{"product_id":"jayant-j-94-ro-tap-sieve-shaker","title":"Jayant J-94 RO-TAP Sieve Shaker","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e \/* SciSpectrum Color Scheme \u0026 Basics *\/ :root { --primary-blue: #004a99; --hover-blue: #0056b3; --bg-gray: #f8f9fa; --text-color: #333; --border-color: #ddd; --white: #ffffff; }\nbody {\n    font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif;\n    line-height: 1.6;\n    color: var(--text-color);\n    background-color: var(--bg-gray);\n    margin: 0;\n    padding: 20px;\n}\n\n.scispectrum-tabs-container {\n    max-width: 1200px;\n    margin: 0 auto;\n    background: var(--white);\n    border-radius: 8px;\n    box-shadow: 0 4px 15px rgba(0,0,0,0.05);\n    overflow: hidden;\n}\n\n.tab-input {\n    display: none;\n}\n\n.tab-nav {\n    display: flex;\n    flex-wrap: wrap;\n    border-bottom: 2px solid var(--border-color);\n    background-color: var(--white);\n}\n\n.tab-label {\n    padding: 15px 25px;\n    cursor: pointer;\n    font-weight: 600;\n    color: var(--primary-blue);\n    transition: all 0.3s ease;\n    border-bottom: 3px solid transparent;\n    text-align: center;\n    flex-grow: 1;\n}\n\n.tab-label:hover {\n    background-color: rgba(0, 74, 153, 0.05);\n    color: var(--hover-blue);\n}\n\n#tab1:checked ~ .tab-nav label[for=\"tab1\"],\n#tab2:checked ~ .tab-nav label[for=\"tab2\"],\n#tab3:checked ~ .tab-nav label[for=\"tab3\"],\n#tab4:checked ~ .tab-nav label[for=\"tab4\"] {\n    border-bottom-color: var(--primary-blue);\n    color: var(--primary-blue);\n    background-color: var(--white);\n}\n\n.tab-panels {\n    padding: 30px;\n}\n\n.tab-content {\n    display: none;\n    animation: fadeIn 0.5s ease;\n}\n\n#tab1:checked ~ .tab-panels #content1,\n#tab2:checked ~ .tab-panels #content2,\n#tab3:checked ~ .tab-panels #content3,\n#tab4:checked ~ .tab-panels #content4 {\n    display: block;\n}\n\n@keyframes fadeIn {\n    from { opacity: 0; }\n    to { opacity: 1; }\n}\n\nh3 { color: var(--primary-blue); margin-top: 0; }\n\n.spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin-top: 20px;\n    font-size: 0.95rem;\n}\n\n.spec-table th, .spec-table td {\n    text-align: left;\n    padding: 12px 15px;\n    border-bottom: 1px solid var(--border-color);\n}\n\n.spec-table th {\n    background-color: var(--primary-blue);\n    color: var(--white);\n    text-transform: uppercase;\n    letter-spacing: 0.05em;\n}\n\n.spec-table tr:nth-child(even) {\n    background-color: rgba(0, 74, 153, 0.02);\n}\n\n.spec-table tr:hover {\n    background-color: rgba(0, 74, 153, 0.05);\n}\n\n.features-list {\n    list-style: none;\n    padding: 0;\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n    gap: 20px;\n}\n\n.features-list li {\n    background: var(--white);\n    padding: 20px;\n    border-radius: 6px;\n    border: 1px solid var(--border-color);\n    position: relative;\n    padding-left: 50px;\n    transition: transform 0.2s ease;\n}\n\n.features-list li:hover {\n    transform: translateY(-3px);\n    box-shadow: 0 2px 10px rgba(0,0,0,0.05);\n}\n\n.features-list li::before {\n    content: '✓';\n    position: absolute;\n    left: 15px;\n    top: 20px;\n    color: var(--primary-blue);\n    font-weight: bold;\n    font-size: 1.2rem;\n}\n\n.feature-title {\n    font-weight: 700;\n    color: var(--primary-blue);\n    display: block;\n    margin-bottom: 5px;\n}\n\n.faq-item {\n    margin-bottom: 25px;\n    border-bottom: 1px solid var(--border-color);\n    padding-bottom: 15px;\n}\n\n.faq-question {\n    font-weight: 600;\n    color: var(--primary-blue);\n    margin-bottom: 10px;\n    font-size: 1.1rem;\n}\n\n@media (max-width: 768px) {\n    html, body {\n        padding: 0 !important;\n        margin: 0 !important;\n        width: 100%;\n        overflow-x: hidden;\n    }\n\n    .scispectrum-tabs-container {\n        width: 100% !important;\n        max-width: 100% !important;\n        margin: 0 !important;\n        border-radius: 0 !important;\n        box-shadow: none;\n    }\n\n    .tab-panels {\n        padding: 15px 8px !important;\n    }\n\n    .tab-label {\n        flex: 1 0 48%;\n        font-size: 0.85rem;\n        padding: 12px 2px;\n        box-sizing: border-box;\n    }\n\n    .faq-item {\n        margin: 0 0 15px 0 !important;\n        padding: 12px !important;\n        width: 100%;\n        box-sizing: border-box;\n    }\n}\n\u003c\/style\u003e\n\u003cdiv class=\"scispectrum-tabs-container\"\u003e\n\u003cinput id=\"tab1\" class=\"tab-input\" checked name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab2\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab3\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab4\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e\u003cnav class=\"tab-nav\"\u003e\u003clabel class=\"tab-label\" for=\"tab1\"\u003eOverview\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab2\"\u003eSpecifications\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab3\"\u003eFeatures \u0026amp; Benefits\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab4\"\u003eFAQs\u003c\/label\u003e\u003c\/nav\u003e\n\u003cdiv