Model 1602 EI-DVI Microprocessor EC/TDS/Salinity/Temp Meter | 1000 Sample Storage

EI-DVI
SKU:
EI-MTP-1602
₹43,542.00 (Including GST)
(No reviews yet)
Current Stock:
Adding to cart… The item has been added

Model 1602 EI-DVI Microprocessor Based EC/TDS/SAL Meter – Simultaneous Multi-Parameter Analysis

The Model 1602 EI-DVI Microprocessor Based EC/TDS/SAL Meter is an advanced, solid-state laboratory instrument engineered specifically for comprehensive water quality analysis. This robust multi-parameter meter utilizes elite microprocessor control systems to deliver simultaneous and accurate measurement of four critical analytical values: Conductivity (Cond), Total Dissolved Solids (TDS), Salinity (Sal), and Temperature (Temp). Built for continuous operational ease in both demanding laboratory environments and variable field testing settings, the Model 1602 provides high precision, repeatable data tracking, and expansive internal storage infrastructure.

Designed to optimize data handling in complex fluid applications, the meter includes an intuitive built-in LCD display panel that presents all four parameters concurrently, saving operators time and avoiding complex configuration tracking. It features an integrated Auto Ranging framework that automatically selects the appropriate measurement scale to match sample concentrations perfectly, ensuring absolute readout resolution whether checking pure water works metrics or dense chemical effluents. Additionally, users can apply customizable calculation coefficients up to 1000, offering superior architectural flexibility for specialized calibration curves and proprietary calculation requirements.

For data management efficiency, the Model 1602 incorporates a non-volatile 1000 sample storage facility, allowing users to collect extensive series of measurements without the distraction of manual logging. To support long-term reporting timelines, historical quality control, and strict regulatory compliance verification, the instrument features full PC compatibility for a smooth data connection. Stored results can be quickly synchronized with external PC software networks for automated archiving, tracking, and graphing workflows.

Technical Specifications

Feature / Parameter Details
Model Number 1602 EI-DVI
Product Type Microprocessor (µP) Based EC/TDS/SAL Meter
Core Parameters Monitored Conductivity (Cond), Total Dissolved Solids (TDS), Salinity (Sal), Temperature (Temp)
Visual Interface Concurrent LCD Display Panel (Shows all four parameters simultaneously)
Ranging Framework Automated Auto Ranging Facility
Co-efficient Application Bounds Programmable up to 1000 for specialized calibrations
Internal Memory Capacity Integrated 1000 sample storage facility
External PC Connectivity Yes, PC connection enabled for long-term data transfer
Data Management Software Available at extra cost (Not included with the standard factory unit)
Manufacturer Brand EI-DVI
Operational Application Suitable for high-precision laboratory testing and versatile field environments

Core Features & User Benefits

  • Microprocessor-Driven Processing Core Utilizes state-of-the-art microprocessor technology to automate complex measurement math, speeding up testing stabilization times and guaranteeing reliable result reproducibility.
  • Four-in-One Concurrent LCD Readout Displays Conductivity, TDS, Salinity, and Temperature calculations at the same time, preventing user configuration fatigue and eliminating the need to cycle through separate menu screens.
  • Intelligent Scale Auto Ranging Automatically scans solution densities to find the correct measurement scale layout, maximizing precision during field analysis without requiring manual range inputs.
  • Expansive 1000 Sample Storage Matrix Retains massive test records safely in internal data buffers, allowing operators to complete high-volume sampling runs smoothly without immediate manual recording steps.
  • Flexible Coefficient Expansion Up to 1000 Supports extensive calculation modifier adjustments up to 1000, empowering chemical labs to customize analytical scaling for proprietary or high-concentration sample types.
  • Compliant PC Connection Interface Enables streamlined digital data synchronization with office hardware, simplifying the record-keeping required to pass strict commercial regulatory audits.
  • Dual Lab and Field Setting Utility Housed in a resilient, compact chassis that adapts smoothly to both clean laboratory testing spaces and rigorous outdoor field measurement runs.

Frequently Asked Questions & Search Engine Optimization Strategy

What parameters can the Model 1602 Microprocessor Meter measure concurrently?

The Model 1602 Microprocessor EC/TDS/SAL Meter provides simultaneous, high-precision measurement of four critical parameters: Conductivity, Total Dissolved Solids (TDS), Salinity, and Temperature. This comprehensive multi-parameter water quality analysis system displays all calculations on a centralized concurrent LCD screen.

By capturing all primary solution attributes in a single measurement sweep, it eliminates cross-contamination risks and reduces processing times across industrial quality control environments and research laboratories.

How does the integrated Auto Ranging framework on the Model 1602 improve testing accuracy?

The Model 1602 Microprocessor EC/TDS/SAL Meter features an intelligent Auto Ranging capability that automatically selects the correct scale based on sample density. This feature delivers high precision across changing sample types without requiring manual operator configurations.

This automated feature removes range configuration errors, ensuring reliable data resolution when analyzing both high-purity water systems and concentrated industrial runoff.

How many water samples can the internal memory data logger store?

The Model 1602 Microprocessor EC/TDS/SAL Meter features a substantial non-volatile 1000 sample storage facility for automated data logging. This internal memory array allows researchers to log massive testing series without the interruption of manual reporting sheets.

It helps field operators perform high-frequency measurements consecutively, protecting data integrity until a complete review can be performed.

Can I export stored water testing results from the Model 1602 to a computer?

Yes, the Model 1602 Microprocessor EC/TDS/SAL Meter includes PC connection compatibility for long-term analysis and technical data transfer. It helps managers move records safely into compliance software, though the data management application is sold at an extra cost.

This physical connection ensures laboratory workflows remain aligned with modern electronic record keeping and reporting standards.

What is the advantage of the programmable co-efficient application parameter up to 1000?

The Model 1602 Microprocessor EC/TDS/SAL Meter supports custom coefficient applications up to 1000 to maximize software conversion range utility. This calibration feature provides exceptional analytical calculation flexibility when monitoring non-standard samples or specialized water quality matrix variations.

This structural adaptation is essential for chemical engineering sectors and specialized industrial plants that deal with proprietary fluid mixes.