{"product_id":"incubator-remi-rhi-50","title":"INCUBATOR REMI RHI-50 Hot air Incubator with 50 Liters capacity \u0026 Temperature setting range from RT + 5°C up to +65°C","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e\n    \/* SciSpectrum Color Scheme \u0026 Basics *\/\n    :root {\n        --primary-blue: #004a99;\n        --hover-blue: #0056b3;\n        --bg-gray: #f8f9fa;\n        --text-color: #333;\n        --border-color: #ddd;\n        --white: #ffffff;\n    }\n\n    body {\n        font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif;\n        line-height: 1.6;\n        color: var(--text-color);\n        background-color: var(--bg-gray);\n        margin: 0;\n        padding: 20px;\n    }\n\n    .scispectrum-tabs-container {\n        max-width: 1200px;\n        margin: 0 auto;\n        background: var(--white);\n        border-radius: 8px;\n        box-shadow: 0 4px 15px rgba(0,0,0,0.05);\n        overflow: hidden;\n    }\n\n    \/* Tab input handling *\/\n    .tab-input {\n        display: none;\n    }\n\n    \/* Tab navigation style *\/\n    .tab-nav {\n        display: flex;\n        flex-wrap: wrap;\n        border-bottom: 2px solid var(--border-color);\n        background-color: var(--white);\n    }\n\n    .tab-label {\n        padding: 15px 25px;\n        cursor: pointer;\n        font-weight: 600;\n        color: var(--primary-blue);\n        transition: all 0.3s ease;\n        border-bottom: 3px solid transparent;\n        text-align: center;\n        flex-grow: 1;\n    }\n\n    .tab-label:hover {\n        background-color: rgba(0, 74, 153, 0.05);\n        color: var(--hover-blue);\n    }\n\n    \/* Active tab styling *\/\n    #tab1:checked ~ .tab-nav label[for=\"tab1\"],\n    #tab2:checked ~ .tab-nav label[for=\"tab2\"],\n    #tab3:checked ~ .tab-nav label[for=\"tab3\"],\n    #tab4:checked ~ .tab-nav label[for=\"tab4\"] {\n        border-bottom-color: var(--primary-blue);\n        color: var(--primary-blue);\n        background-color: var(--white);\n    }\n\n    \/* Tab content panels *\/\n    .tab-panels {\n        padding: 30px;\n    }\n\n    .tab-content {\n        display: none;\n        animation: fadeIn 0.5s ease;\n    }\n\n    \/* Active panel handling *\/\n    #tab1:checked ~ .tab-panels #content1,\n    #tab2:checked ~ .tab-panels #content2,\n    #tab3:checked ~ .tab-panels #content3,\n    #tab4:checked ~ .tab-panels #content4 {\n        display: block;\n    }\n\n    @keyframes fadeIn {\n        from { opacity: 0; }\n        to { opacity: 1; }\n    }\n\n    \/* Utility Classes *\/\n    h3 { color: var(--primary-blue); margin-top: 0; }\n    \n    \/* Specifications Table Style *\/\n    .spec-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin-top: 20px;\n        font-size: 0.95rem;\n    }\n\n    .spec-table th, .spec-table td {\n        text-align: left;\n        padding: 12px 15px;\n        border-bottom: 1px solid var(--border-color);\n    }\n\n    .spec-table th {\n        background-color: var(--primary-blue);\n        color: var(--white);\n        text-transform: uppercase;\n        letter-spacing: 0.05em;\n    }\n\n    .spec-table tr:nth-child(even) {\n        background-color: rgba(0, 74, 153, 0.02);\n    }\n\n    .spec-table tr:hover {\n        background-color: rgba(0, 74, 153, 0.05);\n    }\n\n    \/* Features \u0026 Benefits List Style *\/\n    .features-list {\n        list-style: none;\n        padding: 0;\n        display: grid;\n        grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n        gap: 20px;\n    }\n\n    .features-list li {\n        background: var(--white);\n        padding: 20px;\n        border-radius: 6px;\n        border: 1px solid var(--border-color);\n        position: relative;\n        padding-left: 50px;\n        transition: transform 0.2s ease;\n    }\n    \n    .features-list li:hover {\n        transform: translateY(-3px);\n        box-shadow: 0 2px 10px rgba(0,0,0,0.05);\n    }\n\n    .features-list li::before {\n        content: '✓';\n        position: absolute;\n        left: 15px;\n        top: 20px;\n        color: var(--primary-blue);\n        font-weight: bold;\n        font-size: 1.2rem;\n    }\n\n    .feature-title {\n        font-weight: 700;\n        color: var(--primary-blue);\n        display: block;\n        margin-bottom: 5px;\n    }\n\n    \/* FAQ Style *\/\n    .faq-item {\n        margin-bottom: 25px;\n        border-bottom: 1px solid var(--border-color);\n        padding-bottom: 15px;\n    }\n\n    .faq-question {\n        font-weight: 600;\n        color: var(--primary-blue);\n        margin-bottom: 10px;\n        font-size: 1.1rem;\n    }\n\n    \/* Mobile Responsiveness *\/\n  @media (max-width: 768px) {\n    html, body {\n        padding: 0 !important;\n        margin: 0 !important;\n        width: 100%;\n        overflow-x: hidden;\n    }\n\n    .scispectrum-tabs-container {\n        width: 100% !important;\n        max-width: 100% !important;\n        margin: 0 !important;\n        border-radius: 0 !important;\n        box-shadow: none;\n    }\n\n    .tab-panels {\n        padding: 15px 8px !important;\n    }\n\n    .tab-label {\n        flex: 1 0 48%;\n        font-size: 0.85rem;\n        padding: 12px 2px;\n        box-sizing: border-box;\n    }\n\n    .faq-item {\n        margin: 0 0 15px 0 !important;\n        padding: 12px !important;\n        width: 100%;\n        box-sizing: border-box;\n    }\n}\n\u003c\/style\u003e\n\u003cdiv class=\"scispectrum-tabs-container\"\u003e\n\u003cinput