class=\"tab-panels\"\u003e\n\u003cdiv id=\"content1\" class=\"tab-content\"\u003e\n\u003ch3\u003eJayant RO-TAP Sieve Shaker Model J-94 – Heavy Duty Floor Model Particle Size Analysis System\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eJAYANT Model J-94 RO-TAP Sieve Shaker\u003c\/strong\u003e is a precision-engineered heavy-duty laboratory instrument designed for accurate particle size analysis, dry sieving applications, and industrial quality control testing. Built for research laboratories, cement industries, mining operations, aggregate testing facilities, powder processing plants, pharmaceutical industries, and material testing laboratories, this advanced sieve shaker provides highly reproducible and consistent sieving performance for demanding laboratory environments.\u003c\/p\u003e\n\u003cp\u003eUtilizing a unique \u003cstrong\u003etwo-dimensional sieving mechanism\u003c\/strong\u003e, the J-94 combines horizontal circular oscillation with vertical tapping motion to ensure efficient material stratification and superior particle separation accuracy. This dual-action motion simulates highly controlled hand sieving while delivering repeatable analytical results essential for scientific testing and industrial quality assurance applications.\u003c\/p\u003e\n\u003cp\u003eThe RO-TAP mechanism is specifically developed for precise dry sieving of particles ranging from \u003cstrong\u003e25 mm down to 25 microns\u003c\/strong\u003e. Its advanced tapping and oscillation system enables particles to orient themselves efficiently and pass through critical sieve openings, improving test accuracy and reducing analysis time for fine powders, granular materials, aggregates, minerals, cement, soils, chemicals, and industrial raw materials.\u003c\/p\u003e\n\u003cp\u003eConstructed with a rugged industrial-grade framework, the Model J-94 is powered by an integrated \u003cstrong\u003e1\/4 H.P. electric motor\u003c\/strong\u003e designed for continuous heavy-duty operation. The machine accommodates up to \u003cstrong\u003e8 standard test sieves\u003c\/strong\u003e of 200 mm diameter and 50 mm height, making it suitable for high-volume laboratory testing workflows.\u003c\/p\u003e\n\u003cp\u003eThe internal drive system operates within specially lubricated machine oil to ensure smooth mechanical operation, reduced wear, and long operational life under intensive laboratory conditions. With controlled oscillation frequencies of 300–350 horizontal oscillations per minute and 180–200 tapping motions per minute, the J-94 ensures highly efficient particle classification and dependable repeatability.\u003c\/p\u003e\n\u003cp\u003eWidely used as professional laboratory testing equipment for particle grading, sieve analysis, industrial quality control, and research laboratory applications, the Jayant RO-TAP Sieve Shaker Model J-94 offers an ideal combination of mechanical durability, analytical precision, and long-term operational reliability for modern scientific and industrial laboratories.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content2\" class=\"tab-content\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRO-TAP Floor Model Sieve Shaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ-94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJAYANT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Dimensional Motion (Horizontal Circular + Vertical Tapping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSieving Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry Sieving Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParticle Analysis Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mm down to 25 Microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Sieve Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Sieves + Upper Lid + Bottom Receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Sieve Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Inches (200 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Sieve Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Inches (50 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHorizontal Oscillation Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 – 350 Oscillations per Minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOscillation Movement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\" x 0.85\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTapping Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 – 200 Taps per Minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 H.P. Built-In Electric Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 VAC, 50 Hz, 180 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Drive Lubrication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMachine Oil No. 