Eutech DO 2700 Benchtop Dissolved Oxygen Meter
The Eutech DO 2700 is a benchtop dissolved oxygen, BOD and temperature meter for laboratory water analysis. It measures dissolved oxygen from 0.00 to 50.00 mg/L and oxygen saturation from 0 to 600.0%, with a specified accuracy of ±0.5% full scale. For laboratories comparing dissolved oxygen meters, the DO 2700 combines a self-stirring probe option, sample-condition compensation, stored measurement records and RS232 communication.
Manufacturer-listed applications include wastewater and water treatment, environmental studies, ecological studies and educational laboratories. Its bench format suits laboratory sample measurement; users should select a separate instrument where portable field measurement is the primary requirement.
DO measurement for laboratory and BOD workflows
The manufacturer describes the DO 2700 as suitable for BOD and dissolved oxygen applications. The ECDO270042 kit pairs the meter with an EC620SSP polarographic dissolved oxygen/BOD/temperature electrode with a self-stirring mechanism. Confirm the exact kit configuration when requesting a quotation, particularly when replacing an existing meter or probe.
Temperature, salinity and barometric pressure compensation help account for sample and measurement conditions. The instrument provides automatic calibration at 100% saturation and an independent 0% calibration, together with calibration-due reminders and configurable limit alarms.
Records and purchasing information
Up to 500 data sets can be stored with date and time stamps. Bi-directional RS232 supports transfer to a compatible computer or printer, while auto-logging supports repeated measurement records. Confirm software, computer connection and any adapter requirements before ordering.
SciSpectrum Lab Essentials supplies laboratory instruments as a reseller. For a quotation, specify DO 2700, your required probe configuration, intended sample type and any computer or printer connection requirements. The manufacturer kit reference is ECDO270042; the SciSpectrum SKU for this listing is EUT-DO-2700.
Technical information is based on the Eutech 2700 Series manufacturer brochure, pages 2, 4, 6 and 7. Use the Downloads tab for the manufacturer catalogue and SciSpectrum specification sheet.
DO 2700 Technical Specifications
| Dissolved oxygen range | 0.00 to 50.00 mg/L |
| DO resolution | 0.01 mg/L |
| DO accuracy | ±0.5% full scale |
| Oxygen saturation range | 0 to 600.0% |
| Saturation resolution / accuracy | 0.1% / ±0.5% full scale |
| Calibration | Automatic at 100%; independent 0% |
| Salinity correction | 0 to 50.0 ppt; 0.1 ppt resolution |
| Barometric pressure correction | 450 to 825 mmHg; automatic correction with built-in sensor; 1 mmHg resolution |
| Temperature range | 0.0 to 50.0 °C / 32.0 to 122.0 °F |
| Temperature resolution / accuracy | 0.1 °C / 0.1 °F; ±0.3 °C / ±0.5 °F |
| Memory | 500 data sets with date/time stamps |
| Communication | Bi-directional RS232 |
| Power requirement | 9 V DC adapter, 1.3 A; 100/240 VAC SMPS |
| Meter dimensions / weight | 17.5 × 15.5 × 6.9 cm (L × W × H); 650 g |
| Boxed dimensions / weight | 30.8 × 23.5 × 12.4 cm; 1800 g |
| Manufacturer kit reference | ECDO270042; part no. 01X543907 |
| Kit probe | EC620SSP self-stirring polarographic DO/BOD/ATC electrode |
| Applications | Wastewater and water treatment; environmental studies; ecological studies; educational laboratories |
Features and Practical Benefits
- Self-stirring probe configuration: The ECDO270042 manufacturer kit includes the EC620SSP probe with an integrated stirring mechanism for laboratory DO and BOD work.
- Sample-condition compensation: Temperature, salinity and barometric pressure compensation support measurement under varying conditions; pressure correction uses a built-in sensor.
- Two calibration levels: Automatic 100% calibration and independent 0% calibration support setup across the oxygen measurement range.
- Stored measurement records: Non-volatile memory retains up to 500 data sets with date and time stamps for later review.
- Computer and printer communication: Bi-directional RS232 provides a route for transferring readings to compatible external equipment.
- Auto-logging and reminders: Auto-logging, a calibration-due alarm and out-of-range limit alarms help organise routine measurement work.
- Protected instrument settings: Password protection is available for setup and calibration.
Manufacturer Kit Contents
The brochure lists ECDO270042 with the DO 2700 meter and EC620SSP electrode. All listed 2700 configurations include the 30X427301 RS232 cable and a 100/240 VAC power adapter. The DO configuration excludes the integral electrode holder. Confirm these contents against the quotation before purchase.
DO 2700 Frequently Asked Questions
What does the Eutech DO 2700 measure?
It measures dissolved oxygen and temperature, including oxygen saturation readings. The manufacturer lists it for laboratory dissolved oxygen and BOD applications.
What are the dissolved oxygen range and accuracy?
The DO range is 0.00 to 50.00 mg/L, with 0.01 mg/L resolution and ±0.5% full-scale accuracy. Oxygen saturation spans 0 to 600.0%, with 0.1% resolution.
Which probe is included with ECDO270042?
The manufacturer catalogue lists EC620SSP, a polarographic DO/BOD/ATC electrode with a self-stirring mechanism. Confirm the order code and probe configuration in your quotation.
Can the DO 2700 transfer readings to a computer?
Yes. It has bi-directional RS232 communication and stores up to 500 date/time-stamped data sets. Check compatible software and computer adapter requirements before ordering.
Does it compensate for salinity and air pressure?
Yes. Salinity correction covers 0 to 50.0 ppt. Automatic barometric pressure correction covers 450 to 825 mmHg using a built-in sensor; temperature compensation is also provided.
Is an electrode holder included in the DO kit?
The 2700 Series brochure states that the DO configuration excludes the integral electrode holder. The listed kit includes the self-stirring probe, RS232 cable and power adapter.
How do I request the correct DO 2700 configuration?
Share your sample type, DO/BOD workflow, required probe and computer connection needs with SciSpectrum. Reference EUT-DO-2700 and manufacturer kit ECDO270042 so the supplied configuration can be confirmed.
Product overview
Key features
Applications
Specifications
Applications
Features & benefits
Frequently asked questions
Need help selecting a Dissolved Oxygen Meters?
Tell us your application and our specialists will recommend the right model.

