{"product_id":"microprocessor-based-ec-tds-sal-meter-model-1602-conductivity-salinity-temperature","title":"Microprocessor Based EC-TDS-Sal Meter Model 1602 | Conductivity, Salinity \u0026 Temperature","description":"\u003cstyle\u003e\n    \/* SciSpectrum Color Scheme \u0026 Basics *\/\n    :root {\n        --primary-blue: #004a99;\n        --hover-blue: #0056b3;\n        --bg-gray: #f8f9fa;\n        --text-color: #333;\n        --border-color: #ddd;\n        --white: #ffffff;\n    }\n\n    .scispectrum-tabs-container {\n        max-width: 1200px;\n        margin: 0 auto;\n        background: var(--white);\n        border-radius: 8px;\n        box-shadow: 0 4px 15px rgba(0,0,0,0.05);\n        overflow: hidden;\n        font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif;\n        line-height: 1.6;\n        color: var(--text-color);\n    }\n\n    \/* Tab input handling *\/\n    .tab-input {\n        display: none;\n    }\n\n    \/* Tab navigation style *\/\n    .tab-nav {\n        display: flex;\n        flex-wrap: wrap;\n        border-bottom: 2px solid var(--border-color);\n        background-color: var(--white);\n    }\n\n    .tab-label {\n        padding: 15px 25px;\n        cursor: pointer;\n        font-weight: 600;\n        color: var(--primary-blue);\n        transition: all 0.3s ease;\n        border-bottom: 3px solid transparent;\n        text-align: center;\n        flex-grow: 1;\n    }\n\n    .tab-label:hover {\n        background-color: rgba(0, 74, 153, 0.05);\n        color: var(--hover-blue);\n    }\n\n    \/* Active tab styling *\/\n    #tab1:checked ~ .tab-nav label[for=\"tab1\"],\n    #tab2:checked ~ .tab-nav label[for=\"tab2\"],\n    #tab3:checked ~ .tab-nav label[for=\"tab3\"],\n    #tab4:checked ~ .tab-nav label[for=\"tab4\"] {\n        border-bottom-color: var(--primary-blue);\n        color: var(--primary-blue);\n        background-color: var(--white);\n    }\n\n    \/* Tab content panels *\/\n    .tab-panels {\n        padding: 30px;\n    }\n\n    .tab-content {\n        display: none;\n        animation: fadeIn 0.5s ease;\n    }\n\n    \/* Active panel handling *\/\n    #tab1:checked ~ .tab-panels #content1,\n    #tab2:checked ~ .tab-panels #content2,\n    #tab3:checked ~ .tab-panels #content3,\n    #tab4:checked ~ .tab-panels #content4 {\n        display: block;\n    }\n\n    @keyframes fadeIn {\n        from { opacity: 0; }\n        to { opacity: 1; }\n    }\n\n    \/* Utility Classes *\/\n    .tab-panels h3 { color: var(--primary-blue); margin-top: 0; font-size: 1.4rem; }\n    \n    \/* Specifications Table Style *\/\n    .spec-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin-top: 20px;\n        font-size: 0.95rem;\n    }\n\n    .spec-table th, .spec-table td {\n        text-align: left;\n        padding: 12px 15px;\n        border-bottom: 1px solid var(--border-color);\n    }\n\n    .spec-table th {\n        background-color: var(--primary-blue);\n        color: var(--white);\n        text-transform: uppercase;\n        letter-spacing: 0.05em;\n    }\n\n    .spec-table tr:nth-child(even) {\n        background-color: rgba(0, 74, 153, 0.02);\n    }\n\n    .spec-table tr:hover {\n        background-color: rgba(0, 74, 153, 0.05);\n    }\n\n    \/* Features \u0026 Benefits List Style *\/\n    .features-list {\n        list-style: none;\n        padding: 0;\n        display: grid;\n        grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n        gap: 20px;\n    }\n\n    .features-list li {\n        background: var(--white);\n        padding: 20px;\n        border-radius: 6px;\n        border: 1px solid var(--border-color);\n        position: relative;\n        padding-left: 50px;\n        transition: transform 0.2s ease;\n    }\n    \n    .features-list li:hover {\n        transform: translateY(-3px);\n        box-shadow: 0 2px 10px rgba(0,0,0,0.05);\n    }\n\n    .features-list li::before {\n        content: '✓';\n        position: absolute;\n        left: 15px;\n        top: 20px;\n        color: var(--primary-blue);\n        font-weight: bold;\n        font-size: 1.2rem;\n    }\n\n    .feature-title {\n        font-weight: 700;\n        color: var(--primary-blue);\n        display: block;\n        margin-bottom: 5px;\n    }\n\n    \/* FAQ Style *\/\n    .faq-item {\n        margin-bottom: 25px;\n        border-bottom: 1px solid var(--border-color);\n        padding-bottom: 15px;\n    }\n\n    .faq-question {\n        font-weight: 600;\n        color: var(--primary-blue);\n        margin-bottom: 10px;\n        font-size: 1.1rem;\n    }\n\n    \/* Mobile Responsiveness *\/\n    @media (max-width: 768px) {\n        .scispectrum-tabs-container {\n            width: 100% !important;\n            max-width: 100% !important;\n            margin: 0 !important;\n            border-radius: 0 !important;\n            box-shadow: none;\n        }\n\n        .tab-panels {\n            padding: 15px 8px !important;\n        }\n\n        .tab-label {\n            flex: 1 0 48%;\n            font-size: 0.85rem;\n            padding: 12px 2px;\n            box-sizing: border-box;\n        }\n\n        .faq-item {\n            margin: 0 0 15px 0 !important;\n            padding: 12px !important;\n            width: 100%;\n            box-sizing: border-box;\n        }\n    }\n\u003c\/style\u003e\n\u003cdiv class=\"scispectrum-tabs-container\"\u003e\n\u003cinput id=\"tab1\" class=\"tab-input\" checked name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab2\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab3\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab4\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e\u003cnav