{"product_id":"model-918-electromagnetic-sieve-shaker","title":"Model 918 Electromagnetic Sieve Shaker","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e\n    \/* SciSpectrum Color Scheme \u0026 Basics *\/\n    :root {\n        --primary-blue: #004a99;\n        --hover-blue: #0056b3;\n        --bg-gray: #f8f9fa;\n        --text-color: #333;\n        --border-color: #ddd;\n        --white: #ffffff;\n    }\n\n    body {\n        font-family: 'Segoe UI', Tahoma, Geneva, Verdana, sans-serif;\n        line-height: 1.6;\n        color: var(--text-color);\n        background-color: var(--bg-gray);\n        margin: 0;\n        padding: 20px;\n    }\n\n    .scispectrum-tabs-container {\n        max-width: 1200px;\n        margin: 0 auto;\n        background: var(--white);\n        border-radius: 8px;\n        box-shadow: 0 4px 15px rgba(0,0,0,0.05);\n        overflow: hidden;\n    }\n\n    .tab-input {\n        display: none;\n    }\n\n    .tab-nav {\n        display: flex;\n        flex-wrap: wrap;\n        border-bottom: 2px solid var(--border-color);\n        background-color: var(--white);\n    }\n\n    .tab-label {\n        padding: 15px 25px;\n        cursor: pointer;\n        font-weight: 600;\n        color: var(--primary-blue);\n        transition: all 0.3s ease;\n        border-bottom: 3px solid transparent;\n        text-align: center;\n        flex-grow: 1;\n    }\n\n    .tab-label:hover {\n        background-color: rgba(0, 74, 153, 0.05);\n        color: var(--hover-blue);\n    }\n\n    #tab1:checked ~ .tab-nav label[for=\"tab1\"],\n    #tab2:checked ~ .tab-nav label[for=\"tab2\"],\n    #tab3:checked ~ .tab-nav label[for=\"tab3\"],\n    #tab4:checked ~ .tab-nav label[for=\"tab4\"] {\n        border-bottom-color: var(--primary-blue);\n        color: var(--primary-blue);\n        background-color: var(--white);\n    }\n\n    .tab-panels {\n        padding: 30px;\n    }\n\n    .tab-content {\n        display: none;\n        animation: fadeIn 0.5s ease;\n    }\n\n    #tab1:checked ~ .tab-panels #content1,\n    #tab2:checked ~ .tab-panels #content2,\n    #tab3:checked ~ .tab-panels #content3,\n    #tab4:checked ~ .tab-panels #content4 {\n        display: block;\n    }\n\n    @keyframes fadeIn {\n        from { opacity: 0; }\n        to { opacity: 1; }\n    }\n\n    h3 { color: var(--primary-blue); margin-top: 0; }\n\n    .spec-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin-top: 20px;\n        font-size: 0.95rem;\n    }\n\n    .spec-table th, .spec-table td {\n        text-align: left;\n        padding: 12px 15px;\n        border-bottom: 1px solid var(--border-color);\n    }\n\n    .spec-table th {\n        background-color: var(--primary-blue);\n        color: var(--white);\n        text-transform: uppercase;\n        letter-spacing: 0.05em;\n    }\n\n    .spec-table tr:nth-child(even) {\n        background-color: rgba(0, 74, 153, 0.02);\n    }\n\n    .spec-table tr:hover {\n        background-color: rgba(0, 74, 153, 0.05);\n    }\n\n    .features-list {\n        list-style: none;\n        padding: 0;\n        display: grid;\n        grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n        gap: 20px;\n    }\n\n    .features-list li {\n        background: var(--white);\n        padding: 20px;\n        border-radius: 6px;\n        border: 1px solid var(--border-color);\n        position: relative;\n        padding-left: 50px;\n        transition: transform 0.2s ease;\n    }\n\n    .features-list li:hover {\n        transform: translateY(-3px);\n        box-shadow: 0 2px 10px rgba(0,0,0,0.05);\n    }\n\n    .features-list li::before {\n        content: '✓';\n        position: absolute;\n        left: 15px;\n        top: 20px;\n        color: var(--primary-blue);\n        font-weight: bold;\n        font-size: 1.2rem;\n    }\n\n    .feature-title {\n        font-weight: 700;\n        color: var(--primary-blue);\n        display: block;\n        margin-bottom: 5px;\n    }\n\n    .faq-item {\n        margin-bottom: 25px;\n        border-bottom: 1px solid var(--border-color);\n        padding-bottom: 15px;\n    }\n\n    .faq-question {\n        font-weight: 600;\n        color: var(--primary-blue);\n        margin-bottom: 10px;\n        font-size: 1.1rem;\n    }\n\n    @media (max-width: 768px) {\n        html, body {\n            padding: 0 !important;\n            margin: 0 !important;\n            width: 100%;\n            overflow-x: hidden;\n        }\n\n        .scispectrum-tabs-container {\n            width: 100% !important;\n            max-width: 100% !important;\n            margin: 0 !important;\n            border-radius: 0 !important;\n            box-shadow: none;\n        }\n\n        .tab-panels {\n            padding: 15px 8px !important;\n        }\n\n        .tab-label {\n            flex: 1 0 48%;\n            font-size: 0.85rem;\n            padding: 12px 2px;\n            box-sizing: border-box;\n        }\n\n        .faq-item {\n            margin: 0 0 15px 0 !important;\n            padding: 12px !important;\n            width: 100%;\n            box-sizing: border-box;\n        }\n    }\n\u003c\/style\u003e\n\u003cdiv class=\"scispectrum-tabs-container\"\u003e\n\u003cinput id=\"tab1\" class=\"tab-input\" checked name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab2\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab3\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e \u003cinput id=\"tab4\" class=\"tab-input\" name=\"scispectrum-tabs\" type=\"radio\"\u003e\u003cnav class=\"tab-nav\"\u003e\u003clabel class=\"tab-label\" for=\"tab1\"\u003eOverview\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab2\"\u003eSpecifications\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab3\"\u003eFeatures \u0026amp; Benefits\u003c\/label\u003e \u003clabel class=\"tab-label\" for=\"tab4\"\u003eFAQs\u003c\/label\u003e\u003c\/nav\u003e\n\u003cdiv class=\"tab-panels\"\u003e\n\u003cdiv id=\"content1\" class=\"tab-content\"\u003e\n\u003ch3\u003eEI Model 918 Electromagnetic Sieve Shaker – High Precision Particle Size Analysis System\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEI Model 918 Electromagnetic Sieve Shaker\u003c\/strong\u003e is a precision-engineered laboratory testing instrument designed for highly accurate particle size separation and grading applications in research laboratories, industrial quality control departments, pharmaceutical facilities, mining laboratories, construction material testing laboratories, food industries, and scientific research environments. Manufactured by \u003cstrong\u003eElectronics India (EI)\u003c\/strong\u003e, this advanced electromagnetic sieve shaker delivers reliable and reproducible sieving performance for dry particle analysis and production quality monitoring.\u003c\/p\u003e\n\u003cp\u003eBuilt using advanced electromagnetic drive technology, the Model 918 generates powerful and precisely controlled electromagnetic impulses that ensure efficient particle movement through the sieve stack. This sophisticated operation allows laboratories to achieve highly repeatable and sharp particle separation even for fine materials requiring superior analytical precision. The programmable electromagnetic power system enables accurate adjustment of vibration intensity according to different sample characteristics, improving test consistency and reducing analysis time.\u003c\/p\u003e\n\u003cp\u003eThe instrument features a robust and durable laboratory-grade construction specifically designed for continual and intensive operation in demanding industrial and scientific environments. The system supports up to \u003cstrong\u003e8 standard 200 mm test sieves\u003c\/strong\u003e, allowing simultaneous multi-level particle separation for efficient laboratory throughput and production quality assessment.\u003c\/p\u003e\n\u003cp\u003eThe Model 918 incorporates a user-friendly digital operating interface with a \u003cstrong\u003e20 x 4 alphanumeric backlit LCD display\u003c\/strong\u003e and fully alphanumeric keypad for convenient parameter programming and operational monitoring. Laboratories can precisely program shake durations from 1 to 99 minutes while selecting electromagnetic power levels from 1 to 20 to optimize sieving efficiency for various materials and mesh sizes.\u003c\/p\u003e\n\u003cp\u003eDesigned for modern laboratory automation and secure operational control, the sieve shaker includes both intermittent and continuous shifting motion modes, two-tier password protection for administrator and user-level security, and an RS232 communication port for connection to serial printers. Its very low-noise electromagnetic design further improves laboratory comfort during continuous operation.\u003c\/p\u003e\n\u003cp\u003eWidely used for particle size distribution analysis, powder testing, soil analysis, pharmaceutical granule evaluation, cement testing, aggregate analysis, food powder grading, and industrial material classification, the EI Model 918 Electromagnetic Sieve Shaker offers an ideal balance of precision, operational flexibility, and dependable long-term laboratory performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content2\" class=\"tab-content\"\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter \/ Feature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromagnetic Sieve Shaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e918\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEI (Electronics India)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntermittent and Continuous Shifting Motion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntermittent Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 Second Intervals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSieve Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 8 Sieves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Sieve Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mm Diameter x 50 mm Height Test Sieves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShake Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable from 1 Minute to 99 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable Electromagnetic Power from 1 to 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 x 4 Alphanumeric LCD with Backlit Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeypad\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully Alphanumeric Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVery Low Noise Operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Tier Password Protection (Admin \u0026amp; User)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrinter Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 Port for Serial Printer Connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrinter Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 Column Dot Matrix or Thermal Printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSieving Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry Sieving Standard (Wet Sieving Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220V AC, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x B x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 mm x 390 mm x 260 mm (Approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 Kg Approx. (Without Sieves)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eParticle Size Analysis, Powder Testing, Soil Analysis, Pharmaceutical QC, Cement Testing, Aggregate Analysis, Industrial Material Classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content3\" class=\"tab-content\"\u003e\n\u003ch3\u003eCore Features \u0026amp; User Benefits\u003c\/h3\u003e\n\u003cp\u003eThe EI Model 918 Electromagnetic Sieve Shaker is engineered for highly accurate particle size analysis with advanced electromagnetic control, programmable operation, and dependable laboratory performance.\u003c\/p\u003e\n\u003cul class=\"features-list\"\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eAdvanced Electromagnetic Drive Technology\u003c\/span\u003e Powerful electromagnetic impulses provide highly consistent and repeatable sieve agitation for accurate particle size separation and improved analytical reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eHigh Precision Fine Particle Sieving\u003c\/span\u003e The controllable vibration system enables sharp particle fraction separation even for fine powders and difficult materials requiring superior analytical precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eProgrammable Power Control\u003c\/span\u003e Adjustable electromagnetic power levels from 1 to 20 allow laboratories to optimize shaking intensity according to sample density and mesh characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eDual Shaking Motion Modes\u003c\/span\u003e Supports both intermittent and continuous shifting motion for flexible adaptation to various laboratory testing requirements and material properties.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eLarge Multi-Sieve Capacity\u003c\/span\u003e Accommodates up to 8 standard test sieves simultaneously, improving laboratory productivity and reducing overall testing time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eUser-Friendly Digital Interface\u003c\/span\u003e The large backlit LCD display and fully alphanumeric keypad simplify programming, operation, and monitoring during routine laboratory testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eSecure Password Protection System\u003c\/span\u003e Two-tier admin and user password security helps maintain procedural integrity and prevents unauthorized modification of test parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eLow Noise Laboratory Operation\u003c\/span\u003e The electromagnetic drive system ensures very low noise generation, creating a quieter and more comfortable laboratory environment during prolonged operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003ePrinter Connectivity for Documentation\u003c\/span\u003e Integrated RS232 interface allows direct connection to serial printers for result printing and laboratory documentation support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-title\"\u003eHeavy-Duty Laboratory Construction\u003c\/span\u003e Robust mechanical construction is designed for continual industrial and research laboratory usage with long operational life and dependable performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"content4\" class=\"tab-content\"\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat is the primary application of the EI Model 918 Electromagnetic Sieve Shaker?\u003c\/p\u003e\n\u003cp\u003eThe EI Model 918 Electromagnetic Sieve Shaker is primarily used for accurate particle size analysis and material grading in laboratories requiring highly reproducible sieving performance. It is widely utilized in pharmaceutical laboratories, soil testing, cement analysis, food powder evaluation, aggregate testing, and industrial quality control applications.\u003c\/p\u003e\n\u003cp\u003eThe instrument delivers precise particle separation through controlled electromagnetic vibration, making it suitable for research laboratories, production monitoring, and scientific material classification procedures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eHow many sieves can the Model 918 accommodate during testing?\u003c\/p\u003e\n\u003cp\u003eThe Model 918 Electromagnetic Sieve Shaker supports up to 8 standard test sieves of 200 mm diameter and 50 mm height in a single operation. This multi-sieve configuration improves laboratory efficiency and enables simultaneous multi-level particle separation for faster analytical workflows.\u003c\/p\u003e\n\u003cp\u003eThe high-capacity design makes the instrument ideal for laboratories performing routine particle size distribution analysis and large-volume sample testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat operational modes are available in the Model 918 sieve shaker?