The Eutech DO 700 is a benchtop dissolved oxygen and temperature meter for routine laboratory water analysis. It measures dissolved oxygen from 0 to 30 mg/L, with 0.01 mg/L resolution and ±0.5% full-scale accuracy. The manufacturer lists it for laboratories, production plants and schools where straightforward operation and a clear display are priorities.
The DO 700 displays dissolved oxygen in ppm, mg/L or percentage saturation, together with temperature. A Ready indicator helps identify stable readings, while the hold function supports recording a measurement. Non-volatile memory stores up to 100 data points for later review.
Probe and Sample-Condition Compensation
The ECDO70042S manufacturer kit includes a DO6HANDY galvanic dissolved oxygen/ATC probe, an integral electrode holder and a 100/240 VAC adapter. This configuration suits bench measurement of water samples. Confirm the required probe, cable length and accessories when requesting a quotation.
Temperature, salinity and barometric pressure compensation help account for different measurement conditions. Barometric pressure is entered manually; the meter then applies the corresponding correction. This is an important distinction when comparing the DO 700 with instruments that use a built-in pressure sensor.
Selecting a Laboratory DO Meter
The DO 700 is suitable for environmental studies, wastewater and water-treatment laboratories, ecological studies and educational work, as listed by the manufacturer. Before selecting the instrument, compare your sample concentration range, operating temperature and record-storage needs with the specifications below. For a specialised application, confirm the measurement procedure and probe suitability before purchase.
SciSpectrum Lab Essentials supplies laboratory instruments as a reseller. Reference Sci SKU EUT-DO-700 and manufacturer kit ECDO70042S in your enquiry, and share the sample type and required accessories so the configuration can be confirmed.
Sources: Eutech 700 Series manufacturer brochure, pages 2, 4, 5 and 7, and the DO 700 instruction manual. Catalogue, specification sheet and manual are available in Downloads.
DO 700 Technical Specifications
| Measurement parameters | Dissolved oxygen and temperature |
| Dissolved oxygen range | 0 to 30 mg/L |
| DO resolution | 0.01 mg/L |
| DO accuracy | ±0.5% full scale |
| Oxygen saturation range | Catalogue prints “0 to 199.9%; 300%”; confirm interpretation for your application |
| Saturation resolution / accuracy | 0.1% / ±0.5% full scale |
| Salinity correction | 0 to 50 ppt; 0.1 ppt resolution |
| Barometric pressure input | 450 to 825 mmHg; manual input; 1 mmHg resolution |
| Pressure correction method | Automatic correction using manually entered pressure |
| Temperature range | 0.0 to 50.0 °C / 32.0 to 122.0 °F |
| Temperature resolution | 0.1 °C / 0.1 °F |
| Temperature accuracy | ±0.5 °C / ±0.9 °F |
| Memory | 100 data points; non-volatile |
| Reading aids | Ready stability indicator and hold function |
| Power input | 9 V DC adapter; 100/240 VAC SMPS |
| Meter dimensions / weight | 17.5 × 15.5 × 6.9 cm (L × W × H); 650 g |
| Manufacturer kit reference | ECDO70042S; part no. 01X543501 |
| Kit probe | DO6HANDY galvanic dissolved oxygen/ATC electrode |
| Applications | Environmental studies; wastewater and water treatment; ecological studies; educational laboratories |
Features and Practical Benefits
- DO and temperature together: View the oxygen measurement with sample temperature on the large display.
- 100-point memory: Store up to 100 measurements in non-volatile memory for subsequent review.
- Ready stability indicator: Identify when the reading is stable before recording the result.
- Hold function: Hold a reading while noting the measurement.
- Sample-condition compensation: Temperature and salinity compensation, plus pressure correction using a manually entered barometric value.
- Galvanic probe configuration: The ECDO70042S kit uses the DO6HANDY dissolved oxygen/ATC electrode.
- Organised bench setup: The manufacturer kit includes an integral electrode holder and power adapter.
Manufacturer Kit Contents
The brochure lists ECDO70042S with the DO 700 meter, DO6HANDY dissolved oxygen/ATC probe, integral electrode holder and 100/240 VAC adapter. Refer to the official manual for probe maintenance and replacement parts, and confirm final contents in your quotation.
DO 700 Frequently Asked Questions
What does the Eutech DO 700 measure?
It measures dissolved oxygen and temperature. Dissolved oxygen can be displayed in ppm, mg/L or percentage saturation.
What is the DO 700 dissolved oxygen range?
The manufacturer brochure lists 0 to 30 mg/L, with 0.01 mg/L resolution and ±0.5% full-scale accuracy.
Which electrode comes with ECDO70042S?
The manufacturer kit lists the DO6HANDY galvanic dissolved oxygen/ATC electrode, an integral electrode holder and a 100/240 VAC adapter.
Does the meter automatically sense barometric pressure?
The DO 700 uses manual barometric-pressure input from 450 to 825 mmHg. It applies pressure correction using that entered value.
How many readings can the DO 700 store?
Its non-volatile memory holds up to 100 data points. A Ready indicator and hold function also help with routine measurement recording.
Where is the DO 700 commonly used?
Manufacturer-listed applications include environmental studies, wastewater and water treatment, ecological studies and educational laboratories.
How do I maintain the DO6HANDY probe?
Follow the official DO 700 manual for membrane, electrolyte, cleaning and storage procedures. Use the specified replacement parts and check the probe condition before measurement.
How can I request a DO 700 quotation?
Contact SciSpectrum with SKU EUT-DO-700, kit reference ECDO70042S, your sample type and required accessories. The supplied configuration can then be confirmed.
Product overview
Key features
Applications
Specifications
Applications
Features & benefits
Downloads
Frequently asked questions
Need help selecting a Dissolved Oxygen Meters?
Tell us your application and our specialists will recommend the right model.