\u003cli\u003eSet the High\/Low range temperature selector switch as appropriate\u003c\/li\u003e\n \t\u003cli\u003eAdjust the heating rate using the electronic controller\u003c\/li\u003e\n \t\u003cli\u003eActivate the magnetic stirrer and adjust speed with the front knob\u003c\/li\u003e\n \t\u003cli\u003ePress the 'Start' switch to begin temperature monitoring\u003c\/li\u003e\n \t\u003cli\u003eObserve the sample through the magnifier with illumination\u003c\/li\u003e\n \t\u003cli\u003eWhen melting begins, note the temperature on the digital display\u003c\/li\u003e\n \t\u003cli\u003eWhen melting is complete, press the 'Stop' switch\u003c\/li\u003e\n \t\u003cli\u003eRecord the final temperature shown on the display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSystem Reset Digital Melting Point Apparatus\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003ePress 'Clear' switch to reset the display for the next test\u003c\/li\u003e\n \t\u003cli\u003eAllow the oil bath to cool before removing samples or changing capillaries\u003c\/li\u003e\n \t\u003cli\u003eTurn off the instrument when testing is complete\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMaintenance \u0026amp; Care Digital Melting Point Apparatus\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOil Bath Maintenance\u003c\/strong\u003e - Replace silicon oil periodically or when discolored\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCleaning\u003c\/strong\u003e - Keep the illuminator and magnifier clean for clear observation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCapillary Management\u003c\/strong\u003e - Dispose of used capillaries properly; never reuse\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTemperature Verification\u003c\/strong\u003e - Periodically check accuracy with certified reference materials\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStirrer Care\u003c\/strong\u003e - Ensure magnetic capsule is clean and rotates freely\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSurface Cleaning\u003c\/strong\u003e - Wipe external surfaces with slightly damp cloth; avoid solvents\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStorage\u003c\/strong\u003e - Use the provided dust cover when instrument is not in use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAbout Electronics India Digital Melting Point Apparatus\u003c\/h3\u003e\nElectronics India is an ISO 9001:2000 certified manufacturer of precision laboratory and analytical equipment. With a comprehensive product range that includes spectrophotometers, analytical instruments, testing apparatus, and laboratory equipment, the company has established a reputation for delivering reliable, high-quality instruments for pharmaceutical, research, educational, and industrial applications.\n\nTheir commitment to quality is demonstrated through ISO certification and comprehensive warranty coverage. Electronics India continues to develop innovative solutions for analytical testing needs across various sectors, combining precision technology with practical laboratory functionality.\n\u003ch3\u003eAdditional Products in the Electronics India Range\u003c\/h3\u003e\nElectronics India offers a complete line of analytical and testing equipment including:\n\u003cul\u003e\n \t\u003cli\u003eUV\/VIS Spectrophotometers (Single and Double Beam)\u003c\/li\u003e\n \t\u003cli\u003eSemi-Auto Analyzers\u003c\/li\u003e\n \t\u003cli\u003eFlame Photometers and Hemoglobin Meters\u003c\/li\u003e\n \t\u003cli\u003ePhoto Colorimeters and Fluorometers\u003c\/li\u003e\n \t\u003cli\u003epH, Conductivity, TDS, DO, and Salinity Meters\u003c\/li\u003e\n \t\u003cli\u003eDissolution and Disintegration Test Apparatus\u003c\/li\u003e\n \t\u003cli\u003eFriability Test Apparatus\u003c\/li\u003e\n \t\u003cli\u003eTurbidity Meters and Nephelometers\u003c\/li\u003e\n \t\u003cli\u003eColony Counters\u003c\/li\u003e\n \t\u003cli\u003eKarl Fischer Moisture Titrators\u003c\/li\u003e\n \t\u003cli\u003eTelethermometers and Temperature Indicators\u003c\/li\u003e\n \t\u003cli\u003eWater \u0026amp; Soil Analysis Kits\u003c\/li\u003e\n \t\u003cli\u003ePortable Testing Equipment\u003c\/li\u003e\n \t\u003cli\u003eVarious Microscopes (Student, Binocular, Medical, Co-Axial)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ: Digital Melting Point Apparatus\u003c\/h3\u003e\n\u003ch4\u003eWhat is the difference between models 935 and 934? Digital Melting Point Apparatus\u003c\/h4\u003e\nThe primary difference is in display resolution. Model 935 offers higher precision with 0.1°C resolution, which is ideal for applications requiring more detailed temperature analysis. Model 934 provides 1°C resolution, which is suitable for general laboratory use and educational applications. Both models share the same core features, temperature range, and functionality.\n\u003ch4\u003eWhy is a silicon oil bath used rather than other heating methods? Digital Melting Point Apparatus\u003c\/h4\u003e\nSilicon oil provides several advantages for melting point determination: it offers excellent heat capacity and distribution properties, maintains uniform temperature throughout the bath (especially with magnetic stirring), allows clear visibility of samples, has a high boiling point suitable for the full temperature range, and provides stable, controlled heating characteristics essential for precise melting point measurement.\n\u003ch4\u003eHow does the magnetic stirrer improve measurement accuracy? Digital Melting Point Apparatus\u003c\/h4\u003e\nThe integrated magnetic stirrer ensures uniform temperature distribution throughout the oil bath by preventing temperature stratification (layering). Without stirring, temperature gradients could develop where the oil near the heating element becomes hotter than oil at the sample position, leading to inaccurate readings. Constant stirring maintains consistent temperature throughout the bath for more reliable measurements.\n\u003ch4\u003eCan this apparatus test both melting points and boiling points? Digital Melting Point Apparatus\u003c\/h4\u003e\nYes, the apparatus is designed to measure both. The Teflon cover has specific positions for three capillary tubes (for solid sample melting points) and one dedicated position for a boiling point tube (for liquid sample boiling points). The included accessories package contains both standard capillaries and specialized glass tubes (6 × 75 mm) for liquid sample testing.\n\u003ch4\u003eWhat is the purpose of the High\/Low range temperature selector? Digital Melting Point Apparatus\u003c\/h4\u003e\nThe High\/Low range selector optimizes the heating control characteristics for different temperature ranges. For lower melting point samples, the Low range selection provides more precise control and finer temperature adjustment in the lower temperature ranges. For higher melting point samples, the High range selection is optimized for the upper temperature spectrum, ensuring accurate readings throughout the full 0-300°C range.\n\u003ch3\u003eSummary Digital Melting Point Apparatus\u003c\/h3\u003e\nThe Digital Melting Point Apparatus by Electronics India represents an excellent balance of precision, functionality, and value for laboratories requiring reliable melting point determination. Available in two models—the high-resolution 935 (0.1°C) and standard 934 (1°C)—this ISO 9001:2000 certified instrument delivers accurate results for pharmaceutical quality control, chemical analysis, educational applications, and industrial testing.\n\nThe system's key advantages include its silicon oil bath with integrated magnetic stirrer for uniform heating, 4-digit LED display for clear temperature readings, enhanced sample visibility through magnifier and glare-free illumination, and simple operation with intuitive controls. The comprehensive accessory package, including capillaries, glass tubes for liquid samples, magnetic capsule, and silicon oil, ensures the apparatus is ready for immediate use.\n\nWith its compact design (315 × 290 × 230mm), reasonable weight (12 kg), and complete feature set, the Digital Melting Point Apparatus offers excellent laboratory value while maintaining the precision and reliability required for critical testing applications. The instrument's temperature range of 0-300°C accommodates most laboratory melting point determination needs, while the specialized Teflon cover with multiple sample positions allows efficient workflow.\n\nBacked by Electronics India's reputation for quality instrumentation and protected by a 1-year warranty, the Digital Melting Point Apparatus delivers professional-grade performance for melting point analysis across a wide range of solid samples, making it an essential tool for any quality-focused laboratory.","brand":"Electronics India","offers":[{"title":"EI935","offer_id":51461006819574,"sku":"EI935\/934-EI","price":48262.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Digital_Melting_Point_Apparatus__53976.1754463668.386.513_5006a632-372a-44e9-bc60-2ac1db8b157c.jpg?v=1786598897"},{"product_id":"melting-point-apparatus-931","title":"EI-DVI Model 931 Melting Point Apparatus","description":"\u003cdiv class=\"powr-chat\" id=\"1abb102c_1753877895\"\u003e\u003c\/div\u003e\n\u003ch2\u003eMelting Point Apparatus 931\u003c\/h2\u003e\n\u003ch2\u003eMelting Point Apparatus Model 931: Precision Temperature Analysis for Laboratory Applications\u003c\/h2\u003e\nThe Melting Point Apparatus Model 931 is a professional laboratory instrument specifically designed for accurate measurement of melting points and melting ranges of solid samples. This ISO 9001:2000 certified equipment delivers reliable results for pharmaceutical, chemical, and educational laboratories requiring precise crystalline sample analysis and quality control testing.\n\u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWide Temperature Range\u003c\/strong\u003e - Testing capability from 0-300°C for diverse sample analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSilicon Oil Bath System\u003c\/strong\u003e - 200ml capacity bath with Teflon cover ensures uniform heat distribution\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eIntegrated Magnetic Stirrer\u003c\/strong\u003e - Built-in stirring capability with adjustable speed for consistent temperature throughout the oil bath\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMulti-Sample Testing\u003c\/strong\u003e - Specialized Teflon cover with three capillary holes for simultaneous sample testing\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eVersatile Testing Capability\u003c\/strong\u003e - Additional dedicated positions for boiling point tube and thermometer\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnhanced Visibility\u003c\/strong\u003e - Large magnifier and glare-free background illuminator for strain-free sample observation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePrecision Heating Control\u003c\/strong\u003e - Indicator for precise adjustment of silicon oil-bath heating rate\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDual Range Selection\u003c\/strong\u003e - High\/low range temperature selector switch for optimized measurement control\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSpecial Immersion Heater\u003c\/strong\u003e - Designed specifically for optimal oil bath heating characteristics\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eComplete Measurement System\u003c\/strong\u003e - Includes 0-360°C thermometer for accurate temperature readings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompact Design\u003c\/strong\u003e - Space-efficient laboratory footprint (235 × 285 × 160mm)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLightweight Construction\u003c\/strong\u003e - Approximately 8.7kg for easy positioning in the laboratory\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eISO 9001:2000 Certification\u003c\/strong\u003e - Guaranteed quality construction and performance\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003e1-Year Warranty\u003c\/strong\u003e - Comprehensive coverage for reliability and peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Melting Point Apparatus 931\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e931\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-300°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-360°C thermometer (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOil Bath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon oil bath - 200 ml capacity\nTeflon cover with three capillary holes, one boiling point tube hole, and one thermometer hole\nIncludes special oil immersion heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStirrer Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControllable with front knob\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapillary Glass Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12mm long, 0.8 to 1.1mm internal diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFine powder properly dried at a temperature considerably below its melting point, 4 to 6 mm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e235 × 285 × 160mm (L×B×H) (Approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 ± 10% VAC, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 Kg. (Approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOn\/Off switch with pilot lamp\nHeating rate adjustment\nHigh\/Low range temperature selector\nStirrer speed control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObservation System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnifier with glare-free background illuminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 9001:2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIncluded Accessories Melting Point Apparatus 931\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003eBox of Capillaries\u003c\/li\u003e\n \t\u003cli\u003eBoiling Point Tubes - 2 Nos.\u003c\/li\u003e\n \t\u003cli\u003eThermometer with range 0-360°C\u003c\/li\u003e\n \t\u003cli\u003eMagnetic Capsule\u003c\/li\u003e\n \t\u003cli\u003eBottle of Silicon Oil\u003c\/li\u003e\n \t\u003cli\u003eGlass Cylindrical Beaker with Teflon cover fitted with immersion heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Design \u0026amp; Operation\u003c\/h3\u003e\n\u003ch4\u003ePrecision Testing Methodology Melting Point Apparatus 931\u003c\/h4\u003e\nThe Melting Point Apparatus Model 931 employs a sophisticated oil bath system for accurate melting point determination:\n\u003col\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSample Preparation\u003c\/strong\u003e - Solid sample is finely powdered and dried at a temperature well below its melting point\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCapillary Loading\u003c\/strong\u003e - A 4-6mm column of sample is loaded into glass capillary tubes\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBath Preparation\u003c\/strong\u003e - The silicon oil bath is filled and the magnetic stirrer activated for uniform temperature distribution\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCapillary Placement\u003c\/strong\u003e - Sample-filled capillaries are inserted into the designated holes in the Teflon cover\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTemperature Control\u003c\/strong\u003e - The heating rate is adjusted using the control knob, with appropriate High\/Low range selection\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSample Observation\u003c\/strong\u003e - The sample is viewed through the magnifier with glare-free illumination to monitor phase changes\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTemperature Monitoring\u003c\/strong\u003e - The included 0-360°C thermometer provides accurate reading of the current temperature\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMelting Point Determination\u003c\/strong\u003e - The temperature at which the sample begins to melt and completely melts is recorded\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003eSilicon Oil Bath Technology Melting Point Apparatus 931\u003c\/h4\u003e\nThe core of the Melting Point Apparatus Model 931 is its sophisticated oil bath heating system:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUniform Heat Distribution\u003c\/strong\u003e - The 200ml silicon oil bath provides consistent temperature throughout the testing environment\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eIntegrated Magnetic Stirring\u003c\/strong\u003e - Continuous stirring eliminates temperature gradients within the oil bath\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSpecialized Immersion Heater\u003c\/strong\u003e - Custom-designed heater ensures optimal heat transfer to the oil\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePrecise Temperature Control\u003c\/strong\u003e - Adjustable heating rate allows for optimal melting point observation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTeflon Cover Design\u003c\/strong\u003e - Strategic placement of openings allows proper alignment of capillaries for observation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMulti-Sample Capability\u003c\/strong\u003e - Three capillary positions enable testing of multiple samples or replicates simultaneously\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnhanced Visibility SystemMelting Point Apparatus 931\u003c\/h4\u003e\nAccurate melting point determination depends on clear observation of physical changes in the sample:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePrecision Magnifier\u003c\/strong\u003e - Provides enlarged view of sample capillaries for detailed observation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eGlare-Free Illumination\u003c\/strong\u003e - Background illuminator ensures optimal visibility of sample phase transitions\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStain-Free Observation\u003c\/strong\u003e - Optical design minimizes eye fatigue during extended use\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eClear Sample Positioning\u003c\/strong\u003e - Optimal arrangement of capillaries in relation to viewing system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003ch4\u003ePharmaceutical Laboratory Applications Melting Point Apparatus 931\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRaw Material Verification\u003c\/strong\u003e - Confirm identity and purity of pharmaceutical ingredients\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuality Control Testing\u003c\/strong\u003e - Ensure batch-to-batch consistency of manufactured compounds\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePharmacopoeia Compliance\u003c\/strong\u003e - Meet USP, EP, JP, and other standards for melting point determination\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStability Testing\u003c\/strong\u003e - Monitor physical property changes during stability studies\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePolymorph Identification\u003c\/strong\u003e - Differentiate between various crystalline forms of the same compound\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFormulation Development\u003c\/strong\u003e - Characterize physical properties of potential excipients and active ingredients\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eChemical Research \u0026amp; Analysis Melting Point Apparatus 931\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompound Identification\u003c\/strong\u003e - Characterize synthesized or isolated organic compounds\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePurity Assessment\u003c\/strong\u003e - Evaluate sample purity through melting range analysis\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEutectic Mixture Analysis\u003c\/strong\u003e - Study binary component interactions through melting behavior\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOrganic Synthesis Verification\u003c\/strong\u003e - Confirm successful synthesis through melting point comparison\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eChemical Quality Verification\u003c\/strong\u003e - Validate specifications of purchased or produced chemicals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEducational Laboratory Use Melting Point Apparatus 931\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePhysical Chemistry Instruction\u003c\/strong\u003e - Demonstrate phase transition principles to students\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOrganic Chemistry Laboratories\u003c\/strong\u003e - Support compound identification and purity assessment\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAnalytical Method Training\u003c\/strong\u003e - Teach fundamental analytical techniques to students\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eResearch Project Support\u003c\/strong\u003e - Provide reliable equipment for undergraduate and graduate research\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePhysical Property Exploration\u003c\/strong\u003e - Facilitate hands-on learning about crystalline material properties\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAdditional Testing Applications Melting Point Apparatus 931\u003c\/h4\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBoiling Point Determination\u003c\/strong\u003e - Measure boiling points of liquid samples using dedicated position\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWax and Polymer Testing\u003c\/strong\u003e - Analyze melting characteristics of industrial materials\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFood Science Applications\u003c\/strong\u003e - Study melting behavior of fats, lipids, and crystalline food components\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eConsumer Product Testing\u003c\/strong\u003e - Evaluate melting properties of ingredients in cosmetics and personal care products\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Advantages for Laboratory Use\u003c\/h3\u003e\n\u003ch4\u003eTesting Accuracy \u0026amp; Reliability Melting Point Apparatus 931\u003c\/h4\u003e\nThe Melting Point Apparatus Model 931 delivers dependable measurement quality through several key design features:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eUniform Heat Distribution\u003c\/strong\u003e - Magnetic stirring eliminates temperature gradients for consistent readings\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePrecision Temperature Control\u003c\/strong\u003e - Adjustable heating rate allows optimization for different sample types\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh-Quality Thermometer\u003c\/strong\u003e - Included 0-360°C thermometer ensures accurate temperature measurement\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDual Range Selection\u003c\/strong\u003e - High\/Low range temperature selector optimizes heating control across the full range\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEnhanced Visibility\u003c\/strong\u003e - Magnifier and glare-free illumination for precise observation of phase changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePractical Laboratory Design Melting Point Apparatus 931\u003c\/h4\u003e\nEngineered for everyday laboratory use with practical considerations:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCompact Footprint\u003c\/strong\u003e - Space-efficient design (235 × 285 × 160mm) for crowded laboratory benches\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLightweight Construction\u003c\/strong\u003e - Approximately 8.7kg for easy positioning and transport\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMulti-Sample Capability\u003c\/strong\u003e - Three capillary positions increase testing throughput\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eComprehensive Accessory Package\u003c\/strong\u003e - All necessary components included for immediate use\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSimple Maintenance\u003c\/strong\u003e - Straightforward cleaning and care requirements\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDurable Construction\u003c\/strong\u003e - Built for continuous laboratory operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eUser-Friendly Operation Melting Point Apparatus 931\u003c\/h4\u003e\nDesigned for straightforward use in busy laboratory environments:\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eIntuitive Controls\u003c\/strong\u003e - Simple On\/Off operation with clear pilot lamp\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eVisual Temperature Monitoring\u003c\/strong\u003e - Easy-to-read thermometer with broad range\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAdjustable Stirring Speed\u003c\/strong\u003e - Front knob control for easy adjustment\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eClear Sample Visibility\u003c\/strong\u003e - Optimized viewing system for comfortable observation\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eBoiling Point Capability\u003c\/strong\u003e - Versatile design accommodates both solid and liquid sample testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperating Instructions Melting Point Apparatus 931\u003c\/h3\u003e\n\u003col\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eInstrument Setup\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003ePlace the apparatus on a flat, stable surface\u003c\/li\u003e\n \t\u003cli\u003eFill the bath with silicon oil to the appropriate level (approximately 200ml)\u003c\/li\u003e\n \t\u003cli\u003eInsert the included thermometer into the designated hole in the Teflon cover\u003c\/li\u003e\n \t\u003cli\u003eConnect to power supply (230V ±10% VAC, 50Hz)\u003c\/li\u003e\n \t\u003cli\u003eTurn on the instrument using the On\/Off switch (pilot lamp will illuminate)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSample Preparation\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eGrind the solid sample into a fine powder\u003c\/li\u003e\n \t\u003cli\u003eEnsure sample is completely dry (pre-dry if necessary at temperature well below melting point)\u003c\/li\u003e\n \t\u003cli\u003ePack capillary tube by gently tapping open end into the powdered sample\u003c\/li\u003e\n \t\u003cli\u003eEnsure sample column height is 4-6mm at bottom of capillary\u003c\/li\u003e\n \t\u003cli\u003eTap capillary on hard surface to compact the sample at the closed end\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTesting Procedure\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eInsert loaded capillaries into designated holes in the Teflon cover\u003c\/li\u003e\n \t\u003cli\u003eSet the High\/Low range temperature selector switch as appropriate\u003c\/li\u003e\n \t\u003cli\u003eAdjust the heating rate using the control indicator\u003c\/li\u003e\n \t\u003cli\u003eActivate the magnetic stirrer and adjust speed with the front knob\u003c\/li\u003e\n \t\u003cli\u003eMonitor the thermometer as temperature rises\u003c\/li\u003e\n \t\u003cli\u003eObserve the sample through the magnifier with illumination\u003c\/li\u003e\n \t\u003cli\u003eRecord the temperature at which the sample begins to melt (initial melting point)\u003c\/li\u003e\n \t\u003cli\u003eNote the temperature at which melting is complete (final melting point)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSystem Cooling\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eTurn off heating after testing is complete\u003c\/li\u003e\n \t\u003cli\u003eAllow the oil bath to cool before removing samples or changing capillaries\u003c\/li\u003e\n \t\u003cli\u003eTurn off the instrument when testing is complete\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFor Boiling Point Determination\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003ePlace liquid sample in the provided boiling point tube\u003c\/li\u003e\n \t\u003cli\u003eInsert tube into the dedicated position in the Teflon cover\u003c\/li\u003e\n \t\u003cli\u003eFollow similar heating procedure as for melting point\u003c\/li\u003e\n \t\u003cli\u003eRecord temperature at which continuous bubbling begins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMaintenance \u0026amp; Care Melting Point Apparatus 931\u003c\/h3\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOil Bath Maintenance\u003c\/strong\u003e - Replace silicon oil periodically or when discolored\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eIlluminator Care\u003c\/strong\u003e - Keep the background illuminator clean for optimal visibility\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMagnifier Cleaning\u003c\/strong\u003e - Clean with appropriate lens cleaning solution as needed\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCapillary Management\u003c\/strong\u003e - Dispose of used capillaries properly; never reuse\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eThermometer Verification\u003c\/strong\u003e - Periodically check accuracy with reference standards\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStirrer Care\u003c\/strong\u003e - Ensure magnetic capsule is clean and rotates freely\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eSurface Cleaning\u003c\/strong\u003e - Wipe external surfaces with slightly damp cloth; avoid harsh solvents\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eStorage\u003c\/strong\u003e - Cover when not in use to protect from dust and damage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAbout Electronics India Melting Point Apparatus 931\u003c\/h3\u003e\nElectronics India is an ISO 9001:2000 certified manufacturer of precision laboratory and analytical equipment. With a comprehensive product range that includes spectrophotometers, analyzers, meters, and testing apparatus, the company has established a reputation for delivering reliable, high-quality instruments for pharmaceutical, research, educational, and industrial applications.\n\nTheir commitment to quality is demonstrated through ISO certification and comprehensive warranty coverage. Electronics India continues to develop innovative solutions for analytical testing needs across various sectors, combining precision technology with practical laboratory functionality.\n\u003ch3\u003eAdditional Products in the Electronics India Range Melting Point Apparatus 931\u003c\/h3\u003e\nElectronics India offers a complete line of analytical and testing equipment including:\n\u003cul\u003e\n \t\u003cli\u003eUV\/VIS Spectrophotometers (Single and Double Beam)\u003c\/li\u003e\n \t\u003cli\u003eSemi-Auto Analyzers\u003c\/li\u003e\n \t\u003cli\u003eFlame Photometers and Hemoglobin Meters\u003c\/li\u003e\n \t\u003cli\u003eDigital pH Meters and Photo Fluorometers\u003c\/li\u003e\n \t\u003cli\u003eDigital Conductivity, TDS, and DO Meters\u003c\/li\u003e\n \t\u003cli\u003eDigital Photo Colorimeters and Turbidity Meters\u003c\/li\u003e\n \t\u003cli\u003eAuto KF Titrimeters and Digital Colony Counters\u003c\/li\u003e\n \t\u003cli\u003eDigital Tablet Disintegration Apparatus\u003c\/li\u003e\n \t\u003cli\u003eDigital Friability Test Apparatus\u003c\/li\u003e\n \t\u003cli\u003eTablet Dissolution Test Apparatus\u003c\/li\u003e\n \t\u003cli\u003eTemperature Indicators and Digital Telethermometers\u003c\/li\u003e\n \t\u003cli\u003eWater \u0026amp; Soil Analysis Kits\u003c\/li\u003e\n \t\u003cli\u003ePortable Testing Equipment\u003c\/li\u003e\n \t\u003cli\u003eVarious Microscopes (Student, Binocular, Medical, Co-Axial)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ: Melting Point Apparatus Model 931\u003c\/h3\u003e\n\u003ch4\u003eWhy is a silicon oil bath used for melting point determination? Melting Point Apparatus 931\u003c\/h4\u003e\nSilicon oil provides several advantages for melting point determination: it offers excellent heat capacity and distribution properties, maintains uniform temperature throughout the bath (especially with magnetic stirring), allows clear visibility of samples, has a high boiling point suitable for the full temperature range (0-300°C), and provides stable, controlled heating characteristics essential for precise melting point measurement.\n\u003ch4\u003eHow does the magnetic stirrer improve measurement accuracy? Melting Point Apparatus 931\u003c\/h4\u003e\nThe integrated magnetic stirrer ensures uniform temperature distribution throughout the oil bath by preventing temperature stratification (layering). Without stirring, temperature gradients could develop where the oil near the heating element becomes hotter than oil at the sample position, leading to inaccurate readings. Constant stirring maintains consistent temperature throughout the bath for more reliable measurements.\n\u003ch4\u003eWhat is the purpose of the High\/Low range temperature selector? Melting Point Apparatus 931\u003c\/h4\u003e\nThe High\/Low range selector optimizes the heating control characteristics for different temperature ranges. For lower melting point samples, the Low range selection provides more precise control and finer temperature adjustment in the lower temperature ranges. For higher melting point samples, the High range selection is optimized for the upper temperature spectrum, ensuring accurate readings throughout the full 0-300°C range.\n\u003ch4\u003eCan I test both melting points and boiling points with this apparatus? Melting Point Apparatus 931\u003c\/h4\u003e\nYes, the Melting Point Apparatus Model 931 is designed to measure both. The Teflon cover has specific positions for three capillary tubes (for solid sample melting points) and one dedicated position for a boiling point tube (for liquid sample boiling points). The included accessories package contains both standard capillaries and specialized boiling point tubes for this purpose.\n\u003ch4\u003eHow many samples can be tested simultaneously?\u003c\/h4\u003e\nThe apparatus can test up to three solid samples simultaneously using the three capillary positions in the Teflon cover. This allows for testing multiple samples in parallel or running replicates of the same sample for verification, increasing laboratory efficiency and testing throughput.\n\u003ch3\u003eSummary Melting Point Apparatus 931\u003c\/h3\u003e\nThe Melting Point Apparatus Model 931 by Electronics India represents a practical and reliable solution for laboratories requiring accurate melting point determination. This ISO 9001:2000 certified instrument combines essential features for precise testing with a user-friendly design suitable for pharmaceutical laboratories, chemical analysis facilities, and educational institutions.\n\nKey advantages include the silicon oil bath with integrated magnetic stirrer for uniform heating, multi-position sample testing capability, enhanced visibility through magnifier and glare-free illumination, and versatile temperature range (0-300°C). The included high-quality accessories, such as the 0-360°C thermometer, capillaries, boiling point tubes, and magnetic capsule, ensure the apparatus is ready for immediate use upon delivery.\n\nWith its compact footprint (235 × 285 × 160mm), lightweight design (8.7 kg), and practical feature set, the Melting Point Apparatus Model 931 offers excellent laboratory value while maintaining the precision and reliability required for critical testing applications. The ability to test both melting points of solid samples and boiling points of liquid samples enhances its versatility as a laboratory instrument.