{"product_id":"digital-bomb-calorimeter-bcm-series","title":"Digital Bomb Calorimeter BCM Series","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e\n:root {\n    --primary-blue:#004a99;\n    --hover-blue:#0056b3;\n    --bg-gray:#f8f9fa;\n    --text-color:#333;\n    --border-color:#ddd;\n    --white:#ffffff;\n}\n\nbody {\n    font-family:'Segoe UI',Tahoma,Verdana,sans-serif;\n    background:var(--bg-gray);\n    color:var(--text-color);\n}\n\n.scispectrum-tabs-container {\n    max-width:1200px;\n    margin:auto;\n    background:#fff;\n    border-radius:8px;\n    box-shadow:0 4px 15px rgba(0,0,0,0.05);\n    overflow:hidden;\n}\n\n.tab-input{display:none;}\n\n.tab-nav{\n    display:flex;\n    flex-wrap:wrap;\n    border-bottom:2px solid var(--border-color);\n}\n\n.tab-label{\n    flex:1;\n    padding:15px;\n    text-align:center;\n    font-weight:600;\n    color:var(--primary-blue);\n    cursor:pointer;\n    border-bottom:3px solid transparent;\n}\n\n.tab-label:hover{\n    background:rgba(0,74,153,0.05);\n}\n\n#tab1:checked ~ .tab-nav label[for=\"tab1\"],\n#tab2:checked ~ .tab-nav label[for=\"tab2\"],\n#tab3:checked ~ .tab-nav label[for=\"tab3\"],\n#tab4:checked ~ .tab-nav label[for=\"tab4\"]{\n    border-bottom-color:var(--primary-blue);\n}\n\n.tab-panels{padding:30px;}\n.tab-content{display:none;}\n\n#tab1:checked ~ .tab-panels #content1,\n#tab2:checked ~ .tab-panels #content2,\n#tab3:checked ~ .tab-panels #content3,\n#tab4:checked ~ .tab-panels #content4{\n    display:block;\n}\n\nh3{color:var(--primary-blue);}\n\n\/* TABLE *\/\n.spec-table{\n    width:100%;\n    border-collapse:collapse;\n}\n.spec-table th,.spec-table td{\n    padding:12px;\n    border-bottom:1px solid var(--border-color);\n}\n.spec-table th{\n    background:var(--primary-blue);\n    color:#fff;\n}\n\n\/* FEATURES *\/\n.features-list{\n    list-style:none;\n    padding:0;\n    display:grid;\n    grid-template-columns:repeat(auto-fit,minmax(260px,1fr));\n    gap:20px;\n}\n.features-list li{\n    border:1px solid var(--border-color);\n    padding:18px;\n    border-radius:6px;\n    padding-left:45px;\n    position:relative;\n}\n.features-list li::before{\n    content:\"✓\";\n    position:absolute;\n    left:15px;\n    color:var(--primary-blue);\n    font-weight:bold;\n}\n\n\/* FAQ FIXED (WITH LINE) *\/\n.faq-item{\n    padding-bottom:15px;\n    margin-bottom:20px;\n    border-bottom:1px solid #ccc; \/* ✅ THIS FIXES YOUR ISSUE *\/\n}\n.faq-question{\n    font-weight:600;\n    color:var(--primary-blue);\n    margin-bottom:5px;\n}\n\n@media(max-width:768px){\n    .tab-label{font-size:0.85rem;}\n}\n\u003c\/style\u003e\n\u003cdiv class=\"scispectrum-tabs-container\"\u003e\n\u003cinput id=\"tab1\" class=\"tab-input\" checked name=\"tabs\" type=\"radio\"\u003e \u003cinput id=\"tab2\" class=\"tab-input\" name=\"tabs\" type=\"radio\"\u003e \u003cinput id=\"tab3\" class=\"tab-input\" name=\"tabs\" type=\"radio\"\u003e \u003cinput id=\"tab4\" class=\"tab-input\" name=\"tabs\" type=\"radio\"\u003e\u003cnav class=\"tab-nav\"\u003e\u003clabel class=\"tab-label\" for=\"tab1\"\u003eOverview\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab2\"\u003eSpecifications\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab3\"\u003eFeatures \u0026amp; Benefits\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab4\"\u003eFAQs\u003c\/label\u003e\u003c\/nav\u003e\n\u003cdiv class=\"tab-panels\"\u003e\n\u003c!-- OVERVIEW --\u003e\n\u003cdiv id=\"content1\" class=\"tab-content\"\u003e\n\u003ch3\u003eDigital Bomb Calorimeter BCM Series – Accurate Calorific Value Testing Solution\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDigital Bomb Calorimeter BCM Series\u003c\/strong\u003e is a precision laboratory instrument designed for accurate determination of \u003cstrong\u003ecalorific value, heat of combustion, and sulphur content\u003c\/strong\u003e across a wide range of materials including coal, fuel, food, and biomass samples.\u003c\/p\u003e\n\u003cp\u003eBuilt with \u003cstrong\u003eisothermal measurement technology\u003c\/strong\u003e, this calorimeter ensures highly reliable results with temperature resolution up to \u003cstrong\u003e0.001°C\u003c\/strong\u003e. The innovative \u003cstrong\u003epush-fit oxygen filling system\u003c\/strong\u003e simplifies operation while enhancing safety and reducing testing time.\u003c\/p\u003e\n\u003cp\u003eIdeal for laboratories, research institutions, and industrial applications, the BCM Series delivers \u003cstrong\u003efast testing (10–15 minutes)\u003c\/strong\u003e, robust construction, and compliance with BIS and IP standards for dependable performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003cdiv id=\"content2\" class=\"tab-content\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e1000 – 10000 Cal\/gm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003eUp to 0.001°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting Time\u003c\/td\u003e\n\u003ctd\u003e10 – 15 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Principle\u003c\/td\u003e\n\u003ctd\u003eIsothermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen Filling\u003c\/td\u003e\n\u003ctd\u003ePush Fit \/ Auto (Model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Jacket\u003c\/td\u003e\n\u003ctd\u003eChromium Plated Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Vessel\u003c\/td\u003e\n\u003ctd\u003eChromium Plated Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e230V ±10V, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5 KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd\u003e10°C – 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- FEATURES --\u003e\n\u003cdiv id=\"content3\" class=\"tab-content\"\u003e\n\u003ch3\u003eCore Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul class=\"features-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Precision Measurement\u003c\/strong\u003e\u003cbr\u003eAccurate calorific value testing with temperature resolution up to 0.001°C ensures reliable laboratory results.