{"product_id":"ei-dvi-basic-digital-melting-point-apparatus","title":"EI-DVI Basic Digital Melting Point Apparatus with Temperature Controller","description":"\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"19\"\u003e\u003cspan style=\"font-size: 18pt;\"\u003e\u003cstrong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"19\" class=\"ng-star-inserted\"\u003eMelting Point Apparatus - DVI Basic Model With Digital Temperature Controller (EI-DVI)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"553\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"635\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"635\" class=\"ng-star-inserted\" style=\"font-size: 12pt;\"\u003e1. Overview and Core Functionality\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"635\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"669\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"669\" class=\"ng-star-inserted\"\u003eThe Melting Point Apparatus is an essential laboratory instrument used for the accurate determination of the melting point of crystalline or solid samples. This digital version is optimized for precision and ease of observation, making it a reliable tool for analytical processes, identification of substances, and quality control applications, particularly in fields dealing with chemicals, pharmaceuticals, and polymers.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1091\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1091\" class=\"ng-star-inserted\"\u003eThe sample material is accommodated within a sealed capillary tube. This capillary is inserted into the heating mechanism, which operates via an electrical heating block or an immersion heater within an oil bath.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1091\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"1303\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1303\" class=\"ng-star-inserted\"\u003e2. Precise Temperature Control and Measurement\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"1303\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1349\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1349\" class=\"ng-star-inserted\"\u003eThe apparatus utilizes a digital temperature controller for regulating the heating process and providing real-time temperature feedback.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1485\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1485\"\u003eDigital Control:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1501\" class=\"ng-star-inserted\"\u003e Temperature can be easily set directly from the digital controller itself.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1576\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1576\"\u003eTemperature Readout:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1596\" class=\"ng-star-inserted\"\u003e The measured temperature is observed clearly on the digital control panel.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1671\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1671\"\u003eHeating Adjustment:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1690\" class=\"ng-star-inserted\"\u003e Heating rate and temperature can be adjusted using the digital panel controls or via the specialized energy control knob provided on the unit.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1833\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"1833\"\u003eSensor Technology:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1851\" class=\"ng-star-inserted\"\u003e Temperature measurement typically relies on a reliable Platinum Resistance (PT-100) sensor for high accuracy.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"1961\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1961\" class=\"ng-star-inserted\"\u003e3. Sample Observation and Comparison\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"1997\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"1997\" class=\"ng-star-inserted\"\u003eFor rigorous testing, the apparatus is equipped with features designed for clear viewing and verification of the melting process:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2126\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2126\"\u003eObservation:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2138\" class=\"ng-star-inserted\"\u003e The unit includes an eyepiece fitted with a magnifier, ensuring clear observation of the sample as it melts within the capillary. This visual clarity aids in precisely marking the melting point end point.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2343\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2343\"\u003eManual Verification:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2363\" class=\"ng-star-inserted\"\u003e There is a specific provision to fix one standard glass thermometer alongside the capillaries at the top of the apparatus. A dedicated clamp is provided to secure the glass thermometer, allowing the operator to simultaneously observe and compare the sample temperature with an independent reference.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2343\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"2663\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2663\" class=\"ng-star-inserted\"\u003e4. Typical Structure (Oil Bath Configuration)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading3 ng-star-inserted\" data-start-index=\"2663\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2708\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2708\" class=\"ng-star-inserted\"\u003eWhile dry block options exist, many digital melting point apparatuses feature an oil bath system for uniform heating:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2825\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2825\"\u003eHeating Medium:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2840\" class=\"ng-star-inserted\"\u003e The unit typically contains a silicon oil bath, often having a capacity of around 200 ml, surrounded by a specialized oil immersion heater.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2980\"\u003e\n\u003cspan _ngcontent-ng-c1904016421=\"\" class=\"ng-star-inserted\"\u003e• \u003c\/span\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"2980\"\u003eUniformity:\u003c\/strong\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"2991\" class=\"ng-star-inserted\"\u003e An in-built magnetic stirrer helps ensure uniform temperature distribution throughout the silicon bath, providing a more consistent and accurate heating environment for the sample.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"2980\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"3254\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3254\" class=\"ng-star-inserted\"\u003eTechnical Specifications (DVI Digital Basic Configuration)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"paragraph heading2 ng-star-inserted\" data-start-index=\"3254\"\u003e \u003c\/div\u003e\n\u003ctable class=\"ng-star-inserted\" data-start-index=\"3312\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3312\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3312\" class=\"ng-star-inserted\"\u003eSpecification\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3325\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3325\" class=\"ng-star-inserted\"\u003eDetail\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3331\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3331\"\u003eModel Type\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3341\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3341\" class=\"ng-star-inserted\"\u003eDigital Melting Point Apparatus (Visual Observation)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3393\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3393\"\u003eBrand\/Series\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3405\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3405\" class=\"ng-star-inserted\"\u003eEI-DVI Basic Model\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3423\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3423\"\u003eHeating Type\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3435\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3435\" class=\"ng-star-inserted\"\u003eElectrical Heating Block or Silicon Oil Bath\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3479\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3479\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3496\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3496\" class=\"ng-star-inserted\"\u003eTypically Ambient (2°C above Room Temp) up to 300°C\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3547\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3547\"\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3565\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3565\" class=\"ng-star-inserted\"\u003ePT-100 Platinum Resistance Sensor\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3598\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3598\"\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3620\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3620\" class=\"ng-star-inserted\"\u003eTypically 1°C (For basic model digital display)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3667\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3667\"\u003eTemperature Control\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3686\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3686\" class=\"ng-star-inserted\"\u003eDigital Controller with Energy Control Knob\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3729\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3729\"\u003eSample Viewing\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3743\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3743\" class=\"ng-star-inserted\"\u003eEyepiece with Magnifier and Illuminated Background\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3793\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3793\"\u003eCapillary Provision\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3812\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3812\" class=\"ng-star-inserted\"\u003eSamples accommodated in standard sealed capillary tubes\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3867\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3867\"\u003eAuxiliary Support\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3884\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3884\" class=\"ng-star-inserted\"\u003eProvision and clamp provided to fix one glass thermometer\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3941\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"3941\"\u003eStandard Heating Medium\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"3964\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"3964\" class=\"ng-star-inserted\"\u003eSilicon oil bath (Approx. 200 ml capacity)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"4006\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"4006\"\u003eStirring\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"4014\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"4014\" class=\"ng-star-inserted\"\u003eBuilt-in magnetic stirrer (if oil bath utilized)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ng-star-inserted\"\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"4062\"\u003e\u003cstrong class=\"ng-star-inserted\" data-start-index=\"4062\"\u003ePower Supply\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd class=\"ng-star-inserted\"\u003e\n\u003cdiv class=\"paragraph normal ng-star-inserted\" data-start-index=\"4074\"\u003e\u003cspan _ngcontent-ng-c1904016421=\"\" data-start-index=\"4074\" class=\"ng-star-inserted\"\u003eTypically AC 230 V ± 10%, 50 Hz\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51461015470326,"sku":"EI-MEL-DVI Basic","price":14750.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Melting_Point_Apparatus_-_DVI_Basic_Model_With_Digital_Temp._Controller__76644.1759897742.386.513.jpg?v=1786599178","url":"https:\/\/scispectrum.in\/products\/ei-dvi-basic-digital-melting-point-apparatus","provider":"SciSpectrum Lab Essentials","version":"1.0","type":"link"}