The Eutech ELITEPCTS is a pocket multiparameter tester for pH, conductivity, TDS, salinity and temperature. Its large backlit graphic screen displays the selected water quality reading with temperature. A replaceable sensor, multipoint calibration and automatic temperature compensation support routine field and laboratory water checks.
Applications
- Drinking water and environmental monitoring
- Hydroponics and agriculture
- Aquaculture and aquarium water checks
- Food and beverage testing
- Pools, spas and education
| Specification | Value |
|---|---|
| Brand / model | Eutech / ELITEPCTS |
| Instrument type | Pocket multiparameter water tester |
| Parameters | pH, conductivity, TDS, salinity and temperature |
| pH range | −1.00 to 15.00 pH |
| pH resolution / relative accuracy | 0.01 pH / ±0.02 pH |
| pH calibration | Up to 3 points; USA 4.01, 7.00, 10.01 or NIST 4.01, 6.86, 9.18 buffers |
| Conductivity range | 0.00 to 20.00 mS/cm |
| Conductivity resolution | 0.1 µS/cm (0.0–200.0 µS/cm); 1 µS/cm (200–2000 µS/cm); 0.01 mS/cm (2.00–20.00 mS/cm) |
| Conductivity relative accuracy | ±1% full scale |
| Conductivity calibration | Up to 3 points |
| Conductivity reference temperature | 25.0 °C |
| TDS range | 0.00 to 10.00 ppt, depending on TDS factor |
| TDS resolution | 0.1 ppm (0.0–100.0 ppm); 1 ppm (100–1000 ppm); 0.01 ppt (0.10–10.00 ppt), as listed in manufacturer brochure |
| TDS relative accuracy | ±1% full scale |
| TDS factor / calibration | 0.40–1.00 selectable / up to 3 points |
| Salinity range / resolution | 0.00–10.00 ppt / 0.10 ppt |
| Salinity relative accuracy / calibration | ±1% full scale / 1 point |
| Temperature range / resolution | 0.0–60.0 °C / 0.1 °C; 32.0–140.0 °F / 0.1 °F |
| Temperature accuracy | ±0.6 °C at 0.0–50.0 °C; ±1.1 °C at 50.1–60.0 °C |
| Temperature compensation | Automatic (ATC) |
| Ambient operating temperature | 5–45 °C |
| Relative humidity | 5–85%, non-condensing |
| Display / keypad | Backlit graphic dot-matrix display / 4 keys |
| Power / average battery life | 4 × AAA alkaline batteries / 150 hours average |
| Protection rating | IP67 |
| Dimensions (L × W × H) | 200 × 45 × 36 mm |
| Weight | 165 g including batteries |
| Included items | Elite PCTS tester, batteries, lanyard and soft carry case |
| Replacement sensor | 01X001530, available separately |
| Availability | Enquire for availability |
- Five parameters in one pocket tester Measure pH plus conductivity, TDS or salinity with temperature for sample checks across water treatment, agriculture and aquaculture.
- Backlit graphic display The large dot-matrix screen helps operators read the selected measurement and temperature during field or production checks.
- Multipoint calibration Calibrate pH and conductivity at up to three points. Select the USA or NIST pH buffer set to suit your laboratory procedure.
- Automatic temperature compensation Integrated temperature measurement supports compensated readings. Temperature accuracy is specified separately across the 0–60 °C measurement range.
- Replaceable sensor head The separately available 01X001530 PCTS sensor supports maintenance of the same instrument when a sensor replacement is required.
- IP67 pocket design The compact instrument uses four AAA batteries and has a wide cap that can serve as a stable base.
What does the Eutech ELITEPCTS pocket water tester measure?
The Eutech ELITEPCTS measures pH, conductivity, total dissolved solids, salinity and temperature. The display shows pH, conductivity, TDS or salinity alongside temperature, allowing users to check several water quality indicators with one instrument. Manufacturer-listed applications include drinking water, environmental monitoring, food and beverage work, hydroponics, agriculture, aquaculture, aquariums, pools and spas. Select the measurement mode that matches your sample and record its unit together with the result. Conductivity, TDS and salinity use different reporting scales, so identify the required scale in your testing procedure. For buying enquiries, quote the exact ELITEPCTS model number and describe the sample and measurement range you need.
What are the ELITEPCTS measurement ranges and accuracy specifications?
The manufacturer's ELITEPCTS specification gives a pH range of −1.00 to 15.00 with 0.01 pH resolution and ±0.02 pH relative accuracy. Conductivity extends to 20.00 mS/cm, while TDS reaches 10.00 ppt depending on the selected TDS factor. Salinity covers 0.00 to 10.00 ppt. Conductivity, TDS and salinity each have a relative accuracy specification of ±1% full scale. The temperature measurement range is 0.0 to 60.0 °C, with 0.1 °C resolution. Temperature accuracy is ±0.6 °C through 50.0 °C and ±1.1 °C from 50.1 to 60.0 °C. Compare these limits with the expected sample values before selecting the tester for a routine method.