\n\nBacked by Electronics India's reputation for quality instrumentation and protected by a 1-year warranty, the Melting Point Apparatus Model 931 delivers professional-grade performance for melting point analysis across a wide range of solid samples, making it an essential tool for any quality-focused laboratory requiring reliable physical property testing.","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51460965499126,"sku":"EI-MEL-931","price":38350.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Melting_Point_Apparatus_931__81698.1754463759.386.513_7fea31fe-9c86-4e7d-8cb5-f8b53c8eb10d.jpg?v=1786598909"},{"product_id":"digital-melting-point-apparatus-model-2935-high-resolution-tft-camera-for-pharmaceutical-and-lab-use","title":"Digital Melting Point Apparatus Model 2935: High-Resolution TFT Camera for Pharmaceutical and Lab Use","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e\n:root {\n    --primary-blue: #004a99;\n    --hover-blue: #0056b3;\n    --bg-gray: #f8f9fa;\n    --text-color: #333;\n    --border-color: #ddd;\n    --white: #ffffff;\n}\nbody {font-family:'Segoe UI',Tahoma,Geneva,Verdana,sans-serif;line-height:1.6;color:var(--text-color);background-color:var(--bg-gray);margin:0;padding:20px;}\n.scispectrum-tabs-container {max-width:1200px;margin:0 auto;background:var(--white);border-radius:8px;box-shadow:0 4px 15px rgba(0,0,0,0.05);overflow:hidden;}\n.tab-input {display:none;}\n.tab-nav {display:flex;flex-wrap:wrap;border-bottom:2px solid var(--border-color);}\n.tab-label {padding:15px 25px;cursor:pointer;font-weight:600;color:var(--primary-blue);flex-grow:1;text-align:center;}\n.tab-label:hover {background-color:rgba(0,74,153,0.05);}\n#tab1:checked ~ .tab-nav label[for=\"tab1\"],\n#tab2:checked ~ .tab-nav label[for=\"tab2\"],\n#tab3:checked ~ .tab-nav label[for=\"tab3\"],\n#tab4:checked ~ .tab-nav label[for=\"tab4\"] {border-bottom:3px solid var(--primary-blue);}\n.tab-panels {padding:30px;}\n.tab-content {display:none;}\n#tab1:checked ~ .tab-panels #content1,\n#tab2:checked ~ .tab-panels #content2,\n#tab3:checked ~ .tab-panels #content3,\n#tab4:checked ~ .tab-panels #content4 {display:block;}\nh3 {color:var(--primary-blue);}\n.spec-table {width:100%;border-collapse:collapse;margin-top:20px;}\n.spec-table th,.spec-table td {padding:12px;border-bottom:1px solid var(--border-color);}\n.spec-table th {background:var(--primary-blue);color:white;}\n.features-list {list-style:none;padding:0;display:grid;grid-template-columns:repeat(auto-fit,minmax(280px,1fr));gap:20px;}\n.features-list li {background:white;padding:20px;border:1px solid var(--border-color);border-radius:6px;padding-left:45px;position:relative;}\n.features-list li::before {content:'✓';position:absolute;left:15px;color:var(--primary-blue);font-weight:bold;}\n.feature-title {font-weight:700;color:var(--primary-blue);}\n.faq-item {margin-bottom:20px;border-bottom:1px solid var(--border-color);}\n.faq-question {font-weight:600;color:var(--primary-blue);}\n\u003c\/style\u003e\n\u003cdiv class=\"scispectrum-tabs-container\"\u003e\n\u003cinput id=\"tab1\" class=\"tab-input\" checked name=\"tabs\" type=\"radio\"\u003e \u003cinput id=\"tab2\" class=\"tab-input\" name=\"tabs\" type=\"radio\"\u003e \u003cinput id=\"tab3\" class=\"tab-input\" name=\"tabs\" type=\"radio\"\u003e \u003cinput id=\"tab4\" class=\"tab-input\" name=\"tabs\" type=\"radio\"\u003e\u003cnav class=\"tab-nav\"\u003e\u003clabel class=\"tab-label\" for=\"tab1\"\u003eOverview\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab2\"\u003eSpecifications\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab3\"\u003eFeatures \u0026amp; Benefits\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab4\"\u003eFAQs\u003c\/label\u003e\u003c\/nav\u003e\n\u003cdiv class=\"tab-panels\"\u003e\n\u003c!-- OVERVIEW --\u003e\n\u003cdiv id=\"content1\" class=\"tab-content\"\u003e\n\u003ch3\u003eDigital Melting Point Apparatus Model 2935\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDigital Melting Point Apparatus Model 2935\u003c\/strong\u003e is a precision laboratory instrument designed for accurate melting point determination and purity analysis of solid compounds. Widely used in pharmaceutical, chemical, and research laboratories, it ensures reliable identification of substances through sharp melting range observation.\u003c\/p\u003e\n\u003cp\u003eEquipped with a \u003cstrong\u003ehigh-resolution TFT camera system\u003c\/strong\u003e and integrated viewing display, the instrument enables clear visual monitoring of sample melting behavior. Its digital temperature measurement with \u003cstrong\u003e0.1°C resolution\u003c\/strong\u003e ensures precise and repeatable results.\u003c\/p\u003e\n\u003cp\u003eThe apparatus features a \u003cstrong\u003euniform silicon oil bath heating system\u003c\/strong\u003e with built-in magnetic stirring, providing consistent temperature distribution. Combined with PT-100 sensor accuracy and intuitive controls, Model 2935 delivers dependable performance for quality control, research, and analytical testing environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003cdiv id=\"content2\" class=\"tab-content\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-digit LED + TFT screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViewing System\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution camera + magnifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating System\u003c\/td\u003e\n\u003ctd\u003eSilicon oil bath with immersion heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003ePT-100 RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Capacity\u003c\/td\u003e\n\u003ctd\u003e3 capillary tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil Bath Capacity\u003c\/td\u003e\n\u003ctd\u003e~200 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System\u003c\/td\u003e\n\u003ctd\u003eElectronic heating control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd\u003eStart\/Stop\/Clear switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- FEATURES --\u003e\n\u003cdiv id=\"content3\" class=\"tab-content\"\u003e\n\u003ch3\u003eCore Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul class=\"features-list\"\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eHigh Accuracy Measurement\u003c\/span\u003eEnsures precise melting point determination with 0.1°C resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eIntegrated Camera System\u003c\/span\u003eProvides clear real-time visualization of melting process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eUniform Heating Control\u003c\/span\u003eOil bath with magnetic stirring ensures stable temperature distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eUser-Friendly Operation\u003c\/span\u003eSimple controls with Start\/Stop functions for easy testing workflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eEnhanced Observation\u003c\/span\u003eMagnifier and glare-free illumination improve sample visibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eReliable Laboratory Performance\u003c\/span\u003eIdeal for pharma QC, chemical labs, and research applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv id=\"content4\" class=\"tab-content\"\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat is a melting point apparatus used for?\u003c\/p\u003e\n\u003cp\u003eA melting point apparatus is used to determine the temperature at which a solid substance melts. It helps identify compounds and assess purity by measuring the melting range, which is critical in pharmaceutical, chemical, and research laboratories.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eHow accurate is the Model 2935 melting point apparatus?\u003c\/p\u003e\n\u003cp\u003eThe Model 2935 provides high accuracy with a temperature resolution of 0.1°C. Combined with a PT-100 sensor and controlled oil bath heating, it ensures precise and repeatable melting point measurements for laboratory applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat is the advantage of a TFT camera system?\u003c\/p\u003e\n\u003cp\u003eThe integrated TFT camera allows real-time visual monitoring of the melting process. This improves observation accuracy and reduces human error compared to traditional manual viewing methods.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhy is oil bath heating used in melting point apparatus?\u003c\/p\u003e\n\u003cp\u003eOil bath heating ensures uniform and stable temperature distribution around the sample. This prevents temperature fluctuations and allows accurate detection of melting onset and completion.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhere is this apparatus commonly used?\u003c\/p\u003e\n\u003cp\u003eThe Digital Melting Point Apparatus is widely used in pharmaceutical industries, chemical laboratories, and research institutions for purity testing, compound identification, and quality control analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51460975165686,"sku":"EI-MEL-2935","price":89562.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Digital_Melting_Point_Apparatus_MODEL_-_2935__44599.1759838943.386.513.jpg?v=1786599174"},{"product_id":"high-resolution-digital-melting-point-apparatus-3935-visual-microcontroller-control","title":"High-Resolution Digital Melting Point Apparatus 3935 | Visual \u0026 Microcontroller Control","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e\n    :root {\n        --primary-blue: #004a99;\n        --hover-blue: #0056b3;\n        --bg-gray: #f8f9fa;\n        --text-color: #333;\n        --border-color: #ddd;\n        --white: #ffffff;\n    }\n\n    body {\n        font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif;\n        line-height: 1.6;\n        color: var(--text-color);\n        background-color: var(--bg-gray);\n        margin: 0;\n        padding: 20px;\n    }\n\n    .scispectrum-tabs-container {\n        max-width: 1200px;\n        margin: 0 auto;\n        background: var(--white);\n        border-radius: 8px;\n        box-shadow: 0 4px 15px rgba(0,0,0,0.05);\n        overflow: hidden;\n    }\n\n    .tab-input {\n        display: none;\n    }\n\n    .tab-nav {\n        display: flex;\n        flex-wrap: wrap;\n        border-bottom: 2px solid var(--border-color);\n        background-color: var(--white);\n    }\n\n    .tab-label {\n        padding: 15px 25px;\n        cursor: pointer;\n        font-weight: 600;\n        color: var(--primary-blue);\n        transition: all 0.3s ease;\n        border-bottom: 3px solid transparent;\n        text-align: center;\n        flex-grow: 1;\n    }\n\n    .tab-label:hover {\n        background-color: rgba(0, 74, 153, 0.05);\n        color: var(--hover-blue);\n    }\n\n    #tab1:checked ~ .tab-nav label[for=\"tab1\"],\n    #tab2:checked ~ .tab-nav label[for=\"tab2\"],\n    #tab3:checked ~ .tab-nav label[for=\"tab3\"],\n    #tab4:checked ~ .tab-nav label[for=\"tab4\"] {\n        border-bottom-color: var(--primary-blue);\n        color: var(--primary-blue);\n        background-color: var(--white);\n    }\n\n    .tab-panels {\n        padding: 30px;\n    }\n\n    .tab-content {\n        display: none;\n        animation: fadeIn 0.5s ease;\n    }\n\n    #tab1:checked ~ .tab-panels #content1,\n    #tab2:checked ~ .tab-panels #content2,\n    #tab3:checked ~ .tab-panels #content3,\n    #tab4:checked ~ .tab-panels #content4 {\n        display: block;\n    }\n\n    @keyframes fadeIn {\n        from { opacity: 0; }\n        to { opacity: 1; }\n    }\n\n    h3 {\n        color: var(--primary-blue);\n        margin-top: 0;\n    }\n\n    .spec-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin-top: 20px;\n        font-size: 0.95rem;\n    }\n\n    .spec-table th,\n    .spec-table td {\n        text-align: left;\n        padding: 12px 15px;\n        border-bottom: 1px solid var(--border-color);\n    }\n\n    .spec-table th {\n        background-color: var(--primary-blue);\n        color: var(--white);\n        text-transform: uppercase;\n        letter-spacing: 0.05em;\n    }\n\n    .spec-table tr:nth-child(even) {\n        background-color: rgba(0, 74, 153, 0.02);\n    }\n\n    .spec-table tr:hover {\n        background-color: rgba(0, 74, 153, 0.05);\n    }\n\n    .features-list {\n        list-style: none;\n        padding: 0;\n        display: grid;\n        grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n        gap: 20px;\n    }\n\n    .features-list li {\n        background: var(--white);\n        padding: 20px;\n        border-radius: 6px;\n        border: 1px solid var(--border-color);\n        position: relative;\n        padding-left: 50px;\n        transition: transform 0.2s ease;\n    }\n\n    .features-list li:hover {\n        transform: translateY(-3px);\n        box-shadow: 0 2px 10px rgba(0,0,0,0.05);\n    }\n\n    .features-list li::before {\n        content: '✓';\n        position: absolute;\n        left: 15px;\n        top: 20px;\n        color: var(--primary-blue);\n        font-weight: bold;\n        font-size: 1.2rem;\n    }\n\n    .feature-title {\n        font-weight: 700;\n        color: var(--primary-blue);\n        display: block;\n        margin-bottom: 5px;\n    }\n\n    .faq-item {\n        margin-bottom: 25px;\n        border-bottom: 1px solid var(--border-color);\n        padding-bottom: 15px;\n    }\n\n    .faq-question {\n        font-weight: 600;\n        color: var(--primary-blue);\n        margin-bottom: 10px;\n        font-size: 1.1rem;\n    }\n\n    @media (max-width: 768px) {\n        html, body {\n            padding: 0 !important;\n            margin: 0 !important;\n            width: 100%;\n            overflow-x: hidden;\n        }\n\n        .scispectrum-tabs-container {\n            width: 100% !important;\n            max-width: 100% !important;\n            margin: 0 !important;\n            border-radius: 0 !important;\n            box-shadow: none;\n        }\n\n        .tab-panels {\n            padding: 15px 8px !important;\n        }\n\n        .tab-label {\n            flex: 1 0 48%;\n            font-size: 0.85rem;\n            padding: 12px 2px;\n            box-sizing: border-box;\n        }\n\n        .faq-item {\n            margin: 0 0 15px 0 !important;\n            padding: 12px !important;\n            width: 100%;\n            box-sizing: border-box;\n        }\n    }\n\u003c\/style\u003e\n\u003cdiv class=\"scispectrum-tabs-container\"\u003e\n\u003cinput id=\"tab1\" class=\"tab-input\" checked name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab2\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab3\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab4\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e\u003cnav class=\"tab-nav\"\u003e\u003clabel class=\"tab-label\" for=\"tab1\"\u003eOverview\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab2\"\u003eSpecifications\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab3\"\u003eFeatures \u0026amp; Benefits\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab4\"\u003eFAQs \u0026amp; Schema\u003c\/label\u003e\u003c\/nav\u003e\n\u003cdiv class=\"tab-panels\"\u003e\n\u003cdiv id=\"content1\" class=\"tab-content\"\u003e\n\u003ch3\u003eHigh-Resolution Digital Melting Point Apparatus Model 3935 – Microcontroller Visual Melting Point Analysis System\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDigital Melting Point Apparatus Model 3935\u003c\/strong\u003e is a highly advanced microcontroller-based visual melting point determination system engineered for precise analysis of melting points and melting ranges of crystalline and solid samples. Designed for pharmaceutical laboratories, chemical research facilities, academic institutions, and industrial quality control environments, this high-resolution melting point apparatus combines intelligent temperature programming, automated visual monitoring, and superior analytical accuracy for reliable thermal characterization.\u003c\/p\u003e\n\u003cp\u003eThe Model 3935 features an integrated high-resolution camera with a bright 7-inch TFT graphical display, enabling real-time visual observation of sample phase transitions during testing. This advanced visual monitoring capability significantly improves operator accuracy while simplifying melting point determination procedures in demanding laboratory applications.\u003c\/p\u003e\n\u003cp\u003eFor highly stable and reproducible thermal performance, the apparatus utilizes a precision silicon oil-bath heating system with immersion heater technology and an integrated magnetic stirrer for uniform heat distribution. The programmable plateau temperature and adjustable ramp heating control allow rapid preheating followed by precise slow heating near the expected melting point, minimizing overshoot and improving analytical precision.\u003c\/p\u003e\n\u003cp\u003eThe instrument incorporates advanced pharmaceutical compliance functionality including 3-tier password protection, storage of up to 300 test results, multiple programmable setup configurations, RS232 serial printing capability, and calibration features supporting pharma compliance and 21CFR-oriented workflows.