{"product_id":"dry-bath-incubator-model-352-pid-digital","title":"Dry Bath Incubator Model 352 - Digital, PID Controlled (100°C)","description":"\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"876\"\u003e\u003cspan style=\"font-size: 14pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"876\" class=\"ng-star-inserted\"\u003eDry Bath Incubator Model 352: Precision Temperature Control for Laboratory Applications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"876\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"963\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"963\" class=\"ng-star-inserted\"\u003eThe Dry Bath Incubator Model 352 is a highly sensitive, microcontroller-based instrument engineered to provide precise and constant temperatures for demanding laboratory tasks. It controls the heating of a thermally conducting block, ensuring reliable temperature uniformity for your samples.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1255\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"1255\" class=\"ng-star-inserted\"\u003eThis model is ideal for environments requiring highly controlled thermal conditions, utilizing advanced electronic regulation to guarantee precision for critical experiments.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1255\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"1429\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"1429\" class=\"ng-star-inserted\"\u003eAdvanced Design and Control:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"1429\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1456\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"1456\" class=\"ng-star-inserted\"\u003eThe core of the Model 352 features a specially fabricated block designed to accommodate 24 standard test tubes, each up to 12 mm in diameter. The direct contact between the test tubes and the block walls ensures efficient heat transfer, delivering precise temperatures to the contents.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1741\"\u003e\n\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"1741\" class=\"ng-star-inserted\"\u003eTemperature management is handled by a precision temperature sensor (LM 35 Semi Conductor) and a highly sensitive automatic electronic temperature controller. This system utilizes advanced \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1930\"\u003ePID (Software Controlled) technology\u003c\/strong\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"1966\" class=\"ng-star-inserted\"\u003e for exceptional stability and accuracy. Operational status and settings are easily viewed via a large 16x2 line alphanumeric LCD display, complete with a backlit feature for clarity.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"2149\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2149\" class=\"ng-star-inserted\"\u003eVersatile Laboratory Applications\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2182\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2182\" class=\"ng-star-inserted\"\u003eThe Dry Bath Incubator Model 352 is widely used across various scientific, clinical, and industrial fields due to its high accuracy and reliable performance.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2182\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2339\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2339\"\u003eKey areas of application include:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2339\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2372\"\u003e\n\u003cspan _ngcontent-ng-c3274250709=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2372\"\u003eMolecular Biology:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2390\" class=\"ng-star-inserted\"\u003e Essential for DNA amplification, preparation steps for electrophoresis (pre-degeneration), and solidification procedures.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2512\"\u003e\n\u003cspan _ngcontent-ng-c3274250709=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2512\"\u003eSample Management:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2530\" class=\"ng-star-inserted\"\u003e Used broadly for samples cultivation, preservation, and chemical reactions.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2606\"\u003e\n\u003cspan _ngcontent-ng-c3274250709=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2606\"\u003eIndustry and Research:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2628\" class=\"ng-star-inserted\"\u003e Critical for use in clinical diagnostics, pharmaceutical research, chemical analysis, food safety testing, environmental monitoring, and general quality inspection processes.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2606\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"2803\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2803\" class=\"ng-star-inserted\" style=\"font-size: 12pt;\"\u003eTechnical Specifications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"2803\"\u003e \u003c\/div\u003e\n\u003ctable class=\"ng-star-inserted\" data-start-index=\"2827\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2827\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2827\" class=\"ng-star-inserted\"\u003eParameter\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2836\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2836\" class=\"ng-star-inserted\"\u003eDetail\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2842\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2842\"\u003eModel\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2847\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2847\" class=\"ng-star-inserted\"\u003e352\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2850\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2850\"\u003eInstrument Type\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2865\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2865\" class=\"ng-star-inserted\"\u003eMicrocontroller-based Dry Bath Incubator\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2905\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2905\"\u003eBlock Size\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2915\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2915\" class=\"ng-star-inserted\"\u003e24 holes for 12 mm test tubes\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2944\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2944\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2961\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"2961\" class=\"ng-star-inserted\"\u003e+5°C Above ambient up to 100°C\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2991\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2991\"\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3011\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"3011\" class=\"ng-star-inserted\"\u003e± 2°C\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3016\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3016\"\u003eTemperature Controller\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3038\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"3038\" class=\"ng-star-inserted\"\u003ePID (Software Controlled)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3063\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3063\"\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3081\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"3081\" class=\"ng-star-inserted\"\u003eLM 35 (Semi Conductor)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3103\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3103\"\u003eMaximum Heating Power\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3124\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"3124\" class=\"ng-star-inserted\"\u003e125 W\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3129\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3129\"\u003eTimer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3134\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"3134\" class=\"ng-star-inserted\"\u003e1-99 Minutes\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3146\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3146\"\u003eDisplay\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3153\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"3153\" class=\"ng-star-inserted\"\u003e16x2 Line Alphanumeric LCD Display (with backlit)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3202\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3202\"\u003ePower Supply\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3214\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"3214\" class=\"ng-star-inserted\"\u003e230V ±10% AC, 50Hz\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3232\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3232\"\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3254\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"3254\" class=\"ng-star-inserted\"\u003e190 x 220 x 125 mm\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3272\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3272\"\u003eWeight\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3278\"\u003e\u003cspan _ngcontent-ng-c3274250709=\"\" data-start-index=\"3278\" class=\"ng-star-inserted\"\u003e2.70 Kgs. (Approx.)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51461014257910,"sku":"EI-INC-352","price":10030.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Untitled_design_3__98539.1759741027.386.513.jpg?v=1786599154","url":"https:\/\/scispectrum.in\/products\/dry-bath-incubator-model-352-pid-digital","provider":"SciSpectrum Lab Essentials","version":"1.0","type":"link"}