{"product_id":"advance-manual-polarimeter","title":"ADVANCE Manual Polarimeter Standard Model PA-1R","description":"\u003cdiv class=\"powr-chat\" id=\"1abb102c_1753877895\"\u003e\u003c\/div\u003e\n\u003ch2\u003eADVANCE Manual Polarimeter\u003c\/h2\u003e\n\u003cdiv class=\"Message_messageTextContainer__w64Sc\"\u003e\n\u003cdiv class=\"Message_selectableText__SQ8WH\"\u003e\n\u003cdiv class=\"Markdown_markdownContainer__Tz3HQ\"\u003e\n\u003cdiv class=\"Prose_prose__7AjXb Prose_presets_prose__H9VRM Prose_presets_theme-hi-contrast__LQyM9 Prose_presets_preset-lg__5CAiC\"\u003e\n\u003ch3\u003eADVANCE Manual Polarimeter (Standard Model: PA-1R)\u003c\/h3\u003e\nThe \u003cstrong\u003eADVANCE PA-1R Standard Model\u003c\/strong\u003e is a robust and reliable manual polarimeter, engineered for accurate determination of optical rotation in educational and industrial laboratories. It is particularly well-suited for applications in the pharmaceutical, chemical, sugar, and food industries where precise, repeatable measurements are essential.\n\nThis model is distinguished by its highly sensitive \u003cstrong\u003etriple shadow eyepiece\u003c\/strong\u003e. This advanced optical system presents the user with three distinct fields of view, allowing for a more precise and strain-free determination of the balance point compared to simpler half-shade systems. This feature significantly improves the accuracy and repeatability of measurements.\n\nThe instrument features a full-circle \u003cstrong\u003eangular scale of 0-360°\u003c\/strong\u003e, which is read using a clear vernier scale. The precision-engraved scale and finely finished rotating mechanism allow for a readability (often referred to as accuracy) of \u003cstrong\u003e0.05°\u003c\/strong\u003e, ensuring high-quality results. The PA series is designed to accommodate sample tubes up to \u003cstrong\u003e220 mm\u003c\/strong\u003e in length, providing flexibility for analyzing samples of varying concentrations.\n\nA key feature of this model is the \u003cstrong\u003eintegrated lighting assembly\u003c\/strong\u003e, which houses the monochromatic light source within the instrument's base. This self-contained design saves valuable bench space, provides stable illumination, and eliminates the need for a separate transformer and lamp housing.\n\n\u003cstrong\u003eKey Features:\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eTriple Shadow System:\u003c\/strong\u003e Offers a highly sensitive visual method for finding the balance point, ensuring greater accuracy and strain-free viewing.\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eFull 360° Measurement Scale:\u003c\/strong\u003e The angular scale covers a complete 0-360° range, suitable for all types of optically active samples. ADVANCE Manual Polarimeter\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Vernier:\u003c\/strong\u003e The precision vernier provides a fine readability of 0.05°, allowing for accurate and direct readings of the rotation angle. ADVANCE Manual Polarimeter\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eIntegrated Lighting:\u003c\/strong\u003e The self-contained light source provides immediate, stable illumination in a compact, space-saving design.\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eLarge Sample Compartment:\u003c\/strong\u003e Designed to accept sample tubes up to 220 mm in length, making it versatile for various analytical needs. ADVANCE Manual Polarimeter\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built with a sturdy, all-metal body to ensure stability and long-term reliability in a laboratory environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eWhat's in the Box: ADVANCE Manual Polarimeter\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eADVANCE PA-1R Polarimeter Main Unit\u003c\/li\u003e\n \t\u003cli\u003eSample Tube (220 mm)\u003c\/li\u003e\n \t\u003cli\u003eAdditional Sample Tubes (typically 100 mm and 200 mm)\u003c\/li\u003e\n \t\u003cli\u003eIntegrated Lighting Assembly\u003c\/li\u003e\n \t\u003cli\u003eDust Cover\u003c\/li\u003e\n \t\u003cli\u003eInstruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications ADVANCE Manual Polarimeter\u003c\/h3\u003e\n\u003cdiv class=\"MarkdownTable_tableContainer__2k5Kh\" tabindex=\"0\" role=\"region\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePA-1R Standard Model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADVANCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShadow System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTriple Shadow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 360° (Angular)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVernier Readability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Tube Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Lighting Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAll-metal body with a stable base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cstrong\u003eIdeal Applications: ADVANCE Manual Polarimeter\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eQuality control in the pharmaceutical and chemical industries.\u003c\/li\u003e\n \t\u003cli\u003eConcentration analysis in the sugar and foodstuff sectors.\u003c\/li\u003e\n \t\u003cli\u003eTesting of essential oils and other optically active substances.\u003c\/li\u003e\n \t\u003cli\u003eTeaching principles of optical isomerism in universities and colleges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Message_messageMetadataContainer__nBPq7\"\u003e\u003c\/div\u003e","brand":"Advance","offers":[{"title":"Default Title","offer_id":51460968218870,"sku":"ADV-POL-APA1R","price":72570.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/ADVANCE_Manual_Polarimeter_Standard_Model_PA-1R__04049.1751953933.386.513_f766b524-d0d7-4a9e-9107-e25a8b88ef5d.jpg?v=1786598973","url":"https:\/\/scispectrum.in\/products\/advance-manual-polarimeter","provider":"SciSpectrum Lab Essentials","version":"1.0","type":"link"}