INCUBATOR REMI RHI-50 Hot air Incubator with 50 Liters capacity & Temperature setting range from RT + 5°C up to +65°C
REMI
The JAYANT Table Model Sieve Shaker Cat. No. J-91 is a precision-engineered laboratory sieve shaker designed for accurate particle size analysis, screen analysis, and dry sieving applications across research laboratories, industrial quality control departments, educational institutions, and production facilities. Built with a robust heavy-duty cast iron construction, this analytical sieve shaker delivers dependable and uniform vibratory motion for highly reproducible sieving results.
Engineered for continuous laboratory and industrial operation, the J-91 utilizes an eccentric weight-driven vibratory mechanism that generates smooth and uniform vibration across the sieve table. The balanced sieve table is mounted on specially designed helical springs, ensuring consistent particle separation efficiency while minimizing operational instability and vibration loss.
The instrument is equipped with a user-friendly front control panel featuring an ON/OFF switch, indicator pilot lamp, imported mechanical timer, and adjustable speed regulator for variable amplitude control. The adjustable vibration intensity allows operators to optimize sieving performance based on sample characteristics and analytical requirements.
Suitable exclusively for dry sieving applications, the JAYANT J-91 supports particle analysis from 4 mm down to 37 microns. The unit accommodates up to 6 JAYANT brand test sieves of 8-inch (200 mm) diameter along with upper lid and bottom receiver, making it highly suitable for particle grading, material classification, powder analysis, and industrial quality assurance workflows.
Its compact tabletop design, durable construction, easy maintenance, and precision sieving capability make the JAYANT J-91 Table Model Sieve Shaker an ideal solution for laboratories requiring reliable and efficient particle size determination.
| Parameter / Feature | Details |
|---|---|
| Product Type | Table Model Analytical Sieve Shaker |
| Model | J-91 |
| Brand | JAYANT |
| Construction | Heavy Cast Iron Unit |
| Sieving Motion | Uniform Vibratory Motion Generated Through Eccentric Weight Mechanism |
| Motion Support | Balanced Sieve Table Mounted on Helical Springs |
| Amplitude Control | Variable Amplitude Adjustable Through Front Panel Speed Regulator |
| Timer | Imported Mechanical Timer (10 Minutes to 60 Minutes) |
| Analysis Type | Dry Sieving Only |
| Particle Size Analysis Range | 4 mm to 37 Microns |
| Sieve Capacity | Maximum 6 JAYANT Test Sieves plus Upper Lid and Bottom Receiver |
| Sieve Compatibility | Up to 8 Inches (200 mm) Diameter and 2 Inches (50 mm) Height |
| Alternative Configuration | 7 Sieves of 8" Diameter with Motor and Timer |
| Power Supply | 230V AC, 50Hz |
| Power Consumption | 600 Watts |
| Net Weight | Approx. 32 kg (Without Sieves) |
| Packed Weight | Approx. 37 kg with Wooden Case Packing |
| Dimensions (L × W × H) | 476 mm × 285 mm × 687 mm |
| Packing Dimensions | 560 mm × 560 mm × 380 mm |
| Outer Size Approx. | 14" × 14" × 6.5" Height |
| Standard Accessories | Two Side Rods, Aluminium Upper Plate, Square Bar with Clamping Screws |
| Supplied Without | Test Sieves, Upper Lid, and Bottom Receiver |
| Applications | Particle Size Analysis, Powder Testing, Quality Control, Industrial Screening, Research Laboratories |
The JAYANT J-91 Table Model Sieve Shaker is engineered to provide accurate particle separation, stable vibratory performance, and long operational durability for laboratory and industrial sieving applications.
What is the primary application of the JAYANT J-91 Table Model Sieve Shaker?
The JAYANT J-91 is primarily used for accurate particle size analysis and dry sieving applications in laboratories and industrial quality control environments.
It is commonly utilized for powder analysis, material grading, raw material inspection, research studies, and production quality monitoring.
What type of sieving operation does the J-91 support?
The JAYANT J-91 is specifically designed for dry sieving operations only. It provides consistent vibratory motion for efficient separation and classification of dry particulate materials.
How does the J-91 generate vibratory motion?
The instrument uses an eccentric weight-driven mechanism connected to the motor assembly. This generates uniform vibration on the sieve table for highly reproducible sieving performance.
The balanced helical spring mounting system further improves vibration consistency and operational stability.
What is the sieve capacity of the JAYANT J-91?
The sieve shaker can accommodate a maximum of 6 JAYANT brand test sieves up to 8 inches (200 mm) diameter along with upper lid and bottom receiver.
Alternative configurations supporting 7 sieves may also be available depending on setup requirements.
Which industries commonly use the JAYANT Table Model Sieve Shaker?
The J-91 is widely used in pharmaceutical industries, chemical laboratories, food processing facilities, cement plants, mineral analysis laboratories, educational institutions, and industrial research centers.
Its precise vibration control and durable construction make it suitable for both routine laboratory testing and industrial quality assurance applications.