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e640 x 560 x 950 mm (Approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 Kg Approx. (Without Sieves)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e215 Kg Approx. (With Wooden Case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain Sieve Shaker Unit Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal Timer Box with Mechanical Timer (10–60 Minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eParticle Size Analysis, Aggregate Testing, Soil Testing, Cement Testing, Powder Analysis, Industrial QC Laboratories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content3\" class=\"tab-content\"\u003e\n\u003ch3\u003eCore Features \u0026amp; User Benefits\u003c\/h3\u003e\n\u003cp\u003eThe JAYANT Model J-94 RO-TAP Sieve Shaker is engineered for highly accurate dry particle analysis with rugged industrial construction, repeatable sieving performance, and dependable laboratory operation.\u003c\/p\u003e\n\u003cul class=\"features-list\"\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eAdvanced RO-TAP Dual Motion Technology\u003c\/span\u003e Combines horizontal circular motion with vertical tapping action to ensure efficient material stratification and highly accurate particle separation results.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eHighly Reproducible Particle Analysis\u003c\/span\u003e The precision mechanical motion system delivers repeatable and dependable sieve analysis results for laboratory quality control and research applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eWide Particle Testing Range\u003c\/span\u003e Suitable for particle size analysis from 25 mm down to 25 microns, supporting both coarse and fine material testing applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eHeavy Duty Industrial Construction\u003c\/span\u003e Built with a rugged floor model structure and industrial-grade components designed for continuous laboratory and production environment use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eHigh Capacity Sieving System\u003c\/span\u003e Accommodates up to 8 test sieves simultaneously, improving laboratory throughput and testing efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003ePowerful Built-In Motor Assembly\u003c\/span\u003e Equipped with a reliable 1\/4 H.P. motor engineered for stable oscillation and tapping performance during continuous operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eEfficient Dry Sieving Performance\u003c\/span\u003e Specifically optimized for dry sieving applications requiring high accuracy in aggregate grading, mineral testing, powder analysis, and soil classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eControlled Oscillation and Tapping\u003c\/span\u003e Maintains precise oscillation and tapping frequencies for uniform material movement and improved analytical consistency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eLong Operational Life\u003c\/span\u003e Internal moving mechanisms operate within specialized lubricating oil to minimize wear and ensure smooth long-term operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eSuitable for Multiple Industries\u003c\/span\u003e Ideal laboratory testing equipment for cement plants, mining industries, pharmaceuticals, aggregate laboratories, research institutes, and industrial quality control facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content4\" class=\"tab-content\"\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat is the primary application of the Jayant J-94 RO-TAP Sieve Shaker?\u003c\/p\u003e\n\u003cp\u003eThe Jayant J-94 RO-TAP Sieve Shaker is primarily used for accurate dry particle size analysis in laboratories and industrial quality control environments. Its dual-motion sieving mechanism ensures highly reproducible particle separation for aggregates, powders, minerals, cement, soil, and granular material testing applications.\u003c\/p\u003e\n\u003cp\u003eThis laboratory testing equipment is widely used in research laboratories, mining industries, cement plants, pharmaceuticals, construction material testing facilities, and industrial quality assurance departments requiring precise sieve analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eHow does the RO-TAP dual motion system improve sieve analysis accuracy?\u003c\/p\u003e\n\u003cp\u003eThe RO-TAP mechanism combines horizontal circular oscillation with vertical tapping motion to improve material stratification and particle movement across the sieve surface. This dual-action system enables particles to efficiently seek critical openings, improving separation accuracy and delivering consistent particle size distribution results.\u003c\/p\u003e\n\u003cp\u003eThe mechanized sieving action closely simulates controlled hand sieving while providing significantly better repeatability and reduced operator variability during testing procedures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eHow many sieves can be accommodated in the J-94 Sieve Shaker?\u003c\/p\u003e\n\u003cp\u003eThe Jayant J-94 RO-TAP Sieve Shaker can accommodate a maximum of 8 standard test sieves along with an upper lid and bottom receiver assembly. The machine is specifically designed for 200 mm diameter and 50 mm height laboratory test sieves.