Image coming soon

EUTECH Model ECCON270043S With 4-Cell Cond. Probe CONSEN9201D K=0.530, Integral Electrode Holder & 100/240 Adapter, RS232 cable Cond/TDS/Salinity/Restivity and Tepm. Range 0 to 500ms/cm; 0 to 500ppt; 0 to 80 ppt,0 to 200mohms

₹105,500.00
(No reviews yet)
Condition:
New
Current Stock:
Adding to cart… The item has been added

EUTECH Model ECCON270043S

Product Features Featuring auto-standardization, auto-calibration and auto-ranging capabilities, the Eutech CON 2700 accepts 2-cell and 4-cell electrodes, allowing a broad range of measurement at up to ±1 % full scale accuracy. Meter comes with a multi data screen that shows Conductivity readings, temperature, electrode status, calibration points, date and time all at once.
  • Flexible Calibration - Choose auto-calibration with preset values for quick easy calibration, or manual multi-point calibration for greater accuracy
  • Auto-Standardization - Detect the exact cell constant value of your electrodes with the press of a button
  • Electrode Diagnostics - Quick, easy electrode diagnosis with the effective cell constants display
  • Quick Replatinization - Replatinization in 5 minutes with the built-in replanitization circuit
  • Enhanced Memory - Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance
  • Data Transfer - Bi-directional RS232 for easy data transfer to computer
  • Calibration Alerts - Cal-due alarm prevents out-dated calibrations
  • Continuous Monitoring - Auto-logging function for convenient continuous monitoring
  • Range Alerts - Limit alarm alerts when reading falls out of range
  • Security - Password protection for setup and calibration
  • Specifications
Product Specification Description
Conductivity
Range 0.050 µS to 500.0 mS
Resolution 0.01 / 0.1 µS ; 0.001 / 0.01 / 0.1 mS
Accuracy ±1 % full scale
Calibration Points Up to 5
Cell Constant 0.010 to 10.000
TDS EUTECH Model ECCON270043S
Range 0.050 ppm to 500 ppt (@ TDS factor 1.00)
Resolution 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt
Accuracy ±1 % full scale
Calibration Points Up to 5
Salinity
Range 0.0 to 80.0 ppt
Resolution 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt
Accuracy ±1 % full scale
Resistivity EUTECH Model ECCON270043S
Range 2.000 Ohm to 20.0 MOhm
Resolution 0.01 / 0.1 Ohm ; 0.001 / 0.1 kOhm ; 0.01 MOhm
Accuracy ±1 % full scale
Temperature
Range 0.0 to 100.0 °C / 32.0 to 212.0 °F
Resolution 0.1 °C / 0.1 °F
Accuracy ±0.3 °C / ±0.5 °F
Coefficient Linear & pure ; 0.000 to 10.000 % per °C
Normalization 15.0 to 30.0 °C / 59.0 to 86.0 °F
Compensation ATC / MTC
Others EUTECH Model ECCON270043S
Power Requirements 9 V DC adapter, 1.3 A (100/240 VAC, SMPS)