ECPC70043S Parameters PH/Mv/Cond/ TDS with Cond. Cell/pH Glass Electrode and stand. Dual Display.

EUTECH
SKU:
ECPC70043S
₹92,500.00
(No reviews yet)
Condition:
New
Current Stock:
Adding to cart… The item has been added

ECPC70043S Parameters PH

Product Features ECPC70043S Parameters PH

The multi-parameter Eutech PC 700 measures pH, ORP, conductivity and temperature with a single meter. User-friendly with advanced features and a large custom-size display – perfect for research work on a budget! ECPC70043S Parameters PH
  • Large Display - Large screen in a compact footprint
  • Multi-Parameter - Meter accepts pH and Redox electrodes, in addition to Conductivity/TDS – it’s like having four meters in one!
  • Advanced Calibration - Up to 5-point push button calibration
  • Flexible Cell Constant - Selectable cell constant
  • Auto-Ranging - Auto-ranging across 5 Conductivity ranges
  • Interchangeable Probes - Easy interchangeability of probes
  • Data Storage - Non-volatile memory holds up to 100 data points
  • Built-in Holder - Integral electrode holder ECPC70043S Parameters PH

Applications

  • Water quality testing
  • Checking metal finishes
  • Solutions
  • Cooling tower water
  • Quality assurance
  • Printing fountain solutions
  • Boiler water
  • Brines
  • Drilling mud
  • Ecological studies
  • Rinse tanks
  • Ponds
  • Pollution control
  • Recirculating systems
  • Food-processing
  • Waste water
  • Industrial process systems
  • General use in laboratories
  • Titration

Specifications ECPC70043S Parameters PH

Product Specification Description
pH
Range -2.00 to 16.00 pH
Resolution 0.01 pH
Accuracy ±0.01 pH
Cal. Points Up to 5
Buffer Sets USA (1.68, 4.01, 7.00, 10.01, 12.45), NIST (1.68, 4.01, 6.86, 9.18, 12.45)
ORP
Range ±2000 mV
Rel. mV Range ±2000 mV
Resolution 0.1 mV (±199.9 mV) / 1 mV (beyond)
Accuracy ±0.2 mV (±199.9 mV) / ±2 mV (beyond)
Conductivity
Range 0.0 µS to 200.0 mS
Resolution 0.01 / 0.1 / 1 µS ; 0.01 / 0.1 mS
Accuracy ±1 % full scale
Cal. Points Automatic (84 µS, 1413 µS, 12.88 mS, 111.8 mS); maximum 1 per range; manual (5 points); maximum 1 per range
Cell Constant 0.1, 1.0, 10.0 (selectable)
TDS
Range .. to 100.0 ppt @ 0.5 fact (200.0 ppt @ 1 factor)
Resolution 0.01 / 0.1 / 1 ppm ; 0.01 / 0.1 ppt
Accuracy ±1 % full scale
Cal. Points Manual (5 points); maximum 1 per range
TDS Factor 0.40 to 1.00 (adjustable)
Temperature
Range (Meter) 0.0 to 100.0 ºC / 32.0 to 212.0 ºF
Resolution 0.1 ºC / 0.1 ºF
Accuracy ±0.5 ºC / ±0.9 ºF
Coefficient (Per ºC) 0.00 to 10.00 %
Normalization 15.0 to 30.0 ºC (adjustable)
Compensation
Type & Range Automatic with supplied cell or manual 0.0 to 100 ºC / 32.0 to 212.0 ºF, 0 to 80 ºC / 32.0 to 176.0 ºF with supplied cell
Power
Power Requirements 9 V DC adapter, 1.3 A (100/240 VAC, SMPS)