How is the Eutech ELITEPCTS calibrated for pH and conductivity?
ELITEPCTS supports calibration at up to three points for pH and conductivity. Its pH buffer selection includes the USA set of 4.01, 7.00 and 10.01, and the NIST set of 4.01, 6.86 and 9.18. Choose the buffer family used by your procedure and prepare appropriate standards for the expected samples. TDS also supports up to three calibration points, and salinity uses one point. The manufacturer's brochure lists compatible buffer and conductivity standard ordering codes in the Downloads document. Confirm the standards required for your procedure when requesting a quotation. The base ELITEPCTS package contains the tester, batteries, lanyard and soft carry case, so plan calibration consumables separately.
How do TDS settings and temperature affect ELITEPCTS water testing?
The ELITEPCTS provides a selectable TDS factor from 0.40 to 1.00, and the manufacturer qualifies its TDS range as dependent on this factor. Record the selected factor in your procedure so results from different operators or instruments can be compared on the same basis. The tester provides automatic temperature compensation and displays temperature with the selected water quality reading. Its conductivity reference temperature is 25.0 °C. Distinguish sample temperature measurement from the ambient operating environment when planning field work. The sample temperature specification extends to 60.0 °C, while the specified ambient operating range is 5 to 45 °C and relative humidity is 5 to 85%, non-condensing.
What is included with ELITEPCTS, and can its sensor be replaced?
The manufacturer lists the ELITEPCTS base tester with batteries, a lanyard and a soft carry case. It operates on four AAA alkaline batteries with an average stated battery life of 150 hours. Its replacement PCTS sensor is separately identified as part number 01X001530. When ordering a sensor, provide the ELITEPCTS catalogue number to help confirm the correct replacement. The manufacturer also offers an ELITEPCTSKIT package containing calibration solutions, with its own ordering code. Check the quoted package against your requirements for buffers, conductivity standards and sensor maintenance. SciSpectrum lists this ELITEPCTS tester as Enquire for availability, so request current availability and any additional consumables with your enquiry.
Product overview
Key features
Applications
Specifications
| Brand / model | Eutech / ELITEPCTS |
| Instrument type | Pocket multiparameter water tester |
| Parameters | pH, conductivity, TDS, salinity and temperature |
| pH range | −1.00 to 15.00 pH |
| pH resolution / relative accuracy | 0.01 pH / ±0.02 pH |
| pH calibration | Up to 3 points; USA 4.01, 7.00, 10.01 or NIST 4.01, 6.86, 9.18 buffers |
| Conductivity range | 0.00 to 20.00 mS/cm |
| Conductivity resolution | 0.1 µS/cm (0.0–200.0 µS/cm); 1 µS/cm (200–2000 µS/cm); 0.01 mS/cm (2.00–20.00 mS/cm) |
| Conductivity relative accuracy | ±1% full scale |
| Conductivity calibration | Up to 3 points |
| Conductivity reference temperature | 25.0 °C |
| TDS range | 0.00 to 10.00 ppt, depending on TDS factor |
| TDS resolution | 0.1 ppm (0.0–100.0 ppm); 1 ppm (100–1000 ppm); 0.01 ppt (0.10–10.00 ppt), as listed in manufacturer brochure |
| TDS relative accuracy | ±1% full scale |
| TDS factor / calibration | 0.40–1.00 selectable / up to 3 points |
| Salinity range / resolution | 0.00–10.00 ppt / 0.10 ppt |
| Salinity relative accuracy / calibration | ±1% full scale / 1 point |
| Temperature range / resolution | 0.0–60.0 °C / 0.1 °C; 32.0–140.0 °F / 0.1 °F |
| Temperature accuracy | ±0.6 °C at 0.0–50.0 °C; ±1.1 °C at 50.1–60.0 °C |
| Temperature compensation | Automatic (ATC) |
| Ambient operating temperature | 5–45 °C |
| Relative humidity | 5–85%, non-condensing |
| Display / keypad | Backlit graphic dot-matrix display / 4 keys |
| Power / average battery life | 4 × AAA alkaline batteries / 150 hours average |
| Protection rating | IP67 |
| Dimensions (L × W × H) | 200 × 45 × 36 mm |
| Weight | 165 g including batteries |
| Included items | Elite PCTS tester, batteries, lanyard and soft carry case |
| Replacement sensor | 01X001530, available separately |
| Availability | Enquire for availability |
Applications
Features & benefits
Downloads
Frequently asked questions
Need help selecting a Multiparameter Meters?
Tell us your application and our specialists will recommend the right model.