\u003c\/p\u003e\n\u003cp\u003eWidely used for pharmaceutical quality assurance, raw material verification, purity testing, organic compound identification, research applications, and advanced thermal analysis, the Model 3935 Visual Melting Point Apparatus delivers exceptional laboratory performance, digital precision, and user-friendly operation for modern analytical environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content2\" class=\"tab-content\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3935\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstrument Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicrocontroller Visual Melting Point Apparatus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient to 300°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePT100 Platinum Resistance Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\" Graphical LCD Display \/ Colored TFT Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObservation System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated High-Resolution Camera\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImmersion Heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Medium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSilicon Oil-Bath with Teflon Cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStirrer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Magnetic Stirrer with Adjustable Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRamp Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Scale 1 – 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapillary Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Capillary Tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Results + 100 Setup Data Configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Security\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Tier Password Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 Serial Printing Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports Pharma Compliance \u0026amp; 21CFR-Oriented Validation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V ±10% AC, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × B × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e375 × 300 × 330 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content3\" class=\"tab-content\"\u003e\n\u003ch3\u003eCore Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul class=\"features-list\"\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eVisual Monitoring with High-Resolution Camera\u003c\/span\u003e Provides clear real-time observation of sample melting behavior for enhanced analytical confidence and improved result accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eHighly Accurate Temperature Measurement\u003c\/span\u003e 0.1°C digital resolution with PT100 sensor ensures dependable and reproducible melting point analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eUniform Oil-Bath Heating System\u003c\/span\u003e Integrated magnetic stirring maintains consistent heat distribution throughout the silicon oil bath for precise thermal analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eProgrammable Plateau \u0026amp; Ramp Heating\u003c\/span\u003e Advanced programmable temperature control minimizes overheating and improves melting point determination accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eLarge TFT Graphical Display\u003c\/span\u003e Bright 7-inch display enables easy visual monitoring and simplified operation in laboratory environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003e300 Result Memory Storage\u003c\/span\u003e Stores large volumes of analytical results and setup configurations for traceability and workflow efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003ePharma Compliance Ready\u003c\/span\u003e Supports 3-tier password security, calibration functionality, and validation workflows suitable for regulated laboratories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eRapid Melt Method Support\u003c\/span\u003e Facilitates efficient analysis of unknown samples and new compounds using rapid melt evaluation procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eIntegrated RS232 Printing Interface\u003c\/span\u003e Allows online and offline printing of analytical results with date and time documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content4\" class=\"tab-content\"\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat is the primary application of the Digital Melting Point Apparatus Model 3935?\u003c\/p\u003e\n\u003cp\u003eThe Model 3935 is designed for highly accurate melting point determination and melting range analysis of crystalline and solid samples in pharmaceutical, chemical, and research laboratories.\u003c\/p\u003e\n\u003cp\u003eIt is commonly used for purity testing, raw material verification, compound identification, and advanced quality control applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eHow does the visual monitoring system improve melting point analysis?\u003c\/p\u003e\n\u003cp\u003eThe integrated high-resolution camera and TFT display provide real-time visual observation of sample phase transitions during heating.\u003c\/p\u003e\n\u003cp\u003eThis visual confirmation improves operator accuracy and minimizes interpretation errors during melting point determination.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhy is programmable ramp heating important in melting point testing?\u003c\/p\u003e\n\u003cp\u003eProgrammable ramp heating allows rapid preheating followed by slow controlled heating near the expected melting point for greater analytical precision.\u003c\/p\u003e\n\u003cp\u003eThis reduces temperature overshoot and improves repeatability of melting point measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eDoes the Model 3935 support pharmaceutical compliance requirements?\u003c\/p\u003e\n\u003cp\u003eYes, the apparatus includes advanced features such as 3-tier password protection, data storage, calibration functionality, and validation support for pharma-oriented workflows.\u003c\/p\u003e\n\u003cp\u003eThese features help laboratories maintain traceability, accountability, and regulatory compliance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eHow many test results can the apparatus store internally?\u003c\/p\u003e\n\u003cp\u003eThe Model 3935 can store up to 300 analytical results along with 100 programmable setup configurations for efficient laboratory data management.\u003c\/p\u003e\n\u003cp\u003eThe stored information improves workflow continuity and analytical traceability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51460975263990,"sku":"EI-MEL-3935","price":188800.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Digital_Melting_Point_Apparatus_MODEL_-_3935_2__93213.1759841135.386.513.jpg?v=1786599177"},{"product_id":"auto-melting-point-apparatus-1935-ei-dvi-led","title":"Auto Melting Point Apparatus 1935 | 4-Digit LED Display | EI-DVI Precision","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e\n    \/* SciSpectrum Color Scheme \u0026 Basics *\/\n    :root {\n        --primary-blue: #004a99;\n        --hover-blue: #0056b3;\n        --bg-gray: #f8f9fa;\n        --text-color: #333;\n        --border-color: #ddd;\n        --white: #ffffff;\n    }\n\n    body {\n        font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif;\n        line-height: 1.6;\n        color: var(--text-color);\n        background-color: var(--bg-gray);\n        margin: 0;\n        padding: 20px;\n    }\n\n    .scispectrum-tabs-container {\n        max-width: 1200px;\n        margin: 0 auto;\n        background: var(--white);\n        border-radius: 8px;\n        box-shadow: 0 4px 15px rgba(0,0,0,0.05);\n        overflow: hidden;\n    }\n\n    .tab-input {\n        display: none;\n    }\n\n    .tab-nav {\n        display: flex;\n        flex-wrap: wrap;\n        border-bottom: 2px solid var(--border-color);\n        background-color: var(--white);\n    }\n\n    .tab-label {\n        padding: 15px 25px;\n        cursor: pointer;\n        font-weight: 600;\n        color: var(--primary-blue);\n        transition: all 0.3s ease;\n        border-bottom: 3px solid transparent;\n        text-align: center;\n        flex-grow: 1;\n    }\n\n    .tab-label:hover {\n        background-color: rgba(0, 74, 153, 0.05);\n        color: var(--hover-blue);\n    }\n\n    #tab1:checked ~ .tab-nav label[for=\"tab1\"],\n    #tab2:checked ~ .tab-nav label[for=\"tab2\"],\n    #tab3:checked ~ .tab-nav label[for=\"tab3\"],\n    #tab4:checked ~ .tab-nav label[for=\"tab4\"] {\n        border-bottom-color: var(--primary-blue);\n        color: var(--primary-blue);\n        background-color: var(--white);\n    }\n\n    .tab-panels {\n        padding: 30px;\n    }\n\n    .tab-content {\n        display: none;\n        animation: fadeIn 0.5s ease;\n    }\n\n    #tab1:checked ~ .tab-panels #content1,\n    #tab2:checked ~ .tab-panels #content2,\n    #tab3:checked ~ .tab-panels #content3,\n    #tab4:checked ~ .tab-panels #content4 {\n        display: block;\n    }\n\n    @keyframes fadeIn {\n        from { opacity: 0; }\n        to { opacity: 1; }\n    }\n\n    h3 {\n        color: var(--primary-blue);\n        margin-top: 0;\n    }\n\n    .spec-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin-top: 20px;\n        font-size: 0.95rem;\n    }\n\n    .spec-table th,\n    .spec-table td {\n        text-align: left;\n        padding: 12px 15px;\n        border-bottom: 1px solid var(--border-color);\n    }\n\n    .spec-table th {\n        background-color: var(--primary-blue);\n        color: var(--white);\n        text-transform: uppercase;\n        letter-spacing: 0.05em;\n    }\n\n    .spec-table tr:nth-child(even) {\n        background-color: rgba(0, 74, 153, 0.02);\n    }\n\n    .spec-table tr:hover {\n        background-color: rgba(0, 74, 153, 0.05);\n    }\n\n    .features-list {\n        list-style: none;\n        padding: 0;\n        display: grid;\n        grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n        gap: 20px;\n    }\n\n    .features-list li {\n        background: var(--white);\n        padding: 20px;\n        border-radius: 6px;\n        border: 1px solid var(--border-color);\n        position: relative;\n        padding-left: 50px;\n        transition: transform 0.2s ease;\n    }\n\n    .features-list li:hover {\n        transform: translateY(-3px);\n        box-shadow: 0 2px 10px rgba(0,0,0,0.05);\n    }\n\n    .features-list li::before {\n        content: '✓';\n        position: absolute;\n        left: 15px;\n        top: 20px;\n        color: var(--primary-blue);\n        font-weight: bold;\n        font-size: 1.2rem;\n    }\n\n    .feature-title {\n        font-weight: 700;\n        color: var(--primary-blue);\n        display: block;\n        margin-bottom: 5px;\n    }\n\n    .faq-item {\n        margin-bottom: 25px;\n        border-bottom: 1px solid var(--border-color);\n        padding-bottom: 15px;\n    }\n\n    .faq-question {\n        font-weight: 600;\n        color: var(--primary-blue);\n        margin-bottom: 10px;\n        font-size: 1.1rem;\n    }\n\n    @media (max-width: 768px) {\n        html, body {\n            padding: 0 !important;\n            margin: 0 !important;\n            width: 100%;\n            overflow-x: hidden;\n        }\n\n        .scispectrum-tabs-container {\n            width: 100% !important;\n            max-width: 100% !important;\n            margin: 0 !important;\n            border-radius: 0 !important;\n            box-shadow: none;\n        }\n\n        .tab-panels {\n            padding: 15px 8px !important;\n        }\n\n        .tab-label {\n            flex: 1 0 48%;\n            font-size: 0.85rem;\n            padding: 12px 2px;\n            box-sizing: border-box;\n        }\n\n        .faq-item {\n            margin: 0 0 15px 0 !important;\n            padding: 12px !important;\n            width: 100%;\n            box-sizing: border-box;\n        }\n    }\n\u003c\/style\u003e\n\u003cdiv class=\"scispectrum-tabs-container\"\u003e\n\u003cinput id=\"tab1\" class=\"tab-input\" checked name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab2\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab3\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab4\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e\u003cnav class=\"tab-nav\"\u003e\u003clabel class=\"tab-label\" for=\"tab1\"\u003eOverview\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab2\"\u003eSpecifications\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab3\"\u003eFeatures \u0026amp; Benefits\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab4\"\u003eFAQs\u003c\/label\u003e\u003c\/nav\u003e\n\u003cdiv class=\"tab-panels\"\u003e\n\u003cdiv id=\"content1\" class=\"tab-content\"\u003e\n\u003ch3\u003eEI-DVI Auto Melting Point Apparatus Model 1935 – Precision Digital Melting Point Determination System\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEI-DVI Auto Melting Point Apparatus Model 1935\u003c\/strong\u003e is a precision-engineered laboratory instrument designed for accurate determination of melting point temperatures of crystalline substances using capillary tube analysis. Developed with advanced microcontroller technology and intelligent temperature programming, this high-performance melting point apparatus delivers enhanced analytical accuracy, reproducibility, and operational convenience for pharmaceutical laboratories, chemical research facilities, educational institutions, and industrial quality control environments.\u003c\/p\u003e\n\u003cp\u003eDesigned for precise thermal analysis applications, the Model 1935 incorporates programmable plateau temperature and controlled ramp heating functionality, enabling rapid initial heating followed by highly controlled slow heating near the expected melting point. This intelligent temperature control significantly improves measurement precision and repeatability during purity analysis and compound identification.\u003c\/p\u003e\n\u003cp\u003eThe instrument features a bright 4-digit seven-segment LED display with integrated operational status indicators including RUN, END, READY, PLATEAU, and RECALL functions for simplified workflow monitoring. The system provides direct digital temperature indication with 0.1°C resolution and utilizes a highly stable Platinum Resistance Pt100 sensor for dependable thermal measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eFor enhanced productivity and laboratory convenience, the apparatus includes memory storage capability for up to 100 melting point results, retained even after power shutdown. The integrated quick cooling fan minimizes waiting time between analyses, while the dedicated cleaning mode allows efficient removal of broken capillary tubes from the heating chamber.\u003c\/p\u003e\n\u003cp\u003eWidely used in pharmaceutical quality control, organic chemistry research, chemical synthesis validation, and academic laboratories, the EI-DVI Model 1935 Auto Melting Point Apparatus offers an ideal combination of precision, programmable control, and reliable laboratory performance for advanced melting point determination applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content2\" class=\"tab-content\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter \/ Feature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto Melting Point Apparatus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1935\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicrocontroller Based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Sample at a Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient to 300°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1°C at 20°C; ±2.5°C at 300°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlatinum Resistance Pt100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Digit Seven Segment LED Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRamp Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Scale 1 – 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlateau Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully Programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyboard Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft Touch Membrane Keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLATEAU, °C, RAMP, RUN, END, READY \u0026amp; RECALL LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStores up to 100 Results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Quick Cooling Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCleaning Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal \/ Clean Rotary Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 × 300 × 350 mm (Approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 9.0 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 230V ±10%, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapillary Box, Operation Manual, Dust Cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePharmaceutical QC, Chemical Analysis, Purity Testing, Academic Research, Organic Compound Identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content3\" class=\"tab-content\"\u003e\n\u003ch3\u003eCore Features \u0026amp; User Benefits\u003c\/h3\u003e\n\u003cp\u003eThe EI-DVI Model 1935 Auto Melting Point Apparatus is engineered to provide accurate thermal analysis, programmable temperature control, and dependable laboratory operation for pharmaceutical and chemical testing applications.