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid Testing Efficiency\u003c\/strong\u003e\u003cbr\u003eComplete calorific analysis in just 10–15 minutes, improving laboratory productivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInnovative Push-Fit Gas Filling\u003c\/strong\u003e\u003cbr\u003eReduces oxygen charging time and prevents damage to gas valves for safer operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Safety Protection\u003c\/strong\u003e\u003cbr\u003eIntegrated safety relief valve and high-pressure tested bomb ensure user safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction\u003c\/strong\u003e\u003cbr\u003eChromium plated copper body enhances durability and corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Industry Applications\u003c\/strong\u003e\u003cbr\u003eSuitable for coal, petroleum, food, agriculture, and research laboratory analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv id=\"content4\" class=\"tab-content\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat is a digital bomb calorimeter used for?\u003c\/p\u003e\n\u003cp\u003eA digital bomb calorimeter is used to measure the calorific value and heat of combustion of materials like coal, fuel, food, and biomass. It provides precise energy content analysis for laboratory testing, industrial quality control, and research applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat is the testing time for the BCM Series calorimeter?\u003c\/p\u003e\n\u003cp\u003eThe Digital Bomb Calorimeter BCM Series completes calorific value testing within 10 to 15 minutes. This fast testing capability improves laboratory efficiency while maintaining high accuracy for energy content analysis of various materials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat is the temperature resolution of this calorimeter?\u003c\/p\u003e\n\u003cp\u003eThe BCM Series offers high precision temperature resolution up to 0.001°C, enabling highly accurate measurement of heat changes during combustion. This ensures reliable calorific value determination for research and industrial applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat industries use a bomb calorimeter?\u003c\/p\u003e\n\u003cp\u003eBomb calorimeters are widely used in coal analysis, petroleum testing, food industry, agriculture, research laboratories, and educational institutions for determining energy content and calorific values of different materials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat safety features are included in the BCM Series?\u003c\/p\u003e\n\u003cp\u003eThe BCM Series includes a safety relief valve and high-pressure tested bomb chamber to ensure safe operation. It is tested as per BIS and IP standards, providing reliable and secure calorific testing in laboratory environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\":\"https:\/\/schema.org\",\n\"@type\":\"FAQPage\",\n\"mainEntity\":[\n{\n\"@type\":\"Question\",\n\"name\":\"What is a digital bomb calorimeter used for?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A digital bomb calorimeter is used to measure the calorific value and heat of combustion of materials like coal, fuel, food, and biomass. It provides precise energy content analysis for laboratory testing, industrial quality control, and research applications.\"}\n},\n{\n\"@type\":\"Question\",\n\"name\":\"What is the testing time for the BCM Series calorimeter?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The Digital Bomb Calorimeter BCM Series completes calorific value testing within 10 to 15 minutes. This fast testing capability improves laboratory efficiency while maintaining high accuracy for energy content analysis of various materials.\"}\n},\n{\n\"@type\":\"Question\",\n\"name\":\"What is the temperature resolution of this calorimeter?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The BCM Series offers high precision temperature resolution up to 0.001°C, enabling highly accurate measurement of heat changes during combustion. This ensures reliable calorific value determination for research and industrial applications.\"}\n},\n{\n\"@type\":\"Question\",\n\"name\":\"What industries use a bomb calorimeter?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Bomb calorimeters are widely used in coal analysis, petroleum testing, food industry, agriculture, research laboratories, and educational institutions for determining energy content and calorific values of different materials.\"}\n},\n{\n\"@type\":\"Question\",\n\"name\":\"What safety features are included in the BCM Series?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The BCM Series includes a safety relief valve and high-pressure tested bomb chamber to ensure safe operation. It is tested as per BIS and IP standards, providing reliable and secure calorific testing in laboratory environments.\"}\n}\n]\n}\n\u003c\/script\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Advance","offers":[{"title":"Default Title","offer_id":51460962615542,"sku":"BCMP","price":202370.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Digital_Bomb_Calorimeter_BCM_Series__01330.1754476533.386.513_f6d62fd7-0751-451e-a2bb-05f8478907e6.jpg?v=1786598845","url":"https:\/\/scispectrum.in\/products\/digital-bomb-calorimeter-bcm-series","provider":"SciSpectrum Lab Essentials","version":"1.0","type":"link"}