{"product_id":"eutech-pc2700-multi-parameter-benchtop-meter","title":"MULTI PARAMETER ECPC270043S PH\/Mv\/Ion\/Cond\/TDS\/Resist\/Salinity with Cond cell\/ph Glass  Electrode Dual Display Memory 500 \/RS232","description":"\u003cdiv class=\"powr-chat\" id=\"1abb102c_1753877895\"\u003e\u003c\/div\u003e\n\u003ch2\u003eMULTI PARAMETER ECPC270043S PH\u003c\/h2\u003e\n\u003ch2 id=\"product-features\"\u003eProduct Features\u003c\/h2\u003e\nYour all-in-one solution for multi-parameter research work in the lab! The new PC 2700 is accurate, reliable and intuitive with user-friendly functions. Meter comes with a multi-data screen that includes Temperature, electrode status, calibration points, date and time along with your desired measurement parameter. PC 2700 measures pH, ORP, ION, Conductivity, TDS, Salinity, or Resistivity!\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAdvanced Calibration\u003c\/strong\u003e - Choose auto-calibration with preset values for quick easy calibration, or manual multi-point calibration for greater accuracy MULTI PARAMETER ECPC270043S PH\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eEasy Standardization\u003c\/strong\u003e - Auto-standardization feature detects the exact cell constant value of your electrodes with the press of a button MULTI PARAMETER ECPC270043S PH\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eMulti-Point Calibration\u003c\/strong\u003e - Up to 6-point calibration with auto-buffer recognition\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eHigh Performance\u003c\/strong\u003e - Includes high performance 4-cell Conductivity probe\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eElectrode Diagnosis\u003c\/strong\u003e - Quick, easy electrode diagnosis with the effective cell constants display\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Storage\u003c\/strong\u003e - Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eData Transfer\u003c\/strong\u003e - Bi-directional RS232 for easy data transfer to computer\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCalibration Alarm\u003c\/strong\u003e - Cal-due alarm – no more out-dated calibrations! MULTI PARAMETER ECPC270043S PH\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eAuto-logging\u003c\/strong\u003e - Auto-logging function for convenient continuous monitoring\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eQuality Control\u003c\/strong\u003e - Limit alarm alerts when reading falls out of range\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003ePassword Protection\u003c\/strong\u003e - Password protection for setup and calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"applications\"\u003eApplications MULTI PARAMETER ECPC270043S PH\u003c\/h2\u003e\n\u003cdiv class=\"grid grid-cols-4 gap-4\"\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n \t\u003cli\u003eWater quality testing\u003c\/li\u003e\n \t\u003cli\u003eChecking metal finishes\u003c\/li\u003e\n \t\u003cli\u003eSolutions\u003c\/li\u003e\n \t\u003cli\u003eCooling tower water\u003c\/li\u003e\n \t\u003cli\u003eQuality assurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n \t\u003cli\u003ePrinting fountain solutions\u003c\/li\u003e\n \t\u003cli\u003eBoiler water\u003c\/li\u003e\n \t\u003cli\u003eBrines\u003c\/li\u003e\n \t\u003cli\u003eDrilling mud\u003c\/li\u003e\n \t\u003cli\u003eEcological studies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n \t\u003cli\u003eRinse tanks\u003c\/li\u003e\n \t\u003cli\u003ePonds\u003c\/li\u003e\n \t\u003cli\u003ePollution control\u003c\/li\u003e\n \t\u003cli\u003eRecirculating systems\u003c\/li\u003e\n \t\u003cli\u003eFood-processing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n \t\u003cli\u003eWaste water\u003c\/li\u003e\n \t\u003cli\u003eIndustrial process systems\u003c\/li\u003e\n \t\u003cli\u003eGeneral use in laboratories\u003c\/li\u003e\n \t\u003cli\u003eTitration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications MULTI PARAMETER ECPC270043S PH\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Specification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 \/ 0.01 \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.002 pH + 1 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCal. Points\u003c\/td\u003e\n\u003ctd\u003eUp to 6 preset or 5 custom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA, NIST, DIN, User 1, User 2, Custom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eORP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRel. mV Range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eION\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration\u003c\/td\u003e\n\u003ctd\u003e0.001 to 19999 ppm (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e2 or 3 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% full scale (monovalent);\n1% full scale (divalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCal. Points\u003c\/td\u003e\n\u003ctd\u003e2 to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.050 µS to 500.0 mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 \/ 0.1 µS ; 0.001 \/ 0.01 \/ 0.1 mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCal. Points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e0.010 to 10.000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.050 ppm to 500 ppt (@ TDS factor 1.00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 \/ 0.1 ppm ; 0.001 \/ 0.01 \/ 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCal. Points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0 to 80.0 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 \/ 0.1 ppm ; 0.001 \/ 0.01 \/ 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e2.000 Ohm to 20.0 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 \/ 0.1 Ohm ; 0.001 \/ 0.1 kOhm ; 0.01 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange (Meter)\u003c\/td\u003e\n\u003ctd\u003e0.0 to 100.0 ºC \/ 32.0 to 212.0 ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ºC \/ 0.1 ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 ºC \/ ±0.5 ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoefficient (Per ºC)\u003c\/td\u003e\n\u003ctd\u003eLinear \u0026amp; pure ; 0.000 to 10.000 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormalization\u003c\/td\u003e\n\u003ctd\u003e15.0 to 30.0 ºC \/ 59.0 to 86.0 ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensation\u003c\/td\u003e\n\u003ctd\u003eATC \/ MTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e9 V DC adapter, 1.3 A (100\/240 VAC, SMPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"order-information\"\u003e\u003c\/h2\u003e","brand":"Eutech","offers":[{"title":"Default Title","offer_id":51461008752886,"sku":"EUT-MTP-EC-PC-270043S","price":151040.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/eutech-instruments-ecpc270043s-desktop-ph-and-conductivity-composite-measuring-meter-2-20ph-2000-0-2000-0mv-pr53167-1__40349.1751975165.386.513_9a300953-6a70-4084-ada6-9571241fd28b.jpg?v=1786598964","url":"https:\/\/scispectrum.in\/products\/eutech-pc2700-multi-parameter-benchtop-meter","provider":"SciSpectrum Lab Essentials","version":"1.0","type":"link"}