Jar Test Apparatus Model 1926 - 6 Samples, Digital, 10-300 RPM
In stockShips in 2–3 days
EI-DVI
The Jar Test Apparatus Model 1924 is a precision-engineered digital flocculator designed for accurate and repeatable flocculation testing in water treatment plants, environmental laboratories, wastewater treatment facilities, research institutions, and industrial quality control applications. Configured to accommodate four samples simultaneously, this laboratory jar test apparatus enables efficient comparison of coagulation and flocculation parameters during water and effluent treatment analysis.
Built for dependable laboratory performance, the Model 1924 features a high-visibility digital RPM display with precise speed control from 10 to 300 RPM. The robust stainless steel paddles ensure consistent mixing action, while adjustable paddle depth allows optimized agitation for different sample volumes and testing protocols.
The integrated digital timer system supports programmable countdown operation from 0 to 99 minutes with automatic paddle stop and audible alert functionality. Following completion, the timer automatically switches to count-up mode to simplify settling time analysis and improve workflow efficiency in routine flocculation testing.
Designed for operational convenience, the apparatus includes two programmable memory presets for storing frequently used speed and timing parameters. The flat touch-sensitive keypad improves ease of cleaning while enhancing durability in demanding laboratory environments.
To improve visibility during testing, the Jar Test Apparatus incorporates built-in white LED illumination positioned below the sample platform for clear bottom illumination of water and effluent samples. Its reliable digital controls, programmable operation, and rugged stainless steel paddle assembly make the Model 1924 an ideal solution for modern water analysis and flocculation testing laboratories.
| Feature | Details |
|---|---|
| Product Type | Digital Jar Test Apparatus / Flocculator |
| Model | 1924 |
| Number of Samples | 4 Samples |
| Speed Range | 10 – 300 RPM |
| Timer Range | 0 – 99 Minutes |
| Digital Display | LED Display for RPM Indication |
| Pre-set Programs | 2 Memory Programs |
| Control Interface | Flat Touch Sensitive Keypad |
| Paddle Material | Stainless Steel |
| Paddle Adjustment | Adjustable Paddle Depth and Spacing |
| Illumination | Built-in White LED Bottom Illumination |
| RPM Measurement | Integrated RPM Measurement Arrangement |
| Power Supply | 230V, 50Hz, Single Phase |
| Power Consumption | 100W |
| Accessories Included | Stainless Steel Paddles/Rod, Dust Cover, Instruction Manual |
| Optional Accessories | Glass Beakers |
| Warranty | 1 Year |
| Applications | Water Treatment, Effluent Testing, Wastewater Analysis, Environmental Laboratories |
The Jar Test Apparatus Model 1924 is designed to improve flocculation testing accuracy, simplify laboratory operation, and deliver reliable performance for water treatment and wastewater analysis applications.
What is the Jar Test Apparatus Model 1924 used for?
The Jar Test Apparatus Model 1924 is used for conducting flocculation and coagulation tests on water and wastewater samples. It helps laboratories and water treatment facilities determine the optimum chemical dosing conditions required for effective sedimentation, clarification, and water treatment process optimization.
This digital flocculator is widely used in water treatment plants, environmental laboratories, wastewater analysis facilities, and industrial quality control applications requiring accurate jar testing procedures.
How many samples can the Model 1924 process simultaneously?
The Jar Test Apparatus Model 1924 is designed to handle four samples simultaneously, enabling side-by-side comparison of flocculation and coagulation conditions. This improves laboratory efficiency and allows operators to evaluate multiple treatment parameters during a single testing cycle.
The four-sample configuration is ideal for routine water treatment optimization and comparative chemical dosing analysis in laboratory environments.
What is the speed range of the Jar Test Apparatus Model 1924?
The Model 1924 offers a variable paddle speed range of 10 to 300 RPM for precise control of mixing intensity during flocculation testing. The digital RPM display ensures accurate monitoring and repeatable test conditions for reliable water treatment analysis.
The wide adjustable speed range supports both rapid mixing and slow stirring processes required during coagulation and settling studies.
Does the apparatus include programmable timer and preset functions?
The Jar Test Apparatus Model 1924 includes a programmable digital timer with countdown and count-up functionality, along with two programmable memory presets for storing frequently used speed and time settings. These features improve testing consistency and operational convenience.
Automatic paddle stop and audible alerts further simplify routine laboratory workflows and settling time measurements.
What industries commonly use digital jar test apparatus systems?
Digital jar test apparatus systems are commonly used in municipal water treatment plants, wastewater treatment facilities, environmental testing laboratories, educational institutions, chemical industries, and industrial process quality control laboratories for coagulation and flocculation studies.
They are essential instruments for optimizing water clarification, chemical dosing efficiency, and sedimentation performance in modern water treatment operations.