\u003c\/p\u003e\n\u003cp\u003eThis large sieve holding capacity improves laboratory productivity by allowing multiple particle grading stages to be analyzed simultaneously during a single sieving cycle.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eIs the J-94 suitable for wet sieving applications?\u003c\/p\u003e\n\u003cp\u003eNo, the Jayant Model J-94 RO-TAP Sieve Shaker is specifically designed for dry sieving applications only. It is optimized for accurate dry particle size analysis of powders, aggregates, soils, minerals, chemicals, and industrial raw materials.\u003c\/p\u003e\n\u003cp\u003eIts controlled oscillation and tapping mechanism ensure dependable dry material stratification and efficient passage through test sieve openings without moisture-related interference.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat optional accessories are available with the J-94 RO-TAP Sieve Shaker?\u003c\/p\u003e\n\u003cp\u003eAn optional external timer box is available for the J-94 RO-TAP Sieve Shaker to automate sieving duration control. The timer unit includes an ON\/OFF switch, pilot lamp, 3-pin socket, and imported mechanical timer with a 10 to 60-minute setting range.\u003c\/p\u003e\n\u003cp\u003eThis accessory improves operational convenience, enhances repeatability, and supports standardized laboratory testing procedures for routine particle analysis applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e { \"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [ { \"@type\": \"Question\", \"name\": \"What is the primary application of the Jayant J-94 RO-TAP Sieve Shaker?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"The Jayant J-94 RO-TAP Sieve Shaker is primarily used for accurate dry particle size analysis in laboratories and industrial quality control environments. Its dual-motion sieving mechanism ensures highly reproducible particle separation for aggregates, powders, minerals, cement, soil, and granular material testing applications. This laboratory testing equipment is widely used in research laboratories, mining industries, cement plants, pharmaceuticals, construction material testing facilities, and industrial quality assurance departments requiring precise sieve analysis.\" } }, { \"@type\": \"Question\", \"name\": \"How does the RO-TAP dual motion system improve sieve analysis accuracy?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"The RO-TAP mechanism combines horizontal circular oscillation with vertical tapping motion to improve material stratification and particle movement across the sieve surface. This dual-action system enables particles to efficiently seek critical openings, improving separation accuracy and delivering consistent particle size distribution results. The mechanized sieving action closely simulates controlled hand sieving while providing significantly better repeatability and reduced operator variability during testing procedures.\" } }, { \"@type\": \"Question\", \"name\": \"How many sieves can be accommodated in the J-94 Sieve Shaker?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"The Jayant J-94 RO-TAP Sieve Shaker can accommodate a maximum of 8 standard test sieves along with an upper lid and bottom receiver assembly. The machine is specifically designed for 200 mm diameter and 50 mm height laboratory test sieves. This large sieve holding capacity improves laboratory productivity by allowing multiple particle grading stages to be analyzed simultaneously during a single sieving cycle.\" } }, { \"@type\": \"Question\", \"name\": \"Is the J-94 suitable for wet sieving applications?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"No, the Jayant Model J-94 RO-TAP Sieve Shaker is specifically designed for dry sieving applications only. It is optimized for accurate dry particle size analysis of powders, aggregates, soils, minerals, chemicals, and industrial raw materials. Its controlled oscillation and tapping mechanism ensure dependable dry material stratification and efficient passage through test sieve openings without moisture-related interference.\" } }, { \"@type\": \"Question\", \"name\": \"What optional accessories are available with the J-94 RO-TAP Sieve Shaker?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"An optional external timer box is available for the J-94 RO-TAP Sieve Shaker to automate sieving duration control. The timer unit includes an ON\/OFF switch, pilot lamp, 3-pin socket, and imported mechanical timer with a 10 to 60-minute setting range. This accessory improves operational convenience, enhances repeatability, and supports standardized laboratory testing procedures for routine particle analysis applications.\" } } ] } \u003c\/script\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Jayant","offers":[{"title":"Default Title","offer_id":51460978704630,"sku":"JAY-SHK-J-94","price":113870.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/JAYANT_RO_TAP_SIEVE_SHAKER_MODEL_J-94___37386.1760360802.386.513.png?v=1786599272","url":"https:\/\/scispectrum.in\/products\/jayant-j-94-ro-tap-sieve-shaker","provider":"SciSpectrum Lab Essentials","version":"1.0","type":"link"}