\u003c\/p\u003e\n\u003cul class=\"features-list\"\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eAdvanced Microcontroller Technology\u003c\/span\u003e The intelligent microcontroller-based system delivers highly stable temperature control and enhanced analytical reproducibility for precision melting point determination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eProgrammable Plateau \u0026amp; Ramp Heating\u003c\/span\u003e The apparatus allows rapid heating to a predefined plateau temperature followed by controlled slow ramp heating for highly accurate melting point detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eHigh Accuracy Temperature Measurement\u003c\/span\u003e The integrated Pt100 platinum resistance sensor ensures dependable thermal monitoring with precise 0.1°C display resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eBright Digital LED Display\u003c\/span\u003e The 4-digit seven-segment LED display provides clear temperature visibility and operational status monitoring during testing procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eIntegrated Result Memory\u003c\/span\u003e The system stores up to 100 melting point results internally, improving data management and laboratory traceability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eQuick Cooling Function\u003c\/span\u003e An integrated cooling fan accelerates chamber cooling between tests, improving productivity and reducing waiting time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eEasy Cleaning System\u003c\/span\u003e The dedicated Normal\/Clean rotary switch simplifies removal of broken capillary tubes from the heating chamber for easy maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eUser-Friendly Soft Touch Controls\u003c\/span\u003e Soft touch membrane keys provide convenient parameter programming and simplified laboratory operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eIdeal for Pharmaceutical Quality Control\u003c\/span\u003e Widely suitable for purity testing, API verification, chemical characterization, compound identification, and research laboratory applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content4\" class=\"tab-content\"\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat is the primary use of the EI-DVI Auto Melting Point Apparatus Model 1935?\u003c\/p\u003e\n\u003cp\u003eThe EI-DVI Model 1935 is primarily used for accurate determination of melting point temperatures of crystalline compounds and organic substances using capillary tube analysis.\u003c\/p\u003e\n\u003cp\u003eIt is widely utilized in pharmaceutical quality control laboratories, chemical research facilities, academic institutions, and industrial laboratories for purity analysis and compound identification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eHow does the programmable plateau temperature improve measurement accuracy?\u003c\/p\u003e\n\u003cp\u003eThe programmable plateau temperature allows the instrument to rapidly heat close to the expected melting point before automatically switching to a slower controlled heating rate.\u003c\/p\u003e\n\u003cp\u003eThis minimizes temperature overshoot and improves the precision and reproducibility of final melting point measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eDoes the apparatus store previous melting point results?\u003c\/p\u003e\n\u003cp\u003eYes, the Model 1935 includes internal memory storage capability for up to 100 melting point results.\u003c\/p\u003e\n\u003cp\u003eThe stored results remain محفوظ even after the instrument power is switched off, supporting laboratory documentation and traceability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat type of temperature sensor is used in the Model 1935?\u003c\/p\u003e\n\u003cp\u003eThe instrument uses a Platinum Resistance Pt100 temperature sensor for highly stable and accurate temperature monitoring.\u003c\/p\u003e\n\u003cp\u003eThis precision sensor contributes to reliable thermal analysis performance across the full operating range up to 300°C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhich industries commonly use auto melting point apparatus systems?\u003c\/p\u003e\n\u003cp\u003eAuto melting point apparatus systems are commonly used in pharmaceutical manufacturing, chemical processing, research laboratories, educational institutions, and quality control laboratories.\u003c\/p\u003e\n\u003cp\u003eThey are especially important for purity determination, raw material verification, compound characterization, and analytical research applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51461015077110,"sku":"EI-MEL-1935","price":73042.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Auto_Melting_Point_1934_EI-DVI_LED_Display__50636.1759839496.386.513.jpg?v=1786599175"},{"product_id":"electronics-india-model-1934-auto-melting-point-apparatus","title":"Electronics India Auto Melting Point Apparatus 1934 | Digital Laboratory MP Tester","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e \/* SciSpectrum Color Scheme \u0026 Basics *\/ :root { --primary-blue: #004a99; --hover-blue: #0056b3; --bg-gray: #f8f9fa; --text-color: #333; --border-color: #ddd; --white: #ffffff; }\nbody {\n    font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif;\n    line-height: 1.6;\n    color: var(--text-color);\n    background-color: var(--bg-gray);\n    margin: 0;\n    padding: 20px;\n}\n\n.scispectrum-tabs-container {\n    max-width: 1200px;\n    margin: 0 auto;\n    background: var(--white);\n    border-radius: 8px;\n    box-shadow: 0 4px 15px rgba(0,0,0,0.05);\n    overflow: hidden;\n}\n\n.tab-input {\n    display: none;\n}\n\n.tab-nav {\n    display: flex;\n    flex-wrap: wrap;\n    border-bottom: 2px solid var(--border-color);\n    background-color: var(--white);\n}\n\n.tab-label {\n    padding: 15px 25px;\n    cursor: pointer;\n    font-weight: 600;\n    color: var(--primary-blue);\n    transition: all 0.3s ease;\n    border-bottom: 3px solid transparent;\n    text-align: center;\n    flex-grow: 1;\n}\n\n.tab-label:hover {\n    background-color: rgba(0, 74, 153, 0.05);\n    color: var(--hover-blue);\n}\n\n#tab1:checked ~ .tab-nav label[for=\"tab1\"],\n#tab2:checked ~ .tab-nav label[for=\"tab2\"],\n#tab3:checked ~ .tab-nav label[for=\"tab3\"],\n#tab4:checked ~ .tab-nav label[for=\"tab4\"] {\n    border-bottom-color: var(--primary-blue);\n    color: var(--primary-blue);\n    background-color: var(--white);\n}\n\n.tab-panels {\n    padding: 30px;\n}\n\n.tab-content {\n    display: none;\n    animation: fadeIn 0.5s ease;\n}\n\n#tab1:checked ~ .tab-panels #content1,\n#tab2:checked ~ .tab-panels #content2,\n#tab3:checked ~ .tab-panels #content3,\n#tab4:checked ~ .tab-panels #content4 {\n    display: block;\n}\n\n@keyframes fadeIn {\n    from { opacity: 0; }\n    to { opacity: 1; }\n}\n\nh3 {\n    color: var(--primary-blue);\n    margin-top: 0;\n}\n\n.spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin-top: 20px;\n    font-size: 0.95rem;\n}\n\n.spec-table th,\n.spec-table td {\n    text-align: left;\n    padding: 12px 15px;\n    border-bottom: 1px solid var(--border-color);\n}\n\n.spec-table th {\n    background-color: var(--primary-blue);\n    color: var(--white);\n    text-transform: uppercase;\n    letter-spacing: 0.05em;\n}\n\n.spec-table tr:nth-child(even) {\n    background-color: rgba(0, 74, 153, 0.02);\n}\n\n.spec-table tr:hover {\n    background-color: rgba(0, 74, 153, 0.05);\n}\n\n.features-list {\n    list-style: none;\n    padding: 0;\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n    gap: 20px;\n}\n\n.features-list li {\n    background: var(--white);\n    padding: 20px;\n    border-radius: 6px;\n    border: 1px solid var(--border-color);\n    position: relative;\n    padding-left: 50px;\n    transition: transform 0.2s ease;\n}\n\n.features-list li:hover {\n    transform: translateY(-3px);\n    box-shadow: 0 2px 10px rgba(0,0,0,0.05);\n}\n\n.features-list li::before {\n    content: '✓';\n    position: absolute;\n    left: 15px;\n    top: 20px;\n    color: var(--primary-blue);\n    font-weight: bold;\n    font-size: 1.2rem;\n}\n\n.feature-title {\n    font-weight: 700;\n    color: var(--primary-blue);\n    display: block;\n    margin-bottom: 5px;\n}\n\n.faq-item {\n    margin-bottom: 25px;\n    border-bottom: 1px solid var(--border-color);\n    padding-bottom: 15px;\n}\n\n.faq-question {\n    font-weight: 600;\n    color: var(--primary-blue);\n    margin-bottom: 10px;\n    font-size: 1.1rem;\n}\n\n@media (max-width: 768px) {\n    html, body {\n        padding: 0 !important;\n        margin: 0 !important;\n        width: 100%;\n        overflow-x: hidden;\n    }\n\n    .scispectrum-tabs-container {\n        width: 100% !important;\n        max-width: 100% !important;\n        margin: 0 !important;\n        border-radius: 0 !important;\n        box-shadow: none;\n    }\n\n    .tab-panels {\n        padding: 15px 8px !important;\n    }\n\n    .tab-label {\n        flex: 1 0 48%;\n        font-size: 0.85rem;\n        padding: 12px 2px;\n        box-sizing: border-box;\n    }\n\n    .faq-item {\n        margin: 0 0 15px 0 !important;\n        padding: 12px !important;\n        width: 100%;\n        box-sizing: border-box;\n    }\n}\n\u003c\/style\u003e\n\u003cdiv class=\"scispectrum-tabs-container\"\u003e\n\u003cinput id=\"tab1\" class=\"tab-input\" checked name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab2\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab3\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab4\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e\u003cnav class=\"tab-nav\"\u003e\u003clabel class=\"tab-label\" for=\"tab1\"\u003eOverview\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab2\"\u003eSpecifications\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab3\"\u003eFeatures \u0026amp; Benefits\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab4\"\u003eFAQs\u003c\/label\u003e\u003c\/nav\u003e\n\u003cdiv class=\"tab-panels\"\u003e\n\u003cdiv id=\"content1\" class=\"tab-content\"\u003e\n\u003ch3\u003eEI Auto Melting Point Apparatus Model 1934 – Precision Digital Melting Point Determination System\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEI Auto Melting Point Apparatus Model 1934\u003c\/strong\u003e is a precision-engineered laboratory instrument designed for accurate determination of melting point temperatures of crystalline compounds using capillary tube analysis. Developed using advanced microcontroller technology and precision thermal control engineering, this digital melting point apparatus delivers dependable analytical performance for pharmaceutical laboratories, chemical research facilities, academic institutions, and industrial quality control environments.\u003c\/p\u003e\n\u003cp\u003eThe Model 1934 features intelligent programmable heating functionality that combines rapid heating with controlled slow ramp heating near the expected melting point. Using programmable Plateau and Ramp temperature control, the instrument minimizes temperature overshoot and significantly improves analytical precision, repeatability, and sample testing consistency.\u003c\/p\u003e\n\u003cp\u003eEquipped with a bright 3-digit seven-segment LED display, the apparatus provides direct digital temperature indication along with multiple operational status LEDs including PLATEAU, °C, RAMP, RUN, END, READY, and RECALL for convenient workflow monitoring. The integrated Platinum Resistance Pt100 sensor ensures reliable thermal measurement stability throughout the operating range up to 300°C.\u003c\/p\u003e\n\u003cp\u003eFor enhanced laboratory productivity, the system includes memory storage capability for up to 100 melting point results, retained even after power shutdown. The integrated cooling fan accelerates cooling between analyses, while the dedicated cleaning mode simplifies removal of broken capillary tubes from the heating chamber.\u003c\/p\u003e\n\u003cp\u003eWidely used in pharmaceutical quality control, organic chemistry laboratories, purity testing, compound identification, and research applications, the EI Model 1934 Auto Melting Point Apparatus offers an ideal balance of precision, programmable control, operational simplicity, and dependable laboratory performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content2\" class=\"tab-content\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter \/ Feature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto Melting Point Apparatus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicrocontroller Based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Sample at a Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient to 300°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1°C at 20°C \/ ±2.5°C at 300°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Digit Seven Segment LED Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlatinum Resistance Pt100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRamp Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Scale 1 – 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlateau Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully Programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyboard Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft Touch Membrane Keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLATEAU, °C, RAMP, RUN, END, READY \u0026amp; RECALL LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStores up to 100 Results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Quick Cooling Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCleaning Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal \/ Clean Rotary Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 × 300 × 350 mm (Approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 9 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 230V ±10%, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh Quality Industrial Grade Plastic Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapillary Box, Operation Manual \u0026amp; Dust Cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePharmaceutical QC, Chemical Research, Purity Testing, Compound Identification, Academic Laboratories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content3\" class=\"tab-content\"\u003e\n\u003ch3\u003eCore Features \u0026amp; User Benefits\u003c\/h3\u003e\n\u003cp\u003eThe EI Model 1934 Auto Melting Point Apparatus is designed to provide precise thermal analysis, programmable heating control, and reliable laboratory performance for pharmaceutical and chemical testing applications.\u003c\/p\u003e\n\u003cul class=\"features-list\"\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eAdvanced Microcontroller Technology\u003c\/span\u003e The intelligent microcontroller-based control system delivers stable heating performance and improved analytical reproducibility for accurate melting point determination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eProgrammable Plateau \u0026amp; Ramp Heating\u003c\/span\u003e The apparatus enables rapid heating to a predefined plateau temperature followed by slow controlled ramp heating for enhanced measurement precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eHigh Accuracy Thermal Monitoring\u003c\/span\u003e The integrated Platinum Resistance Pt100 sensor ensures reliable temperature measurement across the full operating range up to 300°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eBright Digital LED Display\u003c\/span\u003e The 3-digit seven-segment LED display provides clear temperature indication and simplified monitoring during laboratory testing procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eIntegrated Result Memory\u003c\/span\u003e Internal storage capability allows retention of up to 100 melting point results, improving laboratory documentation and workflow efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eQuick Cooling System\u003c\/span\u003e The integrated cooling fan reduces chamber cooling time between tests, improving laboratory productivity and minimizing waiting periods.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eUser-Friendly Soft Touch Controls\u003c\/span\u003e Soft touch membrane keys simplify parameter programming and ensure convenient routine laboratory operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eEasy Cleaning Function\u003c\/span\u003e The dedicated Normal\/Clean rotary switch helps remove broken capillary tube fragments safely and efficiently from the heating chamber.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eIdeal for Pharmaceutical \u0026amp; Chemical Laboratories\u003c\/span\u003e Suitable for purity testing, compound characterization, API verification, research studies, and academic laboratory applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content4\" class=\"tab-content\"\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat is the primary application of the EI Auto Melting Point Apparatus Model 1934?\u003c\/p\u003e\n\u003cp\u003eThe EI Model 1934 is primarily used for accurate determination of melting point temperatures of crystalline and organic compounds using capillary tube analysis.\u003c\/p\u003e\n\u003cp\u003eIt is widely used in pharmaceutical quality control laboratories, chemical research facilities, educational institutions, and industrial analytical laboratories.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eHow does programmable ramp heating improve measurement accuracy?\u003c\/p\u003e\n\u003cp\u003eThe programmable ramp heating system allows rapid heating to a predefined plateau temperature before automatically switching to slow controlled heating near the expected melting point.\u003c\/p\u003e\n\u003cp\u003eThis minimizes temperature overshoot and significantly improves analytical precision and repeatability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eDoes the Model 1934 store previous melting point results?\u003c\/p\u003e\n\u003cp\u003eYes, the apparatus includes internal memory storage capability for up to 100 melting point results.\u003c\/p\u003e\n\u003cp\u003eThe stored results remain retained even when the instrument power is switched off, supporting laboratory traceability and documentation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat type of temperature sensor is used in the instrument?\u003c\/p\u003e\n\u003cp\u003eThe Model 1934 uses a Platinum Resistance Pt100 temperature sensor for highly stable and reliable thermal measurement performance.\u003c\/p\u003e\n\u003cp\u003eThis precision sensor improves temperature accuracy and consistency during routine melting point analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhich industries commonly use auto melting point apparatus systems?