\u003c\/p\u003e\n\u003cp\u003eThe EI Model 918 offers both intermittent and continuous shifting motion modes to suit different particle analysis requirements and material behaviors. The intermittent mode operates at 0.5-second intervals for controlled particle movement, while continuous mode supports uninterrupted sieving for efficient material separation.\u003c\/p\u003e\n\u003cp\u003eThis operational flexibility improves sieving precision and allows laboratories to optimize testing conditions for various powders, granules, and aggregates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eDoes the Model 918 provide programmable shaking intensity control?\u003c\/p\u003e\n\u003cp\u003eYes, the Model 918 features programmable electromagnetic power control with adjustable intensity settings from 1 to 20. This allows users to optimize vibration strength according to sample characteristics, mesh size, and material density for improved particle separation accuracy.\u003c\/p\u003e\n\u003cp\u003eThe programmable control system enhances repeatability and ensures reliable analytical results across different laboratory applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-question\"\u003eWhat security and connectivity features are included in the EI Model 918?\u003c\/p\u003e\n\u003cp\u003eThe EI Model 918 includes a two-tier password protection system for both administrator and user-level access, helping maintain testing integrity and secure operational settings. The instrument also features an RS232 interface for connection to serial printers including thermal and dot matrix printers.\u003c\/p\u003e\n\u003cp\u003eThese advanced features improve laboratory documentation, operational security, and workflow management in industrial and research environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the primary application of the EI Model 918 Electromagnetic Sieve Shaker?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The EI Model 918 Electromagnetic Sieve Shaker is primarily used for accurate particle size analysis and material grading in laboratories requiring highly reproducible sieving performance. It is widely utilized in pharmaceutical laboratories, soil testing, cement analysis, food powder evaluation, aggregate testing, and industrial quality control applications. The instrument delivers precise particle separation through controlled electromagnetic vibration, making it suitable for research laboratories, production monitoring, and scientific material classification procedures.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How many sieves can the Model 918 accommodate during testing?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Model 918 Electromagnetic Sieve Shaker supports up to 8 standard test sieves of 200 mm diameter and 50 mm height in a single operation. This multi-sieve configuration improves laboratory efficiency and enables simultaneous multi-level particle separation for faster analytical workflows. The high-capacity design makes the instrument ideal for laboratories performing routine particle size distribution analysis and large-volume sample testing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What operational modes are available in the Model 918 sieve shaker?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The EI Model 918 offers both intermittent and continuous shifting motion modes to suit different particle analysis requirements and material behaviors. The intermittent mode operates at 0.5-second intervals for controlled particle movement, while continuous mode supports uninterrupted sieving for efficient material separation. This operational flexibility improves sieving precision and allows laboratories to optimize testing conditions for various powders, granules, and aggregates.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the Model 918 provide programmable shaking intensity control?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, the Model 918 features programmable electromagnetic power control with adjustable intensity settings from 1 to 20. This allows users to optimize vibration strength according to sample characteristics, mesh size, and material density for improved particle separation accuracy. The programmable control system enhances repeatability and ensures reliable analytical results across different laboratory applications.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What security and connectivity features are included in the EI Model 918?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The EI Model 918 includes a two-tier password protection system for both administrator and user-level access, helping maintain testing integrity and secure operational settings. The instrument also features an RS232 interface for connection to serial printers including thermal and dot matrix printers. These advanced features improve laboratory documentation, operational security, and workflow management in industrial and research environments.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Electronics India","offers":[{"title":"Default Title","offer_id":51460978671862,"sku":"EI-DVI-EMS-918","price":229510.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/6535\/1158\/files\/Model_918_Electro_Magnetic_Sieve_Shaker_EI-DVI___02444.1760360393.386.513.jpg?v=1786599271","url":"https:\/\/scispectrum.in\/products\/model-918-electromagnetic-sieve-shaker","provider":"SciSpectrum Lab Essentials","version":"1.0","type":"link"}