Lovibond BD 600 Respirometric BOD Measurement System with 6 Sensors (Part No. 2444460)
The Lovibond BD 600 is a respirometric system for determining Biochemical Oxygen Demand (BOD) in wastewater. It runs six samples at once using mercury-free electronic pressure sensors, and is designed for plant process control or as a secondary test alongside the dilution method.
Sample preparation is simple: add the sample to the bottle, add nitrification inhibitor and fit the sensor head. Measurements are taken and stored automatically at fixed intervals over a user-selected period of 1 to 28 days, so operators do not need to be present when a test finishes. An automatic start function ensures all measurements are taken at an equal sample temperature, keeping conditions consistent across readings.
Results are shown directly in mg/L BOD on a large backlit graphic display, which can also plot the BOD curve for each sample so trends are easy to read. Each sensor head has an integrated LED to confirm which sample is being displayed, and samples can be given an identification code for traceability. Data can be exported through USB or saved to an SD card.
Seven measuring ranges from 0–40 mg/L up to 0–4000 mg/L BOD cover everything from treated effluent to high-strength industrial wastewater. A supplied remote control lets operators view data through a glass-door incubator without opening it, which helps keep sample temperature stable.
Technical Specifications
| Parameter / Feature | Details |
|---|---|
| Product Type | Respirometric BOD Measurement System |
| Brand | Lovibond (Tintometer Group) |
| Model / Part Number | BD 600 / 2444460 |
| Measuring Principle | Manometric; mercury-free; electronic pressure sensor |
| Measuring Stations | 6 |
| Measuring Ranges | 0–40, 0–80, 0–200, 0–400, 0–800, 0–2000, 0–4000 mg/L BOD |
| Measurement Time | User-selectable, 1 to 28 days |
| Storage Interval | Hourly (day 1), every 2 hours (day 2), once daily (days 3–28) |
| Display | Backlit graphic display |
| Interfaces | USB, SD card |
| Autostart | Yes |
| Clock | Real-time clock and date |
| Power Supply | 100–240 V / 50–60 Hz; 3 alkaline-manganese batteries (size C) |
| IP Rating | IP 51 |
| Compliance | CE; EMC according to DIN EN 61326 |
| Dimensions | 181 × 230 × 375 mm |
| Weight | 4.1 kg (5.775 kg complete with bottles, batteries and stirring unit) |
| Scope of Delivery | BD 600 with 6 sensor heads, control unit with batteries, power supply with Y-cable, inductive stirring unit, 6 sample bottles, 6 rubber gaskets, 6 magnetic stirring rods, 50 ml potassium hydroxide solution 45%, 50 ml nitrification inhibitor, overflow measuring flasks 157 ml and 428 ml, remote control, manual |
Specifications from the Lovibond BD 600 datasheet (Part No. 2444460). A temperature-controlled incubator is required for testing and is not included.
Core Features & User Benefits
The BD 600 reduces the hands-on time of BOD testing and makes results easier to interpret, while keeping measurement conditions consistent across all six samples.
- Six Samples in Parallel Six measuring stations let you run replicates or different samples in one batch.
- Mercury-Free Pressure Sensors Electronic pressure sensors replace mercury manometers for safer, cleaner operation.
- Unattended Measurement Readings are logged automatically over 1 to 28 days, so there is no need for weekend visits to the lab.
- Automatic Start Ensures all measurements are taken at an equal sample temperature, removing a common source of error.
- Graphic BOD Curves The large backlit display shows mg/L BOD directly and plots the BOD curve for each sample.
- Sample Identification and LED Indicators Assign an ID to each sample; an LED on each sensor head confirms which sample is on screen.
- USB and SD Card Data Export Transfer results to a PC or store them on an SD card for records and reporting.
- Remote Control View data through a glass incubator door without opening it and disturbing the temperature.
Frequently Asked Questions (FAQ)
How does the BD 600 measure BOD?
It uses the respirometric (manometric) principle. As microorganisms consume oxygen in the closed sample bottle, the carbon dioxide produced is absorbed by potassium hydroxide, and the resulting pressure drop is measured by an electronic sensor and shown as mg/L BOD.
Can it replace the dilution method?
Lovibond positions the BD 600 for process control or as a secondary test to the dilution method. Where a regulator specifies the dilution method, for example IS 3025 (Part 44) for BOD in India, keep using that method for compliance reporting.
What measuring ranges are available?
Seven ranges: 0–40, 0–80, 0–200, 0–400, 0–800, 0–2000 and 0–4000 mg/L BOD. The range is set by the sample volume, measured with overflow flasks; 157 ml and 428 ml flasks are supplied, and other sizes are available as accessories.
Is an incubator needed?
Yes. Sample bottles must be kept at a constant temperature during the test, so a temperature-controlled (BOD) incubator is required. It is not included with the BD 600.
What is included in the box?
The BD 600 with 6 sensor heads, control unit with batteries, power supply with Y-cable, inductive stirring unit, 6 sample bottles, gaskets and stirring rods, potassium hydroxide solution, nitrification inhibitor, two overflow measuring flasks, remote control and manual.
Catalogue & Datasheet
Lovibond BD 600 Datasheet (Part No. 2444460)
Official Lovibond datasheet covering measuring ranges, technical data, scope of delivery and accessory part numbers.
Download Catalogue (PDF)PDF, 0.2 MB. Manufacturer document from Lovibond (Tintometer Group). For a quotation or configuration advice, contact SciSpectrum.
Product overview
Key features
Applications
Specifications
Applications
Features & benefits
Downloads
Frequently asked questions
Need help selecting a BOD Measurement Systems?
Tell us your application and our specialists will recommend the right model.