class=\"tab-nav\"\u003e\u003clabel class=\"tab-label\" for=\"tab1\"\u003eOverview\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab2\"\u003eSpecifications\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab3\"\u003eFeatures \u0026amp; Benefits\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab4\"\u003eFAQs\u003c\/label\u003e\u003c\/nav\u003e\n\u003cdiv class=\"tab-panels\"\u003e\n\u003cdiv id=\"content1\" class=\"tab-content\"\u003e\n\u003ch3\u003eModel 1602 Microprocessor Based EC-TDS-Sal Meter – Multi-Parameter Water Quality Analysis System\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eModel 1602 Microprocessor Based EC-TDS-Sal Meter\u003c\/strong\u003e is an advanced, solid-state laboratory instrument engineered for the simultaneous, high-precision measurement of Electrical Conductivity (EC), Total Dissolved Solids (TDS), Salinity, and Temperature. By incorporating state-of-the-art microprocessor architecture, this versatile analytical meter minimizes operational variance while ensuring maximum reproducibility and absolute accuracy for critical environmental, industrial, and quality control procedures.\u003c\/p\u003e\n\u003cp\u003eDesigned to meet the rigorous demands of modern laboratory workflows, the Model 1602 features an intuitive user interface powered by interactive system prompts. These real-time prompts seamlessly guide operators through step-by-step optimization routines and calibration curves. The instrument displays technical parameters on an integrated 128 x 64 dots Graphical LCD Display, complemented by an ergonomic 8-key soft-touch membrane keypad built for prolonged operational durability.\u003c\/p\u003e\n\u003cp\u003eTo eliminate manual range alignment errors, the meter implements a sophisticated Auto Ranging Facility across all chemical concentration bounds. Coupled with an advanced Automatic Temperature Compensation (ATC) system, adjustable cell constants ranging from 0.05 to 10.5, and a programmable temperature coefficient, the Model 1602 guarantees absolute mathematical correction across shifting chemical solutions.\u003c\/p\u003e\n\u003cp\u003eFor data management compliance, the platform provides a substantial non-volatile storage matrix capable of holding up to 1000 logged samples. These values remain securely written within internal storage arrays even during total power failures. External logging interfaces are managed via an integrated RS-232 serial printer interface, allowing seamless data transfers to thermal recording systems or standard 80-column Dot Matrix Printers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content2\" class=\"tab-content\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter \/ Feature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor Based EC-TDS-Salinity-Temp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModel 1602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Conductivity (EC), TDS, Salinity, Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity (EC) Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-20 µS, 0-200 µS, 0-2 mS, 0-20 mS, 0-200 mS (Auto Ranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-20 ppm, 0-200 ppm, 0-2 ppt, 0-20 ppt, 0-200 ppt (Auto Ranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-20 ppm, 0-200 ppm, 0-2 ppt, 0-20 ppt, 0-50 ppt (Auto Ranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 – 100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEC: ±0.5% FS ±1 Digit | TDS \u0026amp; Salinity: ±1% FS ±1 Digit | Temp: ±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 µS (EC) | 0.01 ppm (TDS\/Sal) | 0.1 °C (Temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCell Constant Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable from 0.05 to 10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic \/ Manual (Range: 0 – 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable \/ Adjustable from 0.1% to 4.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVisual Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 x 64 dots Graphical LCD Display Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging Matrix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal storage for up to 1000 analytical samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 soft-touch membrane type keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Connectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232 serial printer port (Supports 80-column Dot Matrix or Thermal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V DC via a regulated 230V ±10% AC Adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 x 202 x 80 mm (Approximate Case Footprint)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Instrument Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 Kg (Approximate Solid-State Housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Accessories Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEC\/TDS Cell (Constant ~1.00), Temperature Probe, Electrode Stand, Mains Lead, Dust Cover, Instruction Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content3\" class=\"tab-content\"\u003e\n\u003ch3\u003eCore Features \u0026amp; User Benefits\u003c\/h3\u003e\n\u003cul class=\"features-list\"\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eAdvanced Microprocessor Engineering\u003c\/span\u003e Utilizes state-of-the-art computational chips to maximize accuracy, speed up stabilization timelines, and deliver high repeatability during