id=\"tab1\" class=\"tab-input\" checked name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab2\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab3\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab4\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e\u003cnav class=\"tab-nav\"\u003e\u003clabel class=\"tab-label\" for=\"tab1\"\u003eOverview\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab2\"\u003eSpecifications\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab3\"\u003eFeatures \u0026amp; Benefits\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab4\"\u003eFAQs\u003c\/label\u003e\u003c\/nav\u003e\n\u003cdiv class=\"tab-panels\"\u003e\n\u003cdiv id=\"content1\" class=\"tab-content\"\u003e\n\u003ch3\u003eREMI RHI-50 Hot Air Incubator – Precision Laboratory Incubation System\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eREMI RHI-50 Hot Air Incubator\u003c\/strong\u003e is a high-performance laboratory incubation system engineered for precise thermal conditioning, microbiological incubation, sample stabilization, and diagnostic laboratory applications. Designed with advanced microprocessor-controlled technology, this 50-liter hot air incubator delivers highly stable temperature performance ranging from \u003cstrong\u003eRT +5°C to 65°C\u003c\/strong\u003e with outstanding \u003cstrong\u003e±0.5°C temperature stability\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBuilt for modern laboratories, research institutions, pharmaceutical facilities, educational laboratories, and diagnostic centers, the REMI RHI-50 combines \u003cstrong\u003eforced air convection heating\u003c\/strong\u003e with intelligent airflow distribution to ensure uniform temperature conditions throughout the stainless-steel chamber. Its polished stainless-steel interior with rounded corners enables fast cleaning, contamination control, and long-term durability.\u003c\/p\u003e\n\u003cp\u003eThe incubator features a \u003cstrong\u003emicroprocessor PID controller with timer functionality\u003c\/strong\u003e, enabling accurate process management for sensitive laboratory workflows. The integrated full inner glass door allows uninterrupted sample observation without disturbing internal temperature conditions, while the insulated external door improves thermal retention and energy efficiency.\u003c\/p\u003e\n\u003cp\u003eSafety-focused engineering includes self-diagnostic functions, over-temperature alarms, and temperature deviation alerts, ensuring reliable operation during critical laboratory testing procedures. The RHI-50 hot air incubator is widely used for microbiological incubation, culture growth, reagent conditioning, biochemical studies, environmental testing, and laboratory research requiring controlled heating environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content2\" class=\"tab-content\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter \/ Feature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot Air Incubator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eREMI RHI-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChamber Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRT +5°C to 65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForced Air Convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor PID Controller with Timer Function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Minute to 9999 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Chamber Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolished Stainless Steel with Rounded Corners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Dimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415 × 360 × 355 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Dimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 × 500 × 500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Shelves\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Adjustable Shelves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObservation Door\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull Inner Glass Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermally Insulated Outer Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-Diagnostic Function, Over Temperature Alarm, Temperature Difference Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220V, 50Hz, Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicrobiology, Diagnostics, Research Labs, Pharmaceutical Labs, Educational Institutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content3\" class=\"tab-content\"\u003e\n\u003ch3\u003eCore Features \u0026amp; User Benefits\u003c\/h3\u003e\n\u003cp\u003eThe REMI RHI-50 Hot Air Incubator is designed to deliver stable incubation conditions, operational safety, and laboratory efficiency for demanding scientific applications.