\u003c\/p\u003e\n\u003cp\u003eAuto melting point apparatus systems are commonly used in pharmaceutical manufacturing, chemical industries, academic research laboratories, material science facilities, and industrial quality control departments.\u003c\/p\u003e\n\u003cp\u003eThey are especially important for purity testing, raw material verification, compound identification, and analytical research applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51461015109878,"sku":"EI-MEL-1934","price":70682.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Auto_Melting_Point_1934_EI-DVI_LED_Display__10909.1759841873.386.513.jpg?v=1786599176"},{"product_id":"ei-dvi-basic-digital-melting-point-apparatus","title":"EI-DVI Basic Digital Melting Point Apparatus with Temperature Controller","description":"\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"19\"\u003e\u003cspan style=\"font-size: 18pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"19\" class=\"ng-star-inserted\"\u003eMelting Point Apparatus - DVI Basic Model With Digital Temperature Controller (EI-DVI)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"553\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"635\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"635\" class=\"ng-star-inserted\" style=\"font-size: 12pt;\"\u003e1. Overview and Core Functionality\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"635\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"669\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"669\" class=\"ng-star-inserted\"\u003eThe Melting Point Apparatus is an essential laboratory instrument used for the accurate determination of the melting point of crystalline or solid samples. This digital version is optimized for precision and ease of observation, making it a reliable tool for analytical processes, identification of substances, and quality control applications, particularly in fields dealing with chemicals, pharmaceuticals, and polymers.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1091\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1091\" class=\"ng-star-inserted\"\u003eThe sample material is accommodated within a sealed capillary tube. This capillary is inserted into the heating mechanism, which operates via an electrical heating block or an immersion heater within an oil bath.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1091\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"1303\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1303\" class=\"ng-star-inserted\"\u003e2. Precise Temperature Control and Measurement\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"1303\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1349\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1349\" class=\"ng-star-inserted\"\u003eThe apparatus utilizes a digital temperature controller for regulating the heating process and providing real-time temperature feedback.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1485\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1485\"\u003eDigital Control:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1501\" class=\"ng-star-inserted\"\u003e Temperature can be easily set directly from the digital controller itself.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1576\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1576\"\u003eTemperature Readout:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1596\" class=\"ng-star-inserted\"\u003e The measured temperature is observed clearly on the digital control panel.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1671\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1671\"\u003eHeating Adjustment:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1690\" class=\"ng-star-inserted\"\u003e Heating rate and temperature can be adjusted using the digital panel controls or via the specialized energy control knob provided on the unit.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1833\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1833\"\u003eSensor Technology:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1851\" class=\"ng-star-inserted\"\u003e Temperature measurement typically relies on a reliable Platinum Resistance (PT-100) sensor for high accuracy.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"1961\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1961\" class=\"ng-star-inserted\"\u003e3. Sample Observation and Comparison\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1997\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1997\" class=\"ng-star-inserted\"\u003eFor rigorous testing, the apparatus is equipped with features designed for clear viewing and verification of the melting process:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2126\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2126\"\u003eObservation:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2138\" class=\"ng-star-inserted\"\u003e The unit includes an eyepiece fitted with a magnifier, ensuring clear observation of the sample as it melts within the capillary. This visual clarity aids in precisely marking the melting point end point.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2343\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2343\"\u003eManual Verification:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2363\" class=\"ng-star-inserted\"\u003e There is a specific provision to fix one standard glass thermometer alongside the capillaries at the top of the apparatus. A dedicated clamp is provided to secure the glass thermometer, allowing the operator to simultaneously observe and compare the sample temperature with an independent reference.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2343\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"2663\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2663\" class=\"ng-star-inserted\"\u003e4. Typical Structure (Oil Bath Configuration)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"2663\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2708\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2708\" class=\"ng-star-inserted\"\u003eWhile dry block options exist, many digital melting point apparatuses feature an oil bath system for uniform heating:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2825\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2825\"\u003eHeating Medium:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2840\" class=\"ng-star-inserted\"\u003e The unit typically contains a silicon oil bath, often having a capacity of around 200 ml, surrounded by a specialized oil immersion heater.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2980\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2980\"\u003eUniformity:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2991\" class=\"ng-star-inserted\"\u003e An in-built magnetic stirrer helps ensure uniform temperature distribution throughout the silicon bath, providing a more consistent and accurate heating environment for the sample.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2980\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"3254\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3254\" class=\"ng-star-inserted\"\u003eTechnical Specifications (DVI Digital Basic Configuration)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"3254\"\u003e \u003c\/div\u003e\n\u003ctable class=\"ng-star-inserted\" data-start-index=\"3312\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3312\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3312\" class=\"ng-star-inserted\"\u003eSpecification\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3325\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3325\" class=\"ng-star-inserted\"\u003eDetail\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3331\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3331\"\u003eModel Type\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3341\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3341\" class=\"ng-star-inserted\"\u003eDigital Melting Point Apparatus (Visual Observation)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3393\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3393\"\u003eBrand\/Series\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3405\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3405\" class=\"ng-star-inserted\"\u003eEI-DVI Basic Model\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3423\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3423\"\u003eHeating Type\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3435\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3435\" class=\"ng-star-inserted\"\u003eElectrical Heating Block or Silicon Oil Bath\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3479\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3479\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3496\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3496\" class=\"ng-star-inserted\"\u003eTypically Ambient (2°C above Room Temp) up to 300°C\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3547\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3547\"\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3565\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3565\" class=\"ng-star-inserted\"\u003ePT-100 Platinum Resistance Sensor\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3598\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3598\"\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3620\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3620\" class=\"ng-star-inserted\"\u003eTypically 1°C (For basic model digital display)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3667\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3667\"\u003eTemperature Control\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3686\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3686\" class=\"ng-star-inserted\"\u003eDigital Controller with Energy Control Knob\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3729\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3729\"\u003eSample Viewing\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3743\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3743\" class=\"ng-star-inserted\"\u003eEyepiece with Magnifier and Illuminated Background\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3793\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3793\"\u003eCapillary Provision\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3812\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3812\" class=\"ng-star-inserted\"\u003eSamples accommodated in standard sealed capillary tubes\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3867\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3867\"\u003eAuxiliary Support\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3884\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3884\" class=\"ng-star-inserted\"\u003eProvision and clamp provided to fix one glass thermometer\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3941\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3941\"\u003eStandard Heating Medium\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3964\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3964\" class=\"ng-star-inserted\"\u003eSilicon oil bath (Approx. 200 ml capacity)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"4006\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"4006\"\u003eStirring\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"4014\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"4014\" class=\"ng-star-inserted\"\u003eBuilt-in magnetic stirrer (if oil bath utilized)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"4062\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"4062\"\u003ePower Supply\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"4074\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"4074\" class=\"ng-star-inserted\"\u003eTypically AC 230 V ± 10%, 50 Hz\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51461015470326,"sku":"EI-MEL-DVI Basic","price":14750.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Melting_Point_Apparatus_-_DVI_Basic_Model_With_Digital_Temp._Controller__76644.1759897742.386.513.jpg?v=1786599178"},{"product_id":"electronics-india-model-934-digital-melting-point-apparatus","title":"Electronics India Digital Melting Point Apparatus Model 934","description":"\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"606\"\u003e\u003cspan style=\"font-size: 18pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"606\" class=\"ng-star-inserted\"\u003eProduct Description: Model 934 Digital Melting Point Apparatus:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"606\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"668\"\u003e\u003cspan style=\"font-size: 14pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"668\" class=\"ng-star-inserted\"\u003eProduct Overview and Core Functionality:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"668\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"707\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"707\" class=\"ng-star-inserted\"\u003eThe \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"711\"\u003eElectronics India Model 934 Digital Melting Point Apparatus\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"770\" class=\"ng-star-inserted\"\u003e is a robust and reliable instrument specifically designed for the accurate measurement of melting points and for checking the melting range of solid samples. Its design emphasizes high accuracy and ease of operation, making it an extremely useful tool, particularly for laboratories in the Pharmaceutical Industry.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"707\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1085\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1085\" class=\"ng-star-inserted\"\u003eThe apparatus utilizes a durable \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1118\"\u003esilicon oil-bath\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1134\" class=\"ng-star-inserted\"\u003e system to provide consistent and controlled heating. The melting point data is presented via a clear digital readout, ensuring precise results required for quality control and research applications.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1085\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"1333\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1333\" class=\"ng-star-inserted\"\u003eHeating System and Uniformity:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"1333\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1362\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1362\" class=\"ng-star-inserted\"\u003eThe heating mechanism centers around a silicon oil-bath beaker of approximately \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1442\"\u003e200 ml capacity\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1457\" class=\"ng-star-inserted\"\u003e. This bath is fitted with a special oil immersion heater and covered with a Teflon or Ptfe cover. To ensure optimal thermal performance, the unit includes an \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1616\"\u003ein-built magnetic stirrer\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1641\" class=\"ng-star-inserted\"\u003e designed to provide uniform heating throughout the silicon oil-bath.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1362\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1710\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1710\" class=\"ng-star-inserted\"\u003eAn electronic controller with an indicator allows the user to precisely adjust the rate of heating of the oil-bath. The heating system is managed via a \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1862\"\u003eHigh\/Low range temperature selector switch\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1904\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"1905\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1905\" class=\"ng-star-inserted\"\u003eDigital Display and Operation.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"1905\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1934\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1934\" class=\"ng-star-inserted\"\u003eThe Model 934 features a highly visible \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1974\"\u003e4 Digit Seven Segment LED Display\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2007\" class=\"ng-star-inserted\"\u003e (or 3 Digit, 7-Segment LED Display depending on specific version). The digital temperature indicator uses a PT100 RTD sensor.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2133\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2133\" class=\"ng-star-inserted\"\u003eA key feature distinguishing the Model 934 is its temperature resolution of \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2209\"\u003e1 °C\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2213\" class=\"ng-star-inserted\"\u003e across the operating range of 0–300 °C.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2133\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2253\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2253\" class=\"ng-star-inserted\"\u003eMeasurement is straightforward:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2253\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2284\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e1. \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2284\" class=\"ng-star-inserted\"\u003eThe ‘Start’ switch initiates the measurement process.