critical laboratory screenings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eSmart Auto Ranging Facility\u003c\/span\u003e Automatically matches specific chemical concentration bounds across EC, TDS, and Salinity scales, reducing user setup errors and simplifying manual procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eAutomatic Temperature Compensation (ATC)\u003c\/span\u003e Employs real-time solution scaling via an adjustable temperature coefficient (0.1–4.0%) and programmable baseline matrix to eliminate thermal reading drift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eMassive 1000-Sample Data Memory\u003c\/span\u003e Incorporates high-capacity non-volatile internal data storage that keeps recorded batches secure and organized even through unexpected power shutdowns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eHigh-Resolution Graphical LCD Display\u003c\/span\u003e Integrates a highly readable 128 x 64 dots graphical workspace, complete with responsive on-screen operational prompt tracks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eDirect RS-232 Printer Connectivity\u003c\/span\u003e Eliminates transcription errors with direct serial outputs, sending logged datasets to external thermal hardware or classic 80-column dot matrix printers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eFully Scalable Adjustments\u003c\/span\u003e Supports extensive cell constant modifications from 0.05 to 10.5, allowing users to adapt the system to specific water assessment applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eIndustrial Grade Membrane Keypad\u003c\/span\u003e Features 8 durable, wipe-clean soft-touch keys that prevent fluid ingress and maintain tactile feedback in harsh environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content4\" class=\"tab-content\"\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat parameters can the Model 1602 Microprocessor Meter analyze simultaneously?\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eModel 1602 Microprocessor EC-TDS-Sal Meter\u003c\/strong\u003e performs high-precision measurements of Electrical Conductivity (EC), Total Dissolved Solids (TDS), Salinity, and Temperature. It functions as a consolidated analytical platform for water quality assessment across chemical processing and industrial testing facilities.\u003c\/p\u003e\n\u003cp\u003eBy streamlining multi-tier data processing onto a single processing core, laboratories can eliminate the footprint and expense of separate, single-parameter benches.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eHow does the Auto Ranging Facility on the Model 1602 improve user accuracy?\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eModel 1602 Microprocessor EC-TDS-Sal Meter\u003c\/strong\u003e features an automated Auto Ranging Facility that dynamically adjusts scale selection across solution concentrations. This technical framework eliminates manual switching errors and guarantees optimal display resolution throughout variable fluid testing profiles.\u003c\/p\u003e\n\u003cp\u003eIt protects against measurement over-range issues when moving between highly pure water samples and ultra-concentrated saline fluids.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWill stored test results be lost if the water testing meter loses power?\u003c\/p\u003e\n\u003cp\u003eNo, the \u003cstrong\u003eModel 1602 Microprocessor EC-TDS-Sal Meter\u003c\/strong\u003e stores up to 1000 samples inside non-volatile memory chips. Stored analytical matrices are reliably retained when the system is powered down or disconnected from standard AC adapters.\u003c\/p\u003e\n\u003cp\u003eThis design prevents field data loss during power fluctuations, maintaining secure logging structures for high-volume research and quality control applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat are the specific temperature compensation options available on this meter?\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eModel 1602 Microprocessor EC-TDS-Sal Meter\u003c\/strong\u003e provides advanced Automatic Temperature Compensation (ATC) and manual modes spanning 0 to 50°C. Operators can configure a programmable reference temperature alongside custom temperature coefficient bounds from 0.1% to 4.0%.\u003c\/p\u003e\n\u003cp\u003eThis deep compensation framework is ideal for adjusting raw conductivity variables when evaluating warm industrial effluents or boiler feed inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eHow does the integrated data logging system connect with external data management networks?\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eModel 1602 Microprocessor EC-TDS-Sal Meter\u003c\/strong\u003e connects to validation networks via an onboard serial RS-232 printing interface port. This link allows direct physical output generation to 80-column Dot Matrix or thermal recording accessories.\u003c\/p\u003e\n\u003cp\u003eThis hard-wired loop helps quality assurance managers maintain clean data records for pharmaceutical compliance audits and municipal water checks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51460973756662,"sku":"EI-DVI-TDS-1602","price":43542.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/EI-DVI-Microprocessor-Based-Conductivity-model-1602-TDS-sal-Meter-2__10915.1760606426.386.513.jpg?v=1786599138","url":"https:\/\/scispectrum.in\/products\/microprocessor-based-ec-tds-sal-meter-model-1602-conductivity-salinity-temperature","provider":"SciSpectrum Lab Essentials","version":"1.0","type":"link"}