\u003c\/p\u003e\n\u003cul class=\"features-list\"\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003ePrecise Temperature Stability\u003c\/span\u003e Achieve highly reliable incubation results with ±0.5°C temperature stability, reducing inconsistencies in microbiological cultures, diagnostic samples, and sensitive laboratory experiments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eMicroprocessor PID Temperature Control\u003c\/span\u003e The advanced PID controller continuously optimizes heating performance for accurate temperature maintenance and improved process repeatability in laboratory operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eEfficient Forced Air Convection\u003c\/span\u003e Uniform hot air circulation eliminates temperature gradients inside the chamber, ensuring consistent incubation conditions across all sample locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eDurable Stainless-Steel Chamber\u003c\/span\u003e The polished stainless-steel interior with rounded corners improves hygiene, corrosion resistance, contamination control, and cleaning convenience for routine laboratory use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eEnhanced Sample Visibility\u003c\/span\u003e The integrated full inner glass door enables safe monitoring of samples without opening the chamber, preserving temperature stability and minimizing heat loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eComprehensive Safety Protection\u003c\/span\u003e Built-in over-temperature alarms, temperature deviation alerts, and self-diagnostic systems help protect valuable samples and reduce operational risks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eFlexible Shelf Arrangement\u003c\/span\u003e Adjustable shelf spacing allows laboratories to accommodate different sample containers, culture plates, and laboratory vessels with maximum chamber utilization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eEnergy Efficient Thermal Insulation\u003c\/span\u003e The insulated outer door improves heat retention and operational efficiency while maintaining consistent incubation performance during extended testing cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content4\" class=\"tab-content\"\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat is the temperature range of the REMI RHI-50 Hot Air Incubator?\u003c\/p\u003e\n\u003cp\u003eThe REMI RHI-50 Hot Air Incubator provides a controlled temperature range from RT +5°C to 65°C, making it suitable for microbiology, diagnostic testing, pharmaceutical research, and laboratory incubation applications requiring stable thermal conditions and reliable heating performance.\u003c\/p\u003e\n\u003cp\u003eThe incubator uses a microprocessor PID controller combined with forced air convection technology to maintain precise and uniform chamber temperatures. This ensures dependable incubation results for bacterial culture growth, reagent conditioning, and scientific laboratory procedures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eHow accurate is the REMI RHI-50 laboratory incubator?\u003c\/p\u003e\n\u003cp\u003eThe REMI RHI-50 laboratory hot air incubator delivers excellent temperature stability of ±0.5°C with a display resolution of 0.1°C, helping laboratories achieve highly repeatable incubation conditions for research, diagnostics, and microbiological analysis.\u003c\/p\u003e\n\u003cp\u003eThe combination of PID-controlled heating and uniform air circulation minimizes temperature fluctuations within the chamber. This improves consistency for sensitive laboratory applications where stable thermal environments are essential.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat applications is the REMI RHI-50 Hot Air Incubator used for?\u003c\/p\u003e\n\u003cp\u003eThe REMI RHI-50 Hot Air Incubator is widely used in microbiology laboratories, pharmaceutical facilities, diagnostic centers, educational institutions, and research laboratories for sample incubation, bacterial culture growth, biochemical studies, and laboratory heating applications.\u003c\/p\u003e\n\u003cp\u003eIts stable temperature control, stainless-steel chamber, and forced air convection system make it ideal for scientific environments requiring controlled incubation and contamination-resistant chamber construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eDoes the REMI RHI-50 include safety protection features?\u003c\/p\u003e\n\u003cp\u003eYes, the REMI RHI-50 laboratory incubator includes multiple safety functions such as over-temperature alarms, temperature deviation alerts, and self-diagnostic systems to improve operational reliability and protect sensitive laboratory samples during incubation procedures.\u003c\/p\u003e\n\u003cp\u003eThese integrated safety features help laboratories quickly identify operational issues, reduce sample loss risks, and maintain safe working conditions during continuous incubation cycles.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhy is forced air convection important in a hot air incubator?\u003c\/p\u003e\n\u003cp\u003eForced air convection in the REMI RHI-50 Hot Air Incubator ensures even distribution of heated air throughout the chamber, improving temperature uniformity and reducing inconsistencies during microbiological incubation and laboratory testing procedures.\u003c\/p\u003e\n\u003cp\u003eThis airflow technology helps maintain stable thermal conditions across all shelf levels, improving repeatability and accuracy for scientific research, pharmaceutical testing, and laboratory culture applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Remi","offers":[{"title":"Default Title","offer_id":51460966383862,"sku":"REM-INC-RHI-50","price":77880.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/INCUBATOR_REMI_RHI-50_Hot_air_Incubator_with_50_Liters_capacity_Temperature_setting_range_from_RT_5C_up_to_65C__56899.1754846999.386.513_99f4f12f-2f34-481c-8aa7-422f6c6cd740.jpg?v=1786598932","url":"https:\/\/scispectrum.in\/products\/incubator-remi-rhi-50","provider":"SciSpectrum Lab Essentials","version":"1.0","type":"link"}