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2337\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e2. \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2337\" class=\"ng-star-inserted\"\u003eThe user stops the measurement using the ‘Stop’ switch once the instrument reaches the sample's melting point.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2447\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e3. \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2447\" class=\"ng-star-inserted\"\u003eThe display retains the last temperature recorded when the ‘Stop’ switch was pressed.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2532\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e4. \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2532\" class=\"ng-star-inserted\"\u003eThe ‘Clear’ switch is used to reset the display to zero before the next test.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2532\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"2609\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2609\" class=\"ng-star-inserted\"\u003eSample Observation:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"2609\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2627\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2627\" class=\"ng-star-inserted\"\u003eThe apparatus is engineered to facilitate easy and strain-free observation of the sample capillaries during testing. It includes a \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2758\"\u003elarge magnifier\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2773\" class=\"ng-star-inserted\"\u003e combined with a \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2790\"\u003eglare-free background illuminator\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2823\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2824\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2824\" class=\"ng-star-inserted\"\u003eThe oil-bath cover is designed with three holes specifically for holding the capillaries, one hole for the boiling point tube, and one hole for a thermometer.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2982\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"3064\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3064\" class=\"ng-star-inserted\"\u003eTechnical Specifications (Model 934):\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"3064\"\u003e \u003c\/div\u003e\n\u003ctable class=\"ng-star-inserted\" data-start-index=\"3100\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3100\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3100\" class=\"ng-star-inserted\"\u003eSpecification\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3113\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3113\" class=\"ng-star-inserted\"\u003eDetail\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3119\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3119\"\u003eModel\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3124\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3124\" class=\"ng-star-inserted\"\u003e934\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3127\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3127\"\u003eDisplay Type\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3139\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3139\" class=\"ng-star-inserted\"\u003e4 Digit Seven Segment LED Display\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3172\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3172\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3189\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3189\" class=\"ng-star-inserted\"\u003e0 – 300 °C\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3199\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3199\"\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3221\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3221\" class=\"ng-star-inserted\"\u003e1 °C\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3225\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3225\"\u003eOil-Bath Medium\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3240\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3240\" class=\"ng-star-inserted\"\u003eSilicon Oil-Bath Beaker\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3263\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3263\"\u003eOil-Bath Capacity\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3280\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3280\" class=\"ng-star-inserted\"\u003e200 ml capacity\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3295\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3295\"\u003eCover\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3300\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3300\" class=\"ng-star-inserted\"\u003eTeflon\/Ptfe cover fitted with oil immersion heater (3 holes for capillaries, 1 for boiling point tube, 1 for thermometer)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3421\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3421\"\u003eStirrer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3428\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3428\" class=\"ng-star-inserted\"\u003eIn-built Magnetic Stirrer, Speed Controllable with front knob\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3489\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3489\"\u003eCapillary Glass Tubes\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3510\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3510\" class=\"ng-star-inserted\"\u003e75 mm long, 0.8 – 1.1 mm internal diameter\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3552\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3552\"\u003eBoiling Point Glass Tubes\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3577\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3577\" class=\"ng-star-inserted\"\u003e75 mm long glass tube\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3598\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3598\"\u003ePower Requirement\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3615\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3615\" class=\"ng-star-inserted\"\u003e230 V ± 10%, 50 Hz. AC\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3637\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3637\"\u003eSample Size\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3648\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3648\" class=\"ng-star-inserted\"\u003eFine powder (properly dried), 4 to 6 mm high\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3692\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3692\"\u003eObservation Aids\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3708\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3708\" class=\"ng-star-inserted\"\u003eGlare-free background illuminator and large magnifier\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3761\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3761\"\u003eDimensions (L x B x H)\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3783\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3783\" class=\"ng-star-inserted\"\u003e315 x 290 x 230 mm (Approx.) or 315 x 290 x 290 mm (Approx.)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3843\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3843\"\u003eWeight\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3849\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3849\" class=\"ng-star-inserted\"\u003e12 Kg (Approx.)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3864\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3864\"\u003eKey Features\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3876\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3876\" class=\"ng-star-inserted\"\u003eHighly Accurate \u0026amp; Easy to Operate; Extremely Useful for Pharmaceutical Industry\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3955\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3955\"\u003eSensor Type\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3966\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3966\" class=\"ng-star-inserted\"\u003ePT100 RTD Sensor\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51461015503094,"sku":"EI-MEL-934","price":56522.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Melting_Point_934_LED_display_EI-DVI_Silicon_oil_bath_method__22431.1759899718.386.513.jpg?v=1786599179"},{"product_id":"octovision-digital-melting-point-apparatus-dvi-360c","title":"OCTOVISION Digital Melting Point Apparatus DVI 360°C","description":"\u003cdiv class=\"paragraph heading1 ng-star-inserted\" data-start-index=\"10\"\u003e\u003cspan style=\"font-size: 18pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"10\" class=\"ng-star-inserted\"\u003eHigh Precision Digital Melting Point Apparatus (DVI) with Energy Regulator \u0026amp; 360°C Thermometer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading1 ng-star-inserted\" data-start-index=\"10\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"104\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"104\" class=\"ng-star-inserted\"\u003eProduct Overview and Applications\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"104\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"137\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"137\" class=\"ng-star-inserted\"\u003eThe OCTOVISION Melting Point Apparatus (DVI) is a crucial instrument designed to accurately determine the \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"243\"\u003emelting point of a substance\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"271\" class=\"ng-star-inserted\"\u003e. This versatile unit combines the precision of a digital temperature controller with the stability of a manually adjustable energy regulator, offering flexible and reliable performance for laboratory applications. The apparatus is supplied complete with the necessary accessories, including a 360°C glass thermometer and a box of OES capillary tubes, ensuring immediate operational readiness.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"137\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"664\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"664\" class=\"ng-star-inserted\"\u003ePrecision Control and Observation\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"664\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"697\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"697\" class=\"ng-star-inserted\"\u003eThis apparatus operates by loading a sample into a \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"748\"\u003esealed capillary\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-137\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"764\" class=\"ng-star-inserted\"\u003e. The heating mechanism uses a metallic heating block, which is heated electrically via superior heating elements\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-137\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-137\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"877\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"878\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"878\" class=\"ng-star-inserted\"\u003eThe temperature control incorporates two methods for superior accuracy:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"949\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e1. \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"949\"\u003eDigital Control:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"965\" class=\"ng-star-inserted\"\u003e The digital version (DVI) allows the temperature to be set and observed using a digital temperature control panel\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-137\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1079\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1080\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e2. \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1080\"\u003eEnergy Regulation:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1098\" class=\"ng-star-inserted\"\u003e Temperature can also be adjusted using an \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1141\"\u003eenergy control knob\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1160\" class=\"ng-star-inserted\"\u003e provided\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-137\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1169\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1170\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1170\" class=\"ng-star-inserted\"\u003eSamples in the capillaries are inserted from the top into the metallic heating block, which has holes designed to receive up to three capillary tubes simultaneously, along with a stem type thermometer\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-137\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-137\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1370\" class=\"ng-star-inserted\"\u003e. Observation of the melting process is made through an eyepiece which features a magnifier for enhanced viewing\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-137\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1482\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1483\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1483\" class=\"ng-star-inserted\"\u003eThe apparatus includes a provision and clamp to securely hold one glass thermometer along with the capillaries at the top, allowing the melting temperature of the sample to be visually observed directly\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-137\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1685\" class=\"ng-star-inserted\"\u003e. This apparatus is capable of measuring melting points up to \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1747\"\u003e360°C\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-137\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1752\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1483\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"1753\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1753\" class=\"ng-star-inserted\"\u003eIncluded Components\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"1753\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1772\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1772\" class=\"ng-star-inserted\"\u003eThis complete package ensures you have all the necessary tools for immediate melting point determination:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1877\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1877\" class=\"ng-star-inserted\"\u003eMelting Point Apparatus (Digital Version with Energy Regulator)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1940\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1940\" class=\"ng-star-inserted\"\u003e360°C Glass Thermometer (Included as a provision to observe temperature)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2012\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2012\" class=\"ng-star-inserted\"\u003e1 Box of OES Capillary Tubes (For sample loading)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2012\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"2061\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2061\" class=\"ng-star-inserted\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"2061\"\u003e \u003c\/div\u003e\n\u003ctable class=\"ng-star-inserted\" data-start-index=\"2085\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2085\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2085\" class=\"ng-star-inserted\"\u003eFeature\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2092\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2092\" class=\"ng-star-inserted\"\u003eSpecification\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2105\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2105\" class=\"ng-star-inserted\"\u003eInstrument Type\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2120\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2120\" class=\"ng-star-inserted\"\u003eMelting Point Apparatus (Digital Version – DVI)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2167\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2167\" class=\"ng-star-inserted\"\u003eControl\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2174\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2174\" class=\"ng-star-inserted\"\u003eDigital Temperature Controller \u0026amp; Energy Control Knob\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2226\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2226\" class=\"ng-star-inserted\"\u003eHeating Medium\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2240\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2240\" class=\"ng-star-inserted\"\u003eMetallic Heating Block with superior heating elements\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2293\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2293\" class=\"ng-star-inserted\"\u003eMaximum Temperature\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2312\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2312\" class=\"ng-star-inserted\"\u003eUp to 360°C\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2323\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2323\" class=\"ng-star-inserted\"\u003eSample Capacity\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2338\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2338\" class=\"ng-star-inserted\"\u003eHolds up to three capillary tubes\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2371\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2371\" class=\"ng-star-inserted\"\u003eViewing System\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2385\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2385\" class=\"ng-star-inserted\"\u003eEyepiece with a magnifier\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2410\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2410\" class=\"ng-star-inserted\"\u003eThermometer Included\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2430\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2430\" class=\"ng-star-inserted\"\u003e360°C Glass Thermometer\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2453\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2453\" class=\"ng-star-inserted\"\u003eCapillaries Included\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2473\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2473\" class=\"ng-star-inserted\"\u003e1 Box of OES Capillary Tubes\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2501\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2501\" class=\"ng-star-inserted\"\u003eThermometer Holding\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2520\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2520\" class=\"ng-star-inserted\"\u003eClamp provided for fixing the glass thermometer\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Octovision","offers":[{"title":"Default Title","offer_id":51461015535862,"sku":"EI-MEL-DVI","price":4425.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Melting_Point_Apparatus_-_DVI_Basic_Model_With_Digital_Temp._Controller_2__98236.1759898683.386.513.jpg?v=1786599180"},{"product_id":"electronics-india-model-935-digital-melting-point-apparatus","title":"Electronics India Digital Melting Point Apparatus Model 935 | 0.1°C Resolution | 0-300°C Range","description":"\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"895\"\u003e\u003cspan style=\"font-size: 18pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"895\" class=\"ng-star-inserted\"\u003eProduct Overview and Application:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"895\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"927\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"927\" class=\"ng-star-inserted\"\u003eThe Digital Melting Point Apparatus Model 935, manufactured by Electronics India (EI), is a specialized laboratory instrument designed for the accurate measurement and observation of melting points and melting ranges of solid samples\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1160\" class=\"ng-star-inserted\"\u003e. The determination of a substance's melting point is crucial for identifying pure substances and verifying sample purity in various scientific fields\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1310\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1311\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1311\" class=\"ng-star-inserted\"\u003eThis apparatus is particularly useful for the \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1357\"\u003ePharmaceutical Industry\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1380\" class=\"ng-star-inserted\"\u003e, where assessing the purity of active pharmaceutical ingredients (API) and ensuring adherence to specifications is vital for drug safety and efficacy\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1530\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"1531\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1531\" class=\"ng-star-inserted\"\u003eAdvanced Measurement Technology\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1562\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1562\" class=\"ng-star-inserted\"\u003eThe Model 935 is engineered for high accuracy and ease of operation\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1629\" class=\"ng-star-inserted\"\u003e. It uses a digital temperature indicator equipped with a \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1687\"\u003ePT100 RTD sensor\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1703\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1562\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"1704\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1704\" class=\"ng-star-inserted\"\u003ePrecision Heating and Temperature Control:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"1704\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1745\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1745\" class=\"ng-star-inserted\"\u003eThe core system involves a \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1772\"\u003e200 ml capacity silicon oil-bath\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1804\" class=\"ng-star-inserted\"\u003e covered with a PTFE or Teflon cover\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1840\" class=\"ng-star-inserted\"\u003e. Uniform heating across the bath is ensured by an \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1891\"\u003ein-built magnetic stirrer\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1916\" class=\"ng-star-inserted\"\u003e, with the stirrer speed being controllable via a front knob\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1976\" class=\"ng-star-inserted\"\u003e. An electronic controller allows for precise adjustment of the silicon oil-bath heating rate\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2069\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"2070\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2070\" class=\"ng-star-inserted\"\u003eDigital Display and Resolution\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2100\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2100\" class=\"ng-star-inserted\"\u003eModel 935 offers high resolution and clear visibility. It utilizes a \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2169\"\u003e4 Digit, 7-Segment LED Display\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2199\" class=\"ng-star-inserted\"\u003e. The digital readout provides a high \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2237\"\u003eresolution of 0.1 °C\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2257\" class=\"ng-star-inserted\"\u003e, enabling precise recording of the melting range.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading4 ng-star-inserted\" data-start-index=\"2307\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2307\" class=\"ng-star-inserted\"\u003eObservation and Operation\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2332\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2332\" class=\"ng-star-inserted\"\u003eThe apparatus features a \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2357\"\u003elarge magnifier\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2372\" class=\"ng-star-inserted\"\u003e and a \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2379\"\u003eglare-free background illuminator\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2412\" class=\"ng-star-inserted\"\u003e to facilitate stain-free observation of the sample as it melts inside the capillary tube\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2501\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2332\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2502\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2502\" class=\"ng-star-inserted\"\u003eOperational control includes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2502\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2531\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2531\"\u003eStart Switch:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2544\" class=\"ng-star-inserted\"\u003e Used to initiate the measurement of the melting point\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2598\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2599\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2599\"\u003eStop Switch:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2611\" class=\"ng-star-inserted\"\u003e Used to halt the measurement once the sample has melted, with the display showing the last temperature recorded\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2723\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2724\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2724\"\u003eClear Switch:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2737\" class=\"ng-star-inserted\"\u003e Used to reset the display reading to zero\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2779\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2724\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"2780\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2780\" class=\"ng-star-inserted\"\u003eSpecifications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"2780\"\u003e \u003c\/div\u003e\n\u003ctable class=\"ng-star-inserted\" data-start-index=\"2794\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2794\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2794\" class=\"ng-star-inserted\"\u003eFeature\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2801\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2801\" class=\"ng-star-inserted\"\u003eSpecification (Model 935)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2826\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2826\"\u003eBrand\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2831\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2831\" class=\"ng-star-inserted\"\u003eElectronics India (EI)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2853\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2853\"\u003eModel\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2858\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2858\" class=\"ng-star-inserted\"\u003e935\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2861\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2861\"\u003eType\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2865\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2865\" class=\"ng-star-inserted\"\u003eDigital Melting Point Apparatus\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2896\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2896\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2913\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2913\" class=\"ng-star-inserted\"\u003e0 – 300 °C\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2923\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2923\"\u003eResolution\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2933\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2933\" class=\"ng-star-inserted\"\u003e0.1 °C\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2939\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2939\"\u003eDisplay\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2946\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2946\" class=\"ng-star-inserted\"\u003e4 Digit, 7-Segment LED Display\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2976\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2976\"\u003eHeating System\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2990\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2990\" class=\"ng-star-inserted\"\u003eSilicon Oil-Bath (200 ml capacity) with Oil Immersion Heater\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3050\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3050\"\u003eStirring\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3058\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3058\" class=\"ng-star-inserted\"\u003eIn-built Magnetic Stirrer, speed controllable with front knob\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3119\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3119\"\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3137\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3137\" class=\"ng-star-inserted\"\u003ePT100 RTD sensor\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3153\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3153\"\u003eObservation\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3164\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3164\" class=\"ng-star-inserted\"\u003eGlare-free Illuminator and Large Magnifier\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3206\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3206\"\u003eCapillary Tube Size\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3225\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3225\" class=\"ng-star-inserted\"\u003e75 mm long, 0.8 – 1.1 mm internal diameter\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3267\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3267\"\u003eBoiling Point Tubes\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3286\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3286\" class=\"ng-star-inserted\"\u003e75 mm long glass tube\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3307\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3307\"\u003eRecommended Sample Amount\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3332\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3332\" class=\"ng-star-inserted\"\u003eFine, dry powder, 4 – 6 mm high in the tube\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3375\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3375\"\u003ePower\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3380\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3380\" class=\"ng-star-inserted\"\u003e230 V ± 10% AC, 50 Hz\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3401\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3401\"\u003eDimensions (L x B x H)\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3423\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3423\" class=\"ng-star-inserted\"\u003e315 x 290 x 230 mm (Approx.)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3451\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3451\"\u003eWeight\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3457\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3457\" class=\"ng-star-inserted\"\u003e12 Kg (Approx.)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3472\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3472\"\u003eOuter Body Material\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3491\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3491\" class=\"ng-star-inserted\"\u003ePlastic (or Mild Steel\/Rectangular shape in some listings)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"3549\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"3549\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3549\" class=\"ng-star-inserted\"\u003eIncluded Accessories and Components:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"3549\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3584\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3584\" class=\"ng-star-inserted\"\u003eThe apparatus comes complete with necessary accessories for immediate use\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3657\" class=\"ng-star-inserted\"\u003e. These typically include:\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3683\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3683\" class=\"ng-star-inserted\"\u003eA box of Capillaries\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3703\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3704\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3704\" class=\"ng-star-inserted\"\u003eBoiling Point Tubes (usually 2 sets)\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3740\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3741\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3741\" class=\"ng-star-inserted\"\u003eThermometer with a range of 0 – 360 °C\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3779\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3780\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3780\" class=\"ng-star-inserted\"\u003eMagnetic Capsule\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3796\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3797\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3797\" class=\"ng-star-inserted\"\u003eBottle of Silicon Oil (e.g., 250 ml)\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3833\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3834\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3834\" class=\"ng-star-inserted\"\u003eGlass Cylindrical Beaker with Teflon\/PTFE cover fitted with an immersion heater\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3913\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3914\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3914\" class=\"ng-star-inserted\"\u003eOperation Manual and Dust Cover\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"xap-inline-dialog citation-marker ng-star-inserted\" aria-haspopup=\"dialog\" aria-describedby=\"cdk-describedby-message-ng-1-103\" data-disabled=\"false\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e\u003cbutton class=\"citation-marker\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3945\" class=\"ng-star-inserted\"\u003e.\u003c\/span\u003e\n\u003c\/div\u003e","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51461015568630,"sku":"EI-MEL-935","price":57702.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Melting_Point_934_LED_display_EI-DVI_Silicon_oil_bath_method__23409.1759899920.386.513.jpg?v=1786599181"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/collections\/melting-point-apparatus.png?v=1786700796","url":"https:\/\/scispectrum.in\/collections\/melting-point-apparatus.oembed","provider":"SciSpectrum Lab Essentials